Bay Technical Associates DS72 manual Return Authorization Process

Page 38

DS72 Host Module

Return Authorization Process:

1.Contact BayTech to get a Return Authorization (RA) Number. IMPORTANT: BayTech will not accept any returns without an RA number.

2.Package the unit carefully in its original packaging or similar packaging. The warranty does not cover damage sustained during shipment. Enclose a letter with name, address, RA number, daytime phone number and description of the problem.

3.Mark the RA number clearly on the outside of the package.

NOTE: If the RA number is not on the outside of the box, the package will be returned back to the sender or will sit in Receiving until the customer calls in regarding status of RA.

4. Ship the unit by insured, prepaid carrier to the following address:

Bay Technical Associates 5239 A Avenue

Long Beach Industrial Park Long Beach, MS 39560 RA #: 140-xxxxx

5.Surround your unit with a minimum of two inches of insulation.

6.Be sure to seal the box securely with strapping or packing tape. We do not recommend masking tape or cellophane tape.

38

Image 38
Contents DS Series Manual DS72 Host Module EIA-232 Serial Connection DS72 Host Module Connection Description Installation PowerEthernet Controller Configuration Quick Start DS72 ModuleSerial Port Setup Main MenuHeader Login SetupAccess Control Manage UsersNetwork Port Configuration RJ-45 Cables and Adapters Adapters SignalsCabling Adapters Detailed Operation and Configuration Main ScreenConfiguration Menu Configuration StatusSerial Port Configuration DS72 Host ModuleStop Bits Baud RateWord Size RTS/DTR Line Driver Inactivity State ParityXon/Xoff Connection Override Serial Port Device NameDisconnect Timeguard Connect Port ID EchoAccess Control HeaderAdd User Change User’s PasswordManage Users Snmp Configuration Delete UserRead/Write Community String Snmp EnableSnmp Trap Host X IP Address IP Address Gateway Inactivity TimeoutSubnet Mask Carriage Return TranslationBreak Length DHCP/Telnet/BootPUnit ID Upgrade Firmware Active RestoreRPC Management Temperature Alarm ThresholdUnder Voltage Alarm Threshold Multiple Strip Current MonitorEnvironmental Sensors Over Voltage Alarm ThresholdLow Current Alarm Threshold Selection 1, the Host Module responds Status SystemNetwork Interface Unit ResetTroubleshooting Logged UsersNo Menu Ethernet Port Password not WorkNo Access to Configuration Menu Network session locks upVerify DS chassis, Host module, and DS74 is functioning No Outlets displayed for UserNot able to Ping unit DS72 Host Module DS72 Setup CablingBayTech Product Warranty ExceptionsTechnical Support Email support@baytech.netReturn Authorization Process