Maxon Telecom MM-6280IND manual Basic AT Commands, Basic AT Parameters, Stu, Iii

Page 56

12.2. Basic AT Commands

The following table specifies the basic AT parameters to be supported for the data service. Exceptions to EIA/TIA-602 are indicated by square brackets. Default settings are shown in bold.

12.2.1. Basic AT Parameters

Table 12.78 Basic AT parameters

 

Parameter

 

 

Description

 

Packet

STU-

 

 

 

 

Data

 

III

 

 

 

 

 

 

 

 

E0

 

 

Do not echo command set in command state or online

O

 

N/A

 

 

 

 

command state.

 

 

 

 

 

E1

 

 

Echo command set in command state or online command

O

 

N/A

 

 

 

 

state.

 

 

 

 

 

L0

 

Low speaker volume.

 

N/A

 

N/A

 

L1

 

Low speaker volume.

 

N/A

 

N/A

 

L2

 

 

Med speaker volume.

 

N/A

 

N/A

 

L3

 

 

High speaker volume.

 

N/A

 

N/A

 

M0

 

Speaker off.

 

N/A

 

N/A

 

M1

 

 

Speaker on until carrier reported (support of this feature is

N/A

 

N/A

 

 

 

 

optional).

 

 

 

 

 

Q0

 

Return result codes.

 

R

 

R

 

Q1

 

 

Do not return result codes.

R

 

N/A

 

V0

 

Display result codes as numbers.

R

 

R

 

V1

 

Display result codes as words.

R

 

R

 

X1

 

 

Enable additional result code CONNECT <rate>. Disable dial

N/A

 

N/A

 

 

 

 

tone and busy detection.1

 

 

 

 

 

X2

 

 

Enable additional result codes CONNECT <rate> and NO

N/A

 

N/A

 

 

 

DIALTONE. Disable busy detection. Enable dial tone

 

 

 

 

 

detection.1

 

 

 

 

 

X3

 

 

Enable additional result codes CONNECT <rate> and BUSY.

N/A

 

N/A

 

 

 

 

Enable busy detection. Disable dial tone detection.1

 

 

 

 

X4

 

 

Enable additional result codes CONNECT <rate>, BUSY

N/A

 

N/A

 

 

 

 

and NO DIALTONE. Enable busy and dial tone detection.1

 

 

 

 

 

 

 

Reset to default user configuration.

 

 

 

 

Z0

 

 

Note: ATZ with firmware R2.1.3 clears the +CSCA

R

 

N/A

 

 

 

 

settings. You have to enter the +CSCA values again to be

 

 

 

 

 

 

 

able to send SMS messages.

 

 

 

 

&C0

 

 

Circuit 109 (CF) always ON.

R

 

N/A

 

Extended AT Commands Manual

Page 56 of 70

 

2009-06-25

Image 56
Contents Extended AT Commands Manual RF Exposure Compliance Potentially Unsafe AreasRevision History Contact Information TA BLE of Contents 1.3 2.1 Carrier Command Options Overview General DescriptionTerms Pstn RCESMS TE2AT Inte Rface Description Basic IntegrationSerial Interface Pin outCommand Format Message Naming ConventionBasic Interface Configuration Baud Rate Set-upUSB Interface TE2 MT2IO Functions AT Notification OptionsTE2 MT2 $$IOFUNCTION? TE2 MT2 $$NOTIFCNT?$$NOTIFCNT 1 0 Success Failure Set command Command$$NOTIFCNT=value MT Data Signal InformationMT SMS Boot alert Interface EnvironmentMT2 Basic Operational State Lock order1.4. TE2 active command AT$$TE2ALIVE Power Reset AT$$RESETPower Conservation Commands Sleep mode control AT$$SLEEPENABLECurrent time AT$$TIME Software version AT$$SWVERExtended AT Commands Manual 2009-06-25 Low Battery Voltage Notification 1.3. RS232C Transceiver power-down control AT$$RS232PWRDOWNLED control AT$$EXTLED TE2 MT2 $$EXTLED?TE2 MT2 $$LOWBATTVTG? SMS low battery voltage set point AT$$LOWBATTVTGLow battery notification AT$$LOWBATT Receiving notification mode option AT$$RCVMODE Ringer volume control AT$$RINGLVLVisual/Audible Call Alert Options Ringer melody selection AT$$RINGIDXNetwork Relational Settings Roaming indicator information AT$$ROAMINDAntenna Signal Level report schedule AT$$ANTSET Antenna Signal Level AT$$ANTLVLReading MT2 state AT$$CURRSTATE Modem scheduled Information AT$$PingRssi inquiry AT$$RSSI TE2 MT2 $$LOCATION? RF information AT$$RFINFOLocation information AT$$LOCATION Diagnostic Commands Ring test AT$$DIAGRINGLED test AT$$DIAGLED Rssi LED response AT$$RSSILEVELLed Description CRTPKT TX/DTRData Call SET UP Data CallsCall released or failed Uses DTR pin MO data callGeneral Configuration Commands Select Message Service +CSMS+CSMS action command syntax Preferred Message Storage +CPMSMessage Service Failure Result Code +CMS Error Message Format +CMGFInformative Examples Message Configuration CommandsService Centre Address +CSCA Set Text Mode Parameters +CSMP Show Text Mode Parameters +CSDHMessage Receiving and Reading commands New Message Indications to TE +CNMIAlpha,scts,tooa,fo,pid,dcs,sca,tosca List Messages +CMGL Read Message +CMGR If text mode +CMGF=1, command successful and SMS-DELIVERIf text mode +CMGF=1, command successful and SMS-SUBMIT New Message Acknowledgement to ME/TA +CNMA ReportMessage Sending and Writing Commands Send Message +CMGSIf text mode +CMGF=1 If text mode +CMGF=1 and sending Send Message from Storage +CMSSSuccessful If sending failsSend Message Telstra SMS MO AT+MMC Write Message to Memory +CMGWSend Command +CMGC Delete Message +CMGDMore Messages to Send +CMMS AT+CNMI?AT+CMSS=7 SMS Send and Receive Options SMS Mail Notification Option SMSOPT=ABSMS Format send and receiveAT$$SMSOPT TE2 MT2 $$SMSOPT?SMS Mail Notification Option SMSOPT=1 SMS Mail Notification Option SMSOPT=2SMS Mail Notification Option SMSOPT=3 Illustrative exampleAuto delete Messages in ME Memory SMS NotificationsAuto Delete Messages in ME memory$$AUTODLTSMS SMS Notification $$SMSNOTIFSMS Auto Voltage Alert Auto Voltage Alert SMS Site Name AT$$SITENAMESMS $$LOWBATT 1 set point AT$$LOWBATTVTG TE2 MT2 $$SITENAME?SMS Remote Report Request Site Name AT$$REMOTECTRL SMS Remote Report RequestsSMS $$LOWBATT 1 set recipient number AT$$AUTOSMS 10.1.2.4 Rssi request Read ALL requestVbatt request Debug Screen request Location requestSwver request Remote Reset 73 Read command Enter directory number of specific MT2Enter message maxon.reset not case sensitive Value Modem will resetCommand User Remarks Profile NVM vs . US ER PR Ofile StorageTIA/EIA/IS 707A AT Command SET TE2 MT2 OK ErrorUser modified profiles & NVM changes User Profile store AT&WnBasic AT Commands Basic AT ParametersSTU IIIBasic S registers Basic action command set Extended AT Commands Manual 2009-06-25 Basic result codes Extended AT Command SetsExtended AT configuration command set +GCAP +GMI+GMM +GMR+ICF 8Data 1Stop DefaultSpace Default +IFC Circuit 133 Ready for Receiving DefaultCircuit 106 Clear to Send/Ready for Sending Default 115200bps. Default +IPRTE2 MT2 $$NOTIDS 13.1.1. RM3 AT$$NOTIDSTE2 MT2 $$NOTIDS? Cellular Extended AT Command SET Cellular AT parameter commands+CDS +CBC?Cellular identification AT command extensions +CGMI+CGMM +CGMRCellular result codes for Asynchronous data services DM Comman D Diagnostic Mode TE2 MT2 $$DBGSCRN Carrier Command OptionsDebug screen AT$$DBGSCRN
Related manuals
Manual 60 pages 51.94 Kb

MM-6280IND specifications

The Maxon Telecom MM-6280IND is a robust and versatile two-way radio designed to meet the demanding needs of professionals in various fields, including security, construction, and transportation. This model stands out for its combination of advanced features, reliable performance, and user-friendly interface, making it a preferred choice for organizations requiring efficient communication solutions.

One of the key features of the MM-6280IND is its long battery life. Equipped with a high-capacity lithium-ion battery, this radio can provide extended operational time, ensuring that users can stay connected throughout their shifts without frequent recharging interruptions. Additionally, the radio supports multiple battery-saving modes, allowing users to optimize power consumption according to their needs.

The MM-6280IND operates on multiple frequency bands, ensuring compatibility across various communication networks. It supports both analog and digital communication modes, making it adaptable to different environments and user preferences. This dual-mode capability enhances interoperability, allowing seamless communication with other radios, regardless of their technology.

In terms of audio quality, the MM-6280IND features advanced noise-cancellation technology. This ensures clear audio transmission even in noisy environments, such as construction sites or crowded events. Furthermore, the radio is equipped with a built-in speaker and microphone that deliver crisp and loud audio, allowing users to communicate effectively without straining their ears.

Durability is another hallmark of the MM-6280IND. The device is designed to withstand harsh conditions, featuring an IP65 rating for water and dust resistance. This makes it suitable for outdoor use, ensuring that it can function reliably, even in adverse weather conditions. The rugged construction of the radio also protects it from physical impacts, reducing the risk of damage from drops or bumps.

User-friendly functionality is prioritized in the MM-6280IND, with an intuitive keypad and a clear LCD display that make navigation straightforward. It also includes programmable buttons that allow users to customize settings and features according to their specific operational requirements.

Overall, the Maxon Telecom MM-6280IND is a high-performance two-way radio that combines longevity, durability, and adaptability. Its advanced communication technologies and user-focused design make it an excellent tool for professionals seeking efficient and reliable communication solutions in various industries. Whether used for coordinating team efforts or enhancing safety and security, the MM-6280IND is a valuable asset for any organization.