CY7C64215
Table 5. Units of Measure (continued) |
|
| |
|
|
|
|
Symbol | Unit of Measure | Symbol | Unit of Measure |
μV | microvolts | s | sigma: one standard deviation |
μVrms | microvolts | V | volts |
Absolute Maximum Ratings
Table 6. Absolute Maximum Ratings
Parameter | Description | Min | Typ | Max | Unit | Notes |
|
TSTG | Storage Temperature | – | +100 | °C | Higher storage temperatures |
| |
|
|
|
|
|
| reduces data retention time. |
|
TA | Ambient Temperature with Power Applied | 0 | – | +70 | °C |
|
|
Vdd | Supply Voltage on Vdd Relative to Vss | – | +6.0 | V |
|
| |
VIO | DC Input Voltage | Vss – 0.5 | – | Vdd + 0.5 | V |
|
|
VIO2 | DC Voltage Applied to | Vss – 0.5 | – | Vdd + 0.5 | V |
|
|
IMIO | Maximum Current into any Port Pin | – | +50 | mA |
|
| |
IMAIO | Maximum Current into any Port Pin | – | +50 | mA |
|
| |
| Configured as Analog Driver |
|
|
|
|
|
|
ESD | Electro Static Discharge Voltage | 2000 | – | – | V | Human Body Model ESD. |
|
LU | Latch Up Current | – | – | 200 | mA |
|
|
Operating Temperature |
|
|
|
|
|
| |
Table 7. Operating Temperature |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Parameter | Description | Min | Typ | Max | Unit | Notes |
|
TA | Ambient Temperature | 0 | – | +70 | °C |
|
|
TJ | Junction Temperature | 0 | – | +88 | °C | The temperature rise from |
|
|
|
|
|
|
| ambient to junction is |
|
|
|
|
|
|
| package specific. See |
|
|
|
|
|
|
| “Thermal Impedance” on |
|
|
|
|
|
|
| page 28. The user must limit |
|
|
|
|
|
|
| the power consumption to |
|
|
|
|
|
|
| comply with this |
|
|
|
|
|
|
| requirement. |
|
Document | Page 14 of 30 |
[+] Feedback