Bay Technical Associates DS72 No Menu Ethernet Port, Password not Work, Network session locks up

Page 32

DS72 Host Module

d.Type 5(;), the Attention Character will not echo to the screen, if it does than it may have been changed to a character other than the semi-colon.

2.No Menu Ethernet Port:

a.Note what the CX LED is doing, refer to Appendix C.

b.Verify the Ethernet port is connected to your network via an Ethernet cable. The LINK LED is lit for a valid connection.

c.Type 5(;) semi-colon, the Attention Character will not echo to the screen, if it does print or Unknown character than type each character on the keyboard 5-times until you discover the Attention character, else reset unit configuration.

3.Password not Work:

a.Password is case sensitive, check for Caps Lock.

b.Have the admin user delete the user and add back

i.Refer to DS Configuration/User Management ‘Delete a User’ and ‘Add a User’ section.

ii.Refer to Network Access Configuration/Login Setup/Manage Users

4.Network session locks up:

a.More than 4 sessions are open, close one session.

5.No Access to Configuration Menu:

a.Only one user at a time can have access. Have the other user back out of the configuration

32

Image 32
Contents DS Series Manual DS72 Host Module EIA-232 Serial Connection DS72 Host Module Connection Description Installation PowerEthernet Controller Configuration Quick Start DS72 ModuleSerial Port Setup Main MenuLogin Setup Access ControlHeader Manage UsersNetwork Port Configuration RJ-45 Cables and Adapters Adapters SignalsCabling Adapters Detailed Operation and Configuration Main ScreenConfiguration Menu Configuration StatusSerial Port Configuration DS72 Host ModuleStop Bits Baud RateWord Size RTS/DTR Line Driver Inactivity State ParityXon/Xoff Serial Port Device Name Disconnect TimeguardConnection Override Connect Port ID EchoAccess Control HeaderAdd User Change User’s PasswordManage Users Snmp Configuration Delete UserRead/Write Community String Snmp EnableSnmp Trap Host X IP Address IP Address Inactivity Timeout Subnet MaskGateway Carriage Return TranslationBreak Length DHCP/Telnet/BootPUnit ID Upgrade Firmware Active RestoreTemperature Alarm Threshold Under Voltage Alarm ThresholdRPC Management Multiple Strip Current MonitorEnvironmental Sensors Over Voltage Alarm ThresholdLow Current Alarm Threshold Selection 1, the Host Module responds Status SystemUnit Reset TroubleshootingNetwork Interface Logged UsersPassword not Work No Access to Configuration MenuNo Menu Ethernet Port Network session locks upVerify DS chassis, Host module, and DS74 is functioning No Outlets displayed for UserNot able to Ping unit DS72 Host Module DS72 Setup CablingBayTech Product Warranty ExceptionsTechnical Support Email support@baytech.netReturn Authorization Process