Bay Technical Associates DS72 manual Detailed Operation and Configuration, Main Screen

Page 13

DS72 Host Module

Detailed Operation and Configuration

Main Screen

DS72 - Ethernet & RS232 Host module for DS SERIES chassis

Once connected, you will see the menu screen as shown below. This shows the operation of the unit. Depending on which Network Host module you have, the below screens may vary. The screens below are show with the DS72 module. When prompted at the unit’s startup menu select “C” followed by a <cr>. This will take you to the Configuration menu.

Module: 2

 

 

Attention Character: ;

1

 

Device A

 

Device B

2

 

Device C

3

 

Device D

4

Status of outlets

DS-RPC

5

Configure

C

Module Setup

Status

S

Current Setup Configuration

Unit Reset

RU

Resets the DS-Unit, terminates internal,

 

 

external modem connections, allow 10

Logout

T

seconds for reset.

 

NOTE: Only the Admin user will see the Configuration, Unit Reset, and I/O Module Reset options. All users will see only the ports assigned to them, alone with ‘Exit’ and ‘Logout’.

NOTE: If you get the following message after selecting the ‘Configure’ option, the other port has the configuration option selected.

Configuration mode in use.

IMPORTANCE: Once you make a change to any of the Configuration options, you have to back out of the Configuration menu and will be asked to ‘Accept’ changes. If you type ‘y’ for yes and press <cr>, the changes take effect immediately for the serial port. For the Ethernet port you must do a Unit Reset to get the changes to take effect.

Accept changes ? (Y/N) :y

Changes accepted.

13

Image 13
Contents DS Series Manual DS72 Host Module EIA-232 Serial Connection DS72 Host Module Connection Description Power InstallationQuick Start DS72 Module Ethernet Controller ConfigurationMain Menu Serial Port SetupAccess Control Login SetupHeader Manage UsersNetwork Port Configuration Cabling Adapters SignalsRJ-45 Cables and Adapters Adapters Main Screen Detailed Operation and ConfigurationConfiguration Status Configuration MenuDS72 Host Module Serial Port ConfigurationWord Size Baud RateStop Bits Xon/Xoff ParityRTS/DTR Line Driver Inactivity State Disconnect Timeguard Serial Port Device NameConnection Override Connect Port ID EchoHeader Access ControlManage Users Change User’s PasswordAdd User Delete User Snmp ConfigurationSnmp Trap Host X IP Address Snmp EnableRead/Write Community String IP Address Subnet Mask Inactivity TimeoutGateway Carriage Return TranslationUnit ID DHCP/Telnet/BootPBreak Length Active Restore Upgrade FirmwareUnder Voltage Alarm Threshold Temperature Alarm ThresholdRPC Management Multiple Strip Current MonitorLow Current Alarm Threshold Over Voltage Alarm ThresholdEnvironmental Sensors Selection 1, the Host Module responds System StatusTroubleshooting Unit ResetNetwork Interface Logged UsersNo Access to Configuration Menu Password not WorkNo Menu Ethernet Port Network session locks upNot able to Ping unit No Outlets displayed for UserVerify DS chassis, Host module, and DS74 is functioning DS72 Host Module Cabling DS72 SetupExceptions BayTech Product WarrantyEmail support@baytech.net Technical SupportReturn Authorization Process