Maxon Telecom MM-6280IND manual TA BLE of Contents

Page 5

TA BLE OF CONTENTS

Extended AT Commands Manual

1

RF EXPOSURE COMPLIANCE

2

CAUTION

 

2

REVISION HISTORY

3

CONTACT INFORMATION

4

TABLE OF CONTENTS

5

1.

OVERVIEW

......................................................................................................................

9

1.1.

 

General Description

9

1.2.

 

Terms

 

10

2.

AT INTERFACE DESCRIPTION

12

2.1.

 

Basic Integration

12

2.2.

 

Serial Interface

12

2.2.1.

Pin out

 

12

2.3.

 

Command Format

13

2.4.

 

Message Naming Convention

13

3.

BASIC INTERFACE CONFIGURATION

14

3.1.

 

Baud Rate Set-up

14

3.2.

 

Serial Interface

14

3.3.

 

USB Interface

14

3.4.

 

IO Functions

15

3.5.

 

AT Notification Options

15

4.

SIGNAL INFORMATION

17

4.1.

 

MT SMS

 

17

4.2.

 

MT DATA

 

17

5.

INTERFACE ENVIRONMENT

18

5.1.

MT2 Basic Operational State

18

 

5.1.1.1.

Boot alert

18

 

Note:

18

 

 

 

5.1.1.2.

Lock order

18

 

5.1.1.3. SMS TE2 emergency MO registration alert (AT$$EMMOREG)

18

 

5.1.1.4. TE2 active command (AT$$TE2ALIVE)

19

 

5.1.1.5.

Power Reset (AT$$RESET)

19

 

Note:

20

 

 

 

5.1.1.6.

Current time (AT$$TIME)

20

 

5.1.1.7.

Software version (AT$$SWVER)

20

5.2.

 

Power Conservation Commands

20

 

5.2.1.1. Sleep mode control (AT$$SLEEP_ENABLE)

20

 

5.2.1.2.

LED control (AT$$EXT_LED)

22

 

5.2.1.3. RS232C Transceiver power-down control (AT$$RS232_PWRDOWN)

22

5.3. Low Battery Voltage Notification

22

 

5.3.1.1. SMS low battery voltage set point (AT$$LOWBATT_VTG)

23

 

5.3.1.2. Low battery notification (AT$$LOWBATT)

23

Extended AT Commands Manual

Page 5 of 70

2009-06-25

Image 5
Contents Extended AT Commands Manual Potentially Unsafe Areas RF Exposure ComplianceRevision History Contact Information TA BLE of Contents 1.3 2.1 Carrier Command Options General Description OverviewTerms RCE PstnSMS TE2Basic Integration AT Inte Rface DescriptionSerial Interface Pin outMessage Naming Convention Command FormatBaud Rate Set-up Basic Interface ConfigurationUSB Interface TE2 MT2AT Notification Options IO FunctionsTE2 MT2 $$IOFUNCTION? TE2 MT2 $$NOTIFCNT?$$NOTIFCNT 1 0 Success Failure Set command Command$$NOTIFCNT=value MT Data Signal InformationMT SMS Interface Environment Boot alertMT2 Basic Operational State Lock orderPower Reset AT$$RESET 1.4. TE2 active command AT$$TE2ALIVESleep mode control AT$$SLEEPENABLE Power Conservation CommandsCurrent time AT$$TIME Software version AT$$SWVERExtended AT Commands Manual 2009-06-25 1.3. RS232C Transceiver power-down control AT$$RS232PWRDOWN Low Battery Voltage NotificationLED control AT$$EXTLED TE2 MT2 $$EXTLED?TE2 MT2 $$LOWBATTVTG? SMS low battery voltage set point AT$$LOWBATTVTGLow battery notification AT$$LOWBATT Ringer volume control AT$$RINGLVL Receiving notification mode option AT$$RCVMODEVisual/Audible Call Alert Options Ringer melody selection AT$$RINGIDXRoaming indicator information AT$$ROAMIND Network Relational SettingsAntenna Signal Level report schedule AT$$ANTSET Antenna Signal Level AT$$ANTLVLReading MT2 state AT$$CURRSTATE Modem scheduled Information AT$$PingRssi inquiry AT$$RSSI TE2 MT2 $$LOCATION? RF information AT$$RFINFOLocation information AT$$LOCATION Ring test AT$$DIAGRING Diagnostic CommandsLED test AT$$DIAGLED Rssi LED response AT$$RSSILEVELCRT Led DescriptionPKT TX/DTRData Calls Data Call SET UPCall released or failed Uses DTR pin MO data callSelect Message Service +CSMS General Configuration Commands+CSMS action command syntax Preferred Message Storage +CPMSMessage Format +CMGF Message Service Failure Result Code +CMS ErrorInformative Examples Message Configuration CommandsService Centre Address +CSCA Show Text Mode Parameters +CSDH Set Text Mode Parameters +CSMPNew Message Indications to TE +CNMI Message Receiving and Reading commandsAlpha,scts,tooa,fo,pid,dcs,sca,tosca List Messages +CMGL Read Message +CMGR If text mode +CMGF=1, command successful and SMS-DELIVERIf text mode +CMGF=1, command successful and SMS-SUBMIT Report New Message Acknowledgement to ME/TA +CNMASend Message +CMGS Message Sending and Writing CommandsSend Message from Storage +CMSS If text mode +CMGF=1 If text mode +CMGF=1 and sendingSuccessful If sending failsWrite Message to Memory +CMGW Send Message Telstra SMS MO AT+MMCDelete Message +CMGD Send Command +CMGCAT+CNMI? More Messages to Send +CMMSAT+CMSS=7 SMS Mail Notification Option SMSOPT=AB SMS Send and Receive OptionsSMS Format send and receiveAT$$SMSOPT TE2 MT2 $$SMSOPT?SMS Mail Notification Option SMSOPT=2 SMS Mail Notification Option SMSOPT=1SMS Mail Notification Option SMSOPT=3 Illustrative exampleSMS Notifications Auto delete Messages in ME MemoryAuto Delete Messages in ME memory$$AUTODLTSMS SMS Notification $$SMSNOTIFAuto Voltage Alert SMS Site Name AT$$SITENAME SMS Auto Voltage AlertSMS $$LOWBATT 1 set point AT$$LOWBATTVTG TE2 MT2 $$SITENAME?SMS Remote Report Request Site Name AT$$REMOTECTRL SMS Remote Report RequestsSMS $$LOWBATT 1 set recipient number AT$$AUTOSMS 10.1.2.4 Rssi request Read ALL requestVbatt request Debug Screen request Location requestSwver request 73 Read command Enter directory number of specific MT2 Remote ResetEnter message maxon.reset not case sensitive Value Modem will resetNVM vs . US ER PR Ofile Storage Command User Remarks ProfileTE2 MT2 OK Error TIA/EIA/IS 707A AT Command SETUser modified profiles & NVM changes User Profile store AT&WnBasic AT Parameters Basic AT CommandsSTU IIIBasic S registers Basic action command set Extended AT Commands Manual 2009-06-25 Basic result codes Extended AT Command SetsExtended AT configuration command set +GMI +GCAP+GMM +GMR+ICF 8Data 1Stop DefaultSpace Default +IFC Circuit 133 Ready for Receiving DefaultCircuit 106 Clear to Send/Ready for Sending Default +IPR 115200bps. DefaultTE2 MT2 $$NOTIDS 13.1.1. RM3 AT$$NOTIDSTE2 MT2 $$NOTIDS? Cellular AT parameter commands Cellular Extended AT Command SET+CDS +CBC?+CGMI Cellular identification AT command extensions+CGMM +CGMRCellular result codes for Asynchronous data services DM Comman D Diagnostic Mode TE2 MT2 $$DBGSCRN Carrier Command OptionsDebug screen AT$$DBGSCRN
Related manuals
Manual 60 pages 51.94 Kb

MM-6280IND specifications

The Maxon Telecom MM-6280IND is a robust and versatile two-way radio designed to meet the demanding needs of professionals in various fields, including security, construction, and transportation. This model stands out for its combination of advanced features, reliable performance, and user-friendly interface, making it a preferred choice for organizations requiring efficient communication solutions.

One of the key features of the MM-6280IND is its long battery life. Equipped with a high-capacity lithium-ion battery, this radio can provide extended operational time, ensuring that users can stay connected throughout their shifts without frequent recharging interruptions. Additionally, the radio supports multiple battery-saving modes, allowing users to optimize power consumption according to their needs.

The MM-6280IND operates on multiple frequency bands, ensuring compatibility across various communication networks. It supports both analog and digital communication modes, making it adaptable to different environments and user preferences. This dual-mode capability enhances interoperability, allowing seamless communication with other radios, regardless of their technology.

In terms of audio quality, the MM-6280IND features advanced noise-cancellation technology. This ensures clear audio transmission even in noisy environments, such as construction sites or crowded events. Furthermore, the radio is equipped with a built-in speaker and microphone that deliver crisp and loud audio, allowing users to communicate effectively without straining their ears.

Durability is another hallmark of the MM-6280IND. The device is designed to withstand harsh conditions, featuring an IP65 rating for water and dust resistance. This makes it suitable for outdoor use, ensuring that it can function reliably, even in adverse weather conditions. The rugged construction of the radio also protects it from physical impacts, reducing the risk of damage from drops or bumps.

User-friendly functionality is prioritized in the MM-6280IND, with an intuitive keypad and a clear LCD display that make navigation straightforward. It also includes programmable buttons that allow users to customize settings and features according to their specific operational requirements.

Overall, the Maxon Telecom MM-6280IND is a high-performance two-way radio that combines longevity, durability, and adaptability. Its advanced communication technologies and user-focused design make it an excellent tool for professionals seeking efficient and reliable communication solutions in various industries. Whether used for coordinating team efforts or enhancing safety and security, the MM-6280IND is a valuable asset for any organization.