Bay Technical Associates DS72 manual Over Voltage Alarm Threshold, Low Current Alarm Threshold

Page 28

DS72 Host Module

Sel

M/P

Identifier

Lo V Lvl

Sel

M/P

Identifier

Lo V Lvl

1

2/1

rpc14

900

2

5/1

DS-RPC

900

Enter Request :1

 

 

 

 

 

Type #1 for the selection, press <cr> and the Host Module responds:

Enter voltage threshold value in tenths of a volt:

Over Voltage Alarm Threshold

Select 4), Over Voltage Alarm Threshold and the Host Module responds:

Sel

M/P

Identifier

Hi V Lvl

Sel

M/P

Identifier

Hi V Lvl

1

2/1

rpc14

1300

2

5/1

DS-RPC

1300

Enter Request :1

 

 

 

 

 

Type #1 for the selection, press <cr> and the Host Module responds:

Enter voltage threshold value in tenths of a volt:

Low Current Alarm Threshold

Select 5), Low Current Alarm Threshold and the Host Module responds:

Sel

M/P

Identifier

Low Curr

Sel

M/P

Identifier

Low Curr

1

2/1

rpc14

0

2

5/1

DS-RPC

0

Enter Request :1

 

 

 

 

 

Type #1 for the selection, press <cr> and the Host Module responds:

Enter low current threshold value in tenths of an amp:

Environmental Sensors

Select 6), Environmental Sensors with no environmental probes are attached the Host Module responds:

None of the installed devices support this option (no temperature probes installed).

Strike ENTER to continue

If you have environmental probes attached the Host Module responds:

Environmental Sensor Configuration Menu

Sel M/P Identifier

12/1 RPC3ADE

2All Sensors Enter Request :1

28

Image 28
Contents DS Series Manual DS72 Host Module EIA-232 Serial Connection DS72 Host Module Connection Description Installation PowerEthernet Controller Configuration Quick Start DS72 ModuleSerial Port Setup Main MenuLogin Setup Access ControlHeader Manage UsersNetwork Port Configuration Cabling Adapters SignalsRJ-45 Cables and Adapters Adapters Detailed Operation and Configuration Main ScreenConfiguration Menu Configuration StatusSerial Port Configuration DS72 Host ModuleWord Size Baud RateStop Bits Xon/Xoff ParityRTS/DTR Line Driver Inactivity State Serial Port Device Name Disconnect TimeguardConnection Override Connect Port ID EchoAccess Control HeaderManage Users Change User’s PasswordAdd User Snmp Configuration Delete UserSnmp Trap Host X IP Address Snmp EnableRead/Write Community String IP Address Inactivity Timeout Subnet MaskGateway Carriage Return Translation Unit ID DHCP/Telnet/BootP Break Length Upgrade Firmware Active RestoreTemperature Alarm Threshold Under Voltage Alarm ThresholdRPC Management Multiple Strip Current MonitorLow Current Alarm Threshold Over Voltage Alarm ThresholdEnvironmental Sensors Selection 1, the Host Module responds Status SystemUnit Reset TroubleshootingNetwork Interface Logged UsersPassword not Work No Access to Configuration MenuNo Menu Ethernet Port Network session locks upNot able to Ping unit No Outlets displayed for UserVerify DS chassis, Host module, and DS74 is functioning DS72 Host Module DS72 Setup CablingBayTech Product Warranty ExceptionsTechnical Support Email support@baytech.netReturn Authorization Process
Related manuals
Manual 35 pages 54.1 Kb