Suggested directory name is:

Software Installation

GENERAL INFORMATION

The Panel-Tec DN3000 Configuration Editor Software Program is designed to operate on an IBM or compatible computer running MS-DOS 3.3 or higher.

While the Configuration Editor Software Program will run under “WINDOWS 3.1” in most configurations, it is not recommended. As of this date, no problems have been reported running the software under “WINDOWS 95”.

The configuration editor software will default during start-up to using “COMM 1” unless changed using the OPTIONS menu. This may conflict with a mouse driver program and prevent up/down loading configuration information to the DN-3000 interface unit.

INSTALLATION

Place the supplied program disk into drive “A” (or B).

At the MS-DOS prompt, C:> type in A: (or B:) and then press the “ENTER” key.

When the “A” (or B) prompt appears, A:> type in “INSTALL” and press the “ENTER” key.

The following message will appear;

DN3000 Configuration Editor Installation Program

Enter the drive where the editor is to be installed ==>

Enter “C” (or any other hard drive you care to use), then press the “ENTER” key.

A new message will appear:

Enter the sub-directory on drive C to install the editor into ==>

DN3000

The next message to appear before the installation is started is:

The Editor will be installed from “A” to “C:\DN3000”

Is this correct (Y/N) ?

If the above information is correct, push the “Y” key, then the “ENTER” key and the software will be installed. The last message to appear will be:

Installation Complete.

Enter “DN3000” to run the configuration Editor

C:\DN3000>

2

Image 8
Contents DN-3000 Page Warranty & Notices WarrantyTable of Contents Application Notes Motor Drives Page Introduction IntroductionGeneral Information Software InstallationInstallation Software Information Software START-UPCreating Project Files Creating a Project FileProject Types Additional Project Menu Sub-Headings Device Profile DeviceNet to PLCs or DevicesDevicenet to Plcs or Devices DeviceNet Host to Multi-Dropped Serial PLCs Example ApplicationsDeviceNet Host to Serial PLC with Pass-Through Connection Multiple DN-3000s with Different PLC or Device Types Configuring Port #1, Devicenet DeviceNet to PLCs or Devices Edit MenuMAC ID of DN3000 Configuring Port #2 Plcs or Devices PLC/Device ProtocolWire RS422 or RS485 Communications Configuring Port # 3 Passthrough Intermessage Time-OutData Configuration Use I/O DataUse Command Block Use DiagnosticsOutput Data Size Output DataInput Data Size Input DataOutput Data Table Use Output Word PLC/Device AddressFile Number Allen-Bradley PLCs only Register NumberInput Data Table Use Input Word PLC/DeviceAddressCommand Block DeviceNet to Motor Drives Devicenet to Motor DrivesDeviceNet Host to Serial Motor Drive DeviceNet Host to Multi-Dropped Serial Motor DrivesMultiple DN-3000s with Different Motor Drive Types DeviceNet to Motor Drives Edit Menu MAC ID of DN3000 Configuring Port # 2 Motor Drives Motor Drive TypeMinimum Delay Between Messages Data Configuration Use Command Block Input Data Size Output Data Table Motor Drive Address Parameter NumberInput Data Table Use Input Word Word Motor Drive Address Command Number Word Parameter Data write command onlyWord Motor Drive Address Result Code Command Number Word Returned Parameter Data read command onlyUpper Link Configuration Mitsubishi Drives Only Operation of the Link SwitchException Table Mitsubishi Drives Only Transferring Project Files Transferring Project FilesTransfer Options Download Project to DN3000Upload Project from DN3000 VerifySET Directory Options SettingsOptions Settings Current Directory Path Graphic Area SET COM Port Default Options SET Printer OptionsLoad Options from Disk Save Options to DiskTechnical Information Power RequirementsPhysical Dimensions Switch # Normal Off Configuration Diagnostic DIP Switch SettingsVisual LED Indicators Flashes followed by a pause DN-3000 Troubleshooting InformationFlashes followed by a pause Invalid DIP Switch Setting Registers Accessed Application Notes PLCs and DevicesALLEN-BRADLEY PLC 5, SLC500 and Micrologix Plcs Protocols SupportedLink Adapter Requirement Idec MICRO-3 PlcsIdec FA Series Plcs Memory Address PLC Registers Accessed Koyo / PLC Direct 205 Series PlcsKoyo / PLC Direct / TI 305 Series Plcs Mitsubishi FX Series Plcs Modicon Plcs and Modbus DevicesOmron Plcs RTS ControlProtocol Information Pass-Through PortSquare D Model 100-700 Plcs Passthrough Port NoteWestinghouse Plcs Toshiba EX and M Series PlcsToshiba T Series Plcs Drive Parameter Numbers Assigned By Panel-Tec Application Notes Motor DrivesBaldor Motor Drives Configuring a Baldor Drive For Serial Communications Drive Addresses Assigned By Panel-TecConfiguring a Woods Drive For Serial Communications Mitsubishi Motor DrivesWoods Motor Drives Yaskawa Motor DrivesCable Diagrams DN3000 Configuration CableAllen Bradley Solder EndGE Fanuc 90/20, 30 GE Fanuc DN3000Idec Koyo/PLC Direct Mitsubishi FX Series MitsubishiModicon ModiconOmron Host LinkSiemens S7 Square D TSX07Simatic TI5 Series TI5 232 Port DN3000Toshiba Toshiba DN3000Baldor Motor Drives BaldorMitsubishi Motor Drives Woods Motor Drives Yaskawa Motor Drives DeviceNet Cable DeviceNet DN3000