Bay Technical Associates manual Quick Start DS72 Module, Ethernet Controller Configuration

Page 7

DS72 Host Module

to the power source. Do not attempt to modify any portion or component of a DS72 module unless specifically directed by BayTech Technical Support. BayTech must perform any internal changes.

CAUTION: High-voltage surges and spikes can damage this equipment. To protect from such power surges and spikes, this unit must have a good earth ground. A grounding screw connection is located near the power switch on the back of the unit.

CAUTION: Before removing or replacing any modules, turn off main power switch located on the DS-Series Base Unit. Communication to the DS-Series Data Switch will be disrupted while power is off.

QUICK START: DS72 Module

by Bay Technical Associates

For those Administrators who have requested the bare minimum for this type of equipment, follow these steps exactly. If this is a new unit shipped directly from Baytech, follow the steps. If this is a previously own unit, perform a factory reset to clear out any users and passwords still in the unit.

Ethernet Controller Configuration:

Before continuing your System Administrator needs to tell you to use DHCP or BOOTP or give you an IP Address, Subnet Address, and Gateway Address.

1.Connect the 9FRJ45PC-4 or 9FRJ45PC-1 adapter to your PC.

2.Connect the supplied rollover flat cable RJ08X007 to the adapter and to the EIA232 serial port on the Baytech DS62 Module.

3.Use terminal emulation software to access the unit, (i.e. Microsoft Hyper-terminal). Set the PC serial port configuration to the following: 9600 bps, 8 data bits, 1stop bit and no parity.

4.If you get only a blinking cursor Press ‘Enter’. If still only a blinking cursor, Type 5 semi-colons (;),The Attention Character will not echo on the screen. There is a one second delay before the menu is displayed. You should see a menu similar to (Figure 1).

5.Select ‘C’ for the configuration menu.

6.Select the DS72 module. You should see a menu similar to (Figure 2).

7.Select the number for ‘Login Setup’ option. You should see a menu similar to (Figure 3).

8.Select the number for ‘Manage Users’ option. You should see a menu similar to (Figure 4).

9.NOTE: The ‘admin’ user can not be deleted.

10.Select ‘A’ to add user. Type the name and password at the prompts.

11.Press ‘Enter’ until get to the ‘Login Setup Menu’ (Figure 3).

12.Select option ‘Access Control’ to enable or disable the Tenet and Serial Login Prompt.

13.Press ‘Enter’ until you get the Configuration menu (Figure 2).

14.Select ‘Network Port Configuration’ option. You should see a menu similar to (Figure 5).

15.If your System Administrator requires you to use DHCP, then select ‘DHCP Enable/Disable’ and type ‘Y’ to enable DHCP. If you wish to assign a static IP address to this unit, Disable the DHCP and go to step 18.

16.Press ‘Enter’ until you are asked to ‘Accept Changes’. Type ‘Y’ to accept changes or ‘N’ to decline changes.

17.After Accepting or Declining Changes Pres ‘Enter ‘ until you get the Network Access Menu (Figure 1).

18.Select ‘Unit reset’ to update the external connections. Once the reset is completed (1 minute) connect the Baytech device to your network using an Ethernet cable.

19.If you disabled the DHCP in step 15, you should see a menu similar to (Figure 5).

20.Select the ‘IP Address’ option and type the assigned IP address and press ‘Enter’.

21.Select the ‘Subnet Mask’ option and type the assigned subnet mask address and press ‘Enter’.

7

Image 7
Contents DS Series Manual DS72 Host Module EIA-232 Serial Connection DS72 Host Module Connection Description Power InstallationQuick Start DS72 Module Ethernet Controller ConfigurationMain Menu Serial Port SetupManage Users Login SetupAccess Control HeaderNetwork Port Configuration Cabling Adapters SignalsRJ-45 Cables and Adapters Adapters Main Screen Detailed Operation and ConfigurationConfiguration Status Configuration MenuDS72 Host Module Serial Port ConfigurationWord Size Baud RateStop Bits Xon/Xoff ParityRTS/DTR Line Driver Inactivity State Connect Port ID Echo Serial Port Device NameDisconnect Timeguard Connection OverrideHeader Access ControlManage Users Change User’s PasswordAdd User Delete User Snmp ConfigurationSnmp Trap Host X IP Address Snmp EnableRead/Write Community String IP Address Carriage Return Translation Inactivity TimeoutSubnet Mask GatewayUnit ID DHCP/Telnet/BootPBreak Length Active Restore Upgrade FirmwareMultiple Strip Current Monitor Temperature Alarm ThresholdUnder Voltage Alarm Threshold RPC ManagementLow Current Alarm Threshold Over Voltage Alarm ThresholdEnvironmental Sensors Selection 1, the Host Module responds System StatusLogged Users Unit ResetTroubleshooting Network InterfaceNetwork session locks up Password not WorkNo Access to Configuration Menu No Menu Ethernet PortNot able to Ping unit No Outlets displayed for UserVerify DS chassis, Host module, and DS74 is functioning DS72 Host Module Cabling DS72 SetupExceptions BayTech Product WarrantyEmail support@baytech.net Technical SupportReturn Authorization Process