Dialogic SS7G22, SS7G21 manual SS7 Serial Interface Connector Aux on SPCI2S

Page 37

Dialogic® SS7G21 and SS7G22 Signaling Servers Hardware Manual Issue 7

Figure 8. SS7 Serial Interface Connector (Aux on SPCI2S)

T 1 / E 1

 

V . 1 1

P o r t s

 

P o r t s

 

 

 

 

 

 

L 4

L 3

A U X

The SS7 serial interface ports on the SPCI2S are designated as SELV. Install the ferrite clamp(s), provided with this product, on each SS7 serial interface port cable, close to the connector backshell, to ensure the EMC performance of the product. The connector pinout and signal assignment is given in Table 6.

Table 6. SS7 Serial Interface Ports (Dual V.11) Connector Pinouts

Pin No

Direction

 

Function

 

 

 

1

 

Chassis ground

 

 

 

 

2

Output

V.11

Transmit inverted clock Port B

 

 

 

 

3

Output

V.11

Transmit clock Port B

 

 

 

 

4

Output

V.11

Transmit inverted data Port B

 

 

 

 

5

Output

V.11

Transmit true data Port B

 

 

 

 

6

Input

V.11

Receive inverted clock Port B

 

 

 

 

7

Input

V.11

Receive clock Port B

 

 

 

 

8

Input

V.11

Receive inverted data Port B

 

 

 

 

9

Input

V.11

Receive true data Port B

 

 

 

10

 

Signal ground

 

 

 

11 to 18

 

No connection

 

 

 

 

19

Output

V.11

Transmit inverted clock Port A

 

 

 

 

20

Output

V.11

Transmit clock Port A

 

 

 

 

21

Output

V.11

Transmit inverted data Port A

 

 

 

 

22

Output

V.11

Transmit true data Port A

 

 

 

 

23

Input

V.11

Receive inverted clock Port A

 

 

 

 

24

Input

V.11

Receive clock Port A

 

 

 

 

25

Input

V.11

Receive inverted data Port A

 

 

 

 

26

Input

V.11

Receive true data Port A

 

 

 

 

The SS7 serial interface ports may be clocked either by an internally generated clock or by an externally applied clock. In both cases, the same clock is used for both the Transmit data and the Receive data.

For internal clock operation, use the Transmit clock pins and make no connection to the Receive clock pins on the D-type connector. For external clock operation, connect the clock source to the Receive clock pins on the D-type connector and make no connection to the Transmit clock pins.

37

Image 37
Contents Dialogic SS7G21 and SS7G22 Signaling Servers Publication Date January Document Number 05-2300-007, Issue Contents Index FiguresTables Date Issue No DescriptionRevision History Part 1 User’s Guide Qualified Service Technician Operations If AC Power Supplies are Installed Mains AC Power Disconnect If DC Power Supplies are Installed Isolation Page Purpose IntroductionProducts SS7 Signaling Boards Power SuppliesServer Board Hard Disk DriveCooling Ethernet PortsRelated Information Product Applicability ApplicabilityProduct ID Description DC Power Supply Module Product SpecificationAC Power Supply Module Signaling LinksSS7 Serial Interfaces PCM InterfaceEthernet Interfaces Controls and Indicators Alarm OutputsSerial Port COM2 Activity/Fault LED green/amber MNR Alarm LED amber PWR Alarm LED amberID switch Visual Indicators on the Ethernet PortsEnvironmental Specifications Physical SpecificationsProduct Reliability Calculated Product ReliabilityProduct Specification Specifications Demonstrating Compliance Safety Compliance Regulatory Specifications and DeclarationsElectromagnetic Compatibility EMC US ICKCNNANSS7HDP Telecommunications ComplianceDeclarations of the Manufacturer or Importer Declaration of ConformityNo D0006 Česky FCC Part 68 Statement USA FCC Part 15 ElectroMagnetic Compliance Statement USATelecommunications Notice Australia / New Zealand Telecommunications Attachment Notice CanadaTelecommunications Notice Taiwan 2 EMC Installation of Cables SafetyEssential Compliance Information Further InformationProduct Environmental Information Regulatory Specifications and Declarations Overview Hardware DescriptionFeature Description More Information Front Panel Control, Indicator and Switch Function SummaryFront Panel Description Informatio Back PanelRack Mounting Options Safety Ground Studs for Earthing DC Power Input Terminal BlockAC Power Input InterfacesSS7 Serial Interface Ports PCM Interface Ports Connector PinoutsPin No Direction Function SS7 Serial Interface Ports Dual V.11 Connector Pinouts SS7 Serial Interface Connector Aux on SPCI2SEthernet Interfaces Connectors Serial Port COM2 Connector Ethernet Interface Connector PinoutsPin No Description AlarmsPart 2 Service Technician’s Guide Page Qualified Service Technician Operations If AC Power Supplies are Installed Mains AC Power Disconnect If DC Power Supplies are Installed Isolation Page Tools and Supplies Needed Tools and Supplies NeededTools and Supplies Needed Installation Overview Product Installation and Hot-Swap ActionsPower Supply Related Actions Safety Ground Studs, Conductor Installation Replacement of Power Supply Module in AC ProductsDC Power Supply Module, Initial Connections DC Power Supply Module Terminal Block AC-input Power Supply Cage, Connection DC Power Supply Module, Transferring ConnectionsProduct Installation and Hot-Swap Actions Hard Disk Drive HDD Replacement Unlocking and Removing an AC Power Supply ModuleFiles Backed Up to the syslog Subdirectory at Startup Backing up the System ConfigurationReplacing the Hardware File Type DescriptionReplacing the Hard Disk Drive Restoring the System ConfigurationProduct Installation and Hot-Swap Actions Working Inside the Product Safety Before Removing the Top CoverRemoving and Installing the Top Cover Top Cover Removal and Installation Internal Product Layout Preparing Spci Signaling Boards for Installation in SS7G21 10.5 SS7 Signaling BoardsMajor Components in an SS7G21 and SS7G22 Chassis SS7G21 VariantsD1W D2W Position D3W / Q3W Setting Positions Q1W Q2W Board Boards SwitchQuantity of Boards Variant Suffix Board Position JumpersBoards Position Switch 00W H1W H2W H3W Setting Installing or Replacing an SS7 Signaling BoardInstalling and Replacing an SS7 Signaling Board CT Bus Cable Notes Replacing the Back-up BatteryVarning Working Inside the Product International Warnings International Warnings Avertissements Français Avertissements Français suite Warnung Deutsch Warnung Deutsch Fortsetzung Avvertenza Italiano Avvertenza Italiano continua Advertencia Español Advertencia Español continuación Part Number Reference Operating Mode IDsProduct ID Description SS7G21 and SS7G22 Product IDs Protocol Module IDsExpansion Options or Spare Assemblies AccessoriesLinux Software Distribution Software Licensing InformationGNU C Library Software Licensing Information Connectors on the SPCI2S Signaling Board Connecting to V.11 V.35-Compatible SS7 LinksAppendix a CablingConnecting an SPCI2S to a Nortel DMS100 Connecting an SPCI2S to an M34 Block ConnectorConnecting an SPCI2S to an Inet Tester Clocking Configuring the SIU SPCI2S to Operate on V.11 PortsSPCI2S/SIU Generates Clocking SPCI2S/SIU Receiving ClockAppendix a CT Bus GlossaryGlossary FCC IndexMtbf Switches