INSTALLATION
INSTALLATION
Unpacking
Delivery Inspection
After removing the carton, carefully inspect the power management system components for any damage that may have occurred during shipment.
IMPORTANT: If loss or damage is noted at time of delivery, have the person(s) making delivery note all damage on the freight bill and affix his signature under the consignor's memo of loss or damage. If loss or damage is noted after delivery, contact the carrier for claim procedures. Missing or damaged parts are not warranted.
Shipment Contents
•Power Management System
•Installation and Operator’s Manual
•Wire Connectors (4)
•1/4” Double Male, Single Female Lugs (2)
Mounting Guidelines
The power management system is enclosed in a NEMA Type 3R enclosure suitable for indoor/outdoor use. Guidelines for mounting the power management system include:
•Install power management system on a firm, sturdy supporting structure.
•The power management system must be installed with minimum NEMA 3R hardware for conduit connections.
•Level and plumb the enclosure.This can be done by placing washers between the power management system enclosure and the mounting surface.
•NEVER install the power management system where any corrosive substance might drip onto the enclosure.
•Protect the power management system at all times against excessive moisture, dust, dirt, lint, construction grit and corrosive vapors.
A typical installation of the power management system is depicted in Figure 1. It is best if it is mounted near the main breaker panel, either inside or outside. Discuss layout suggestions/changes with the owner before beginning the system installation process.
Figure 1 — A Typical Power Management System Mounting
| Watt - |
| Hourmeter |
| Service Disconnect |
Contactor |
|
Main | Transfer |
Breaker | Switch |
Panel | Generator |
Hot |
|
Water | Power |
Heater | Management |
| System |
| Air |
| Conditioner |
Branch Circuits |
|
| Disconnect Switch |