Bay Technical Associates DS72 manual Unit ID, Break Length, DHCP/Telnet/BootP

Page 25

DS72 Host Module

Carriage Return Translation is.... Enabled

Enable ? (Y/N), CR for no change) :

Break Length

Users may configure the Host Module for a break length of 1 - 1000 milliseconds. When a user, running a Telnet session with the Host and connected to a serial port on a DS74, sends a Telnet break command (0xF3) to the Host Module, the serial port will send a break signal of the programmed duration. Default is 350 milliseconds.

Break Length is (msec)

350

Enter break length, in milliseconds (<=10000, 0 to disable) :

DHCP/Telnet/BootP

Dynamic Host Configuration Protocol (DHCP) is a communications protocol that lets network administrators manage centrally and automate the assignment of Internet Protocol (IP) addresses in an organization's network. Default setting is disabled.

DHCP is...........................Disabled

Enable ? (Y/N), CR for no change) :

Telnet is a user command and an underlying TCP/IP protocol for accessing remote devices. On the Web, HTTP and FTP protocols allow you to request specific files from remote computers, but not to actually be logged on as a user of that computer. Default setting is enabled.

NOTE: Changing this setting will logout all SSH and Telnet sessions

Telnet is.........................Enabled

Enable ? (Y/N), CR for no change) :

Bootstrap Protocol (BOOTP) is a protocol that enables the unit to obtain an IP Address from a BOOTP server. Default setting is enabled.

BOOTP is.........................Enabled

Enable ? (Y/N), CR for no change) :

Unit ID

This option allows the admin users to change the Host Module’s name.

Unit ID is: DS72

Enter Unit ID (64 chars max). : DS72 Desk Test

25

Image 25
Contents DS Series Manual DS72 Host Module EIA-232 Serial Connection DS72 Host Module Connection Description Power InstallationQuick Start DS72 Module Ethernet Controller ConfigurationMain Menu Serial Port SetupAccess Control Login SetupHeader Manage UsersNetwork Port Configuration Cabling Adapters SignalsRJ-45 Cables and Adapters Adapters Main Screen Detailed Operation and ConfigurationConfiguration Status Configuration MenuDS72 Host Module Serial Port ConfigurationWord Size Baud RateStop Bits Xon/Xoff ParityRTS/DTR Line Driver Inactivity State Disconnect Timeguard Serial Port Device NameConnection Override Connect Port ID EchoHeader Access ControlManage Users Change User’s PasswordAdd User Delete User Snmp ConfigurationSnmp Trap Host X IP Address Snmp EnableRead/Write Community String IP Address Subnet Mask Inactivity TimeoutGateway Carriage Return TranslationUnit ID DHCP/Telnet/BootPBreak Length Active Restore Upgrade FirmwareUnder Voltage Alarm Threshold Temperature Alarm ThresholdRPC Management Multiple Strip Current MonitorLow Current Alarm Threshold Over Voltage Alarm ThresholdEnvironmental Sensors Selection 1, the Host Module responds System StatusTroubleshooting Unit ResetNetwork Interface Logged UsersNo Access to Configuration Menu Password not WorkNo Menu Ethernet Port Network session locks upNot able to Ping unit No Outlets displayed for UserVerify DS chassis, Host module, and DS74 is functioning DS72 Host Module Cabling DS72 SetupExceptions BayTech Product WarrantyEmail support@baytech.net Technical SupportReturn Authorization Process