Bay Technical Associates DS72 Serial Port Device Name, Disconnect Timeguard, Connection Override

Page 18

DS72 Host Module

DTR Line Driver Inactive State is: Low

High ? (Y/N, CR for no change):

Serial Port Device Name

Select a port and type the new name:

Enter Port Device Name (Max. 16 characters): or press ENTER for no change .....:

Attention Character

Pressing the Attention Character 5 consecutive times will access the network main menu. The Default is a semi-colon (;). Select this option to change the attention character. The DS displays the following:

Attention Character is

;

Enter Attention Character :

 

NOTE: If you change the attention character and forget which letter or symbol you selected, the attention character will not echo if you are typing the correct character. You can type each character/symbol on the keyboard to find it, or reset the module to factory default to get the semi-colon back.

Disconnect Timeguard

This feature provides reliable binary data transmission by providing a one-second “Timeguard” after the DS-Series receives the attention character. If more data is received within the delay period, the DS series treats the character as data, not an attention character; thereby preventing unwanted port disconnection. The Default setting is Disabled.

Disconnect Time Guard

is

..........Disabled

Enable ? (Y/N, CR for

no

change) :

Connection Override

This feature allows the admin user to override another user’s connection and force priority over the other users. Default setting is enabled.

Connection override is

Enabled

Enable ? (Y/N, CR for no change) :

 

Connect Port ID Echo

When a user logs into the DS unit the port is identified in the following example:

18

Image 18
Contents DS Series Manual DS72 Host Module EIA-232 Serial Connection DS72 Host Module Connection Description Installation PowerEthernet Controller Configuration Quick Start DS72 ModuleSerial Port Setup Main MenuHeader Login SetupAccess Control Manage UsersNetwork Port Configuration Adapters Signals CablingRJ-45 Cables and Adapters Adapters Detailed Operation and Configuration Main ScreenConfiguration Menu Configuration Status Serial Port Configuration DS72 Host ModuleBaud Rate Word SizeStop Bits Parity Xon/XoffRTS/DTR Line Driver Inactivity State Connection Override Serial Port Device NameDisconnect Timeguard Connect Port ID EchoAccess Control HeaderChange User’s Password Manage UsersAdd User Snmp Configuration Delete UserSnmp Enable Snmp Trap Host X IP AddressRead/Write Community String IP Address Gateway Inactivity TimeoutSubnet Mask Carriage Return TranslationDHCP/Telnet/BootP Unit IDBreak Length Upgrade Firmware Active RestoreRPC Management Temperature Alarm ThresholdUnder Voltage Alarm Threshold Multiple Strip Current MonitorOver Voltage Alarm Threshold Low Current Alarm ThresholdEnvironmental Sensors Selection 1, the Host Module responds Status SystemNetwork Interface Unit ResetTroubleshooting Logged UsersNo Menu Ethernet Port Password not WorkNo Access to Configuration Menu Network session locks upNo Outlets displayed for User Not able to Ping unitVerify DS chassis, Host module, and DS74 is functioning DS72 Host Module DS72 Setup CablingBayTech Product Warranty ExceptionsTechnical Support Email support@baytech.netReturn Authorization Process