DS72 Host Module

1 For 1

2For 1-1/2

3For 2

Parity

Parity is a simple form of error checking used in serial communication. For even and odd parity, the serial port will set the parity bit (the last bit after the data bits) to a value to ensure that the transmission has an even or odd number of logic high bits. For example, if the data was 011, then for even parity, the parity bit would be 0 to keep the number of logic high bits even. If the parity was odd, then the parity bit would be 1, resulting in 3 logic high bits. This allows the receiving device to know the state of a bit so as to enable the device to determine if noise is corrupting the data or if the transmitting and receiving devices' clocks are out of sync.

With no parity selected (or defaulted), it's assumed that there are other forms of checking that will detect any errors in transmission. No parity also usually means that the parity bit can be used for data, speeding up transmission. In modem-to-modem communication, the type of parity is coordinated by the sending and receiving modems before the transmission takes place.

Select “Parity” the DS displays the following: Default is None.

1 For None

2 For Even

3 For Odd

Xon/Xoff

For a simple communication between modems three connected lines are needed: TX, Rx, and Ground. For the data to be transmitted, both sides have to be clocking the data at the same baud rate. While this method is sufficient for most applications, it is limited in being able to respond to problems such as the receiver getting overloaded. This is where serial handshaking can help. Xon/Xoff is software data flow communications protocol for controlling the flow of data between Baytech and other devices. Baytech units will send an XOFF character when it can't take any more data and when it can once again take more data, will send an XON character to the transmitter.

Select “Xon/Xoff” the DS displays the following, Default is Off:

Output Flow Control (Xmit) - Xon/Xoff is ( Off )

Stop/Restart Output Upon Receiving of Xoff/Xon ? (Y/N) :

Output Flow Control (Recv) - Xon/Xoff is ( Off )

Xoff/Xon sent based on Buffer - Full/Empty Condition ? (Y/N) :

RTS/DTR Line Driver Inactivity State

RTS (Request to Send)/ DTR (Data Terminal Ready) is normally used in conjunction with an external modem. With no modem the RTS and DTS default state is Low.

Select “RTS Driver State” the DS displays the following:

RTS Line Driver Inactive State is: Low

High ? (Y/N, CR for no change):

Select “DTR Driver State” the DS displays the following:

17

Image 17
Contents DS Series Manual DS72 Host Module EIA-232 Serial Connection DS72 Host Module Connection Description Power InstallationQuick Start DS72 Module Ethernet Controller ConfigurationMain Menu Serial Port SetupAccess Control Login SetupHeader Manage UsersNetwork Port Configuration RJ-45 Cables and Adapters Adapters SignalsCabling Adapters Main Screen Detailed Operation and ConfigurationConfiguration Status Configuration MenuDS72 Host Module Serial Port ConfigurationStop Bits Baud RateWord Size RTS/DTR Line Driver Inactivity State ParityXon/Xoff Disconnect Timeguard Serial Port Device NameConnection Override Connect Port ID EchoHeader Access ControlAdd User Change User’s PasswordManage Users Delete User Snmp ConfigurationRead/Write Community String Snmp EnableSnmp Trap Host X IP Address IP Address Subnet Mask Inactivity TimeoutGateway Carriage Return TranslationBreak Length DHCP/Telnet/BootPUnit ID Active Restore Upgrade FirmwareUnder Voltage Alarm Threshold Temperature Alarm ThresholdRPC Management Multiple Strip Current MonitorEnvironmental Sensors Over Voltage Alarm ThresholdLow Current Alarm Threshold Selection 1, the Host Module responds System StatusTroubleshooting Unit ResetNetwork Interface Logged UsersNo Access to Configuration Menu Password not WorkNo Menu Ethernet Port Network session locks upVerify DS chassis, Host module, and DS74 is functioning No Outlets displayed for UserNot able to Ping unit DS72 Host Module Cabling DS72 SetupExceptions BayTech Product WarrantyEmail support@baytech.net Technical SupportReturn Authorization Process