Bay Technical Associates DS72 manual Subnet Mask, Gateway, Inactivity Timeout

Page 24

DS72 Host Module

NOTE: There should be no active connections while configuring the Host Module. The unit should be reset upon completion of configuration.

Subnet Mask

The Subnet Mask is a bit mask that identifies the network portion of the IP address, allowing the Host Module to determine whether to send a packet directly to the client or to a gateway. The Subnet Mask consists of four bytes, each byte ranging from 0 to 255. This parameter must be programmed before the DS-Series can be accessed through the network.

Enter the Subnet Mask (Example: 255.255.255.0), followed by <cr>. The Host Module resumes the configuration menu. Default Subnet Mask is 0.0.0.0. If you fail to enter the Subnet Mask in dotted decimal form, the Host Module responds again:

Enter Subnet Mask in dotted decimal form :

The Host Module responds indefinitely with the same request until the Subnet Mask is entered in the correct form.

Gateway

The Gateway is the address of a router for connection to their networks. The Gateway address consists of four bytes, each byte ranging from 0 to 255. If your network uses gateways, this parameter must be programmed before the Host Module can be accessed through a network. Enter the Gateway address (Example: 200.4.5.50), followed by <cr>. Default Gateway address is 0.0.0.0. If you fail to enter the Gateway address in dotted decimal form, the Host Module responds again:

Enter Gateway address in dotted decimal form :

The Host Module responds indefinitely with the same request until the Gateway address is entered in the correct form.

Inactivity Timeout

When this option is enabled, the Host Module will automatically disconnect, if there is no activity, after the programmed amount of time. Default is 0 (disabled). The enabling input can be from 1 to 120 minutes.

Connection Inactivity Timeout is 0 minutes

Enter timeout, in minutes (<=120, 0 to disable) :

Enter 0 to disable or a number between 1 and 120 (inclusive) to set the timeout.

Carriage Return Translation

Press “Y” to enable the Host Module Telnet processor to strip line feeds or nulls Translation which follow carriage returns. Press “N” to allow the characters to pass through and press <cr> to leave this option unchanged. Default is “disabled”.

24

Image 24
Contents DS Series Manual DS72 Host Module EIA-232 Serial Connection DS72 Host Module Connection Description Installation PowerEthernet Controller Configuration Quick Start DS72 ModuleSerial Port Setup Main MenuLogin Setup Access ControlHeader Manage UsersNetwork Port Configuration Adapters Signals CablingRJ-45 Cables and Adapters Adapters Detailed Operation and Configuration Main ScreenConfiguration Menu Configuration StatusSerial Port Configuration DS72 Host ModuleBaud Rate Word SizeStop Bits Parity Xon/XoffRTS/DTR Line Driver Inactivity State Serial Port Device Name Disconnect TimeguardConnection Override Connect Port ID EchoAccess Control HeaderChange User’s Password Manage UsersAdd User Snmp Configuration Delete UserSnmp Enable Snmp Trap Host X IP AddressRead/Write Community String IP Address Inactivity Timeout Subnet MaskGateway Carriage Return TranslationDHCP/Telnet/BootP Unit IDBreak Length Upgrade Firmware Active RestoreTemperature Alarm Threshold Under Voltage Alarm ThresholdRPC Management Multiple Strip Current MonitorOver Voltage Alarm Threshold Low Current Alarm ThresholdEnvironmental Sensors Selection 1, the Host Module responds Status SystemUnit Reset TroubleshootingNetwork Interface Logged UsersPassword not Work No Access to Configuration MenuNo Menu Ethernet Port Network session locks upNo Outlets displayed for User Not able to Ping unitVerify DS chassis, Host module, and DS74 is functioning DS72 Host Module DS72 Setup CablingBayTech Product Warranty ExceptionsTechnical Support Email support@baytech.netReturn Authorization Process