ICP DAS USA DB25, 100-700 PLCS, DN-3000 user manual Software Information, Software START-UP

Page 9

Software Information

SOFTWARE START-UP

To start the DN-3000 Configuration Editor program. First start your computer and at the MS-DOS prompt; C:> type in “CD\DN3000” (to change the directory) then press the ENTER key. At the next MS-DOS prompt; C:\DN3000>, type in “DN3000” and press the ENTER key to start the Configuration Editor Software Program.

Upon starting of the configuration software program, the first screen to appear will be the “Support Information Page”, shown below.

After pressing the computer’s ENTER key, the support information page will disappear. Use the computer’s LEFT/RIGHT arrow keys and move the highlighted bar (very top of the screen) between the four (4) main system selection headers. To select any one of these main selection headers, place the highlight bar around that desired heading and then press the computer’s ENTER key. Below is a brief description of the main project header and each internal subheading; NOTE: These brief descriptions listed are as the system starts without any projects opened or new projects created.

Selecting PROJECT opens a menu with the following options:

OPEN allows you to open any saved project file. NEW allows you to create a new project file.

DOS SHELL allows you to exit to MS-DOS without closing the DN-3000 Configuration Editor Program and return to the Configuration Editor Program by typing in EXIT and then pressing the ENTER key.

QUIT allows you to exit the Configuration Editor Program.

3

Image 9
Contents DN-3000 Page Warranty Warranty & NoticesTable of Contents Application Notes Motor Drives Page Introduction IntroductionSoftware Installation InstallationGeneral Information Software START-UP Software InformationCreating a Project File Creating Project FilesProject Types Additional Project Menu Sub-Headings DeviceNet to PLCs or Devices Devicenet to Plcs or DevicesDevice Profile Example Applications DeviceNet Host to Serial PLC with Pass-Through ConnectionDeviceNet Host to Multi-Dropped Serial PLCs Multiple DN-3000s with Different PLC or Device Types DeviceNet to PLCs or Devices Edit Menu Configuring Port #1, DevicenetMAC ID of DN3000 PLC/Device Protocol Configuring Port #2 Plcs or DevicesWire RS422 or RS485 Communications Intermessage Time-Out Configuring Port # 3 PassthroughUse I/O Data Data ConfigurationUse Diagnostics Use Command BlockOutput Data Size Output DataInput Data Input Data SizeOutput Data Table PLC/Device Address Use Output WordFile Number Allen-Bradley PLCs only Register NumberInput Data Table PLC/DeviceAddress Use Input WordCommand Block Devicenet to Motor Drives DeviceNet to Motor DrivesDeviceNet Host to Multi-Dropped Serial Motor Drives DeviceNet Host to Serial Motor DriveMultiple DN-3000s with Different Motor Drive Types DeviceNet to Motor Drives Edit Menu MAC ID of DN3000 Motor Drive Type Configuring Port # 2 Motor DrivesMinimum Delay Between Messages Data Configuration Use Command Block Input Data Size Output Data Table Parameter Number Motor Drive AddressInput Data Table Use Input Word Number Word Parameter Data write command only Word Motor Drive Address CommandWord Motor Drive Address Result Code Command Number Word Returned Parameter Data read command onlyOperation of the Link Switch Upper Link Configuration Mitsubishi Drives OnlyException Table Mitsubishi Drives Only Transferring Project Files Transferring Project FilesDownload Project to DN3000 Transfer OptionsUpload Project from DN3000 VerifyOptions Settings Options SettingsSET Directory Current Directory Path Graphic Area SET COM Port SET Printer Options Default OptionsLoad Options from Disk Save Options to DiskPower Requirements Physical DimensionsTechnical Information DIP Switch Settings Visual LED IndicatorsSwitch # Normal Off Configuration Diagnostic DN-3000 Troubleshooting Information Flashes followed by a pause Invalid DIP Switch SettingFlashes followed by a pause Application Notes PLCs and Devices Registers AccessedALLEN-BRADLEY PLC 5, SLC500 and Micrologix Plcs Protocols SupportedIdec MICRO-3 Plcs Idec FA Series PlcsLink Adapter Requirement Koyo / PLC Direct 205 Series Plcs Memory Address PLC Registers AccessedKoyo / PLC Direct / TI 305 Series Plcs Modicon Plcs and Modbus Devices Mitsubishi FX Series PlcsOmron Plcs RTS ControlPass-Through Port Protocol InformationPassthrough Port Note Square D Model 100-700 PlcsToshiba EX and M Series Plcs Toshiba T Series PlcsWestinghouse Plcs Application Notes Motor Drives Baldor Motor DrivesDrive Parameter Numbers Assigned By Panel-Tec Drive Addresses Assigned By Panel-Tec Configuring a Baldor Drive For Serial CommunicationsMitsubishi Motor Drives Configuring a Woods Drive For Serial CommunicationsWoods Motor Drives Yaskawa Motor DrivesDN3000 Configuration Cable Cable DiagramsSolder End Allen BradleyGE Fanuc DN3000 GE Fanuc 90/20, 30Idec Koyo/PLC Direct Mitsubishi Mitsubishi FX SeriesModicon ModiconHost Link OmronSiemens S7 TSX07 Square DTI5 232 Port DN3000 Simatic TI5 SeriesToshiba DN3000 ToshibaBaldor Baldor Motor DrivesMitsubishi Motor Drives Woods Motor Drives Yaskawa Motor Drives DeviceNet DN3000 DeviceNet Cable