Getting Started
Before using this monitor, please make sure that the following items are included in your package: Multiscan 100sf/200sf monitor (1), power cord (1), HD15 (Female) - HD15 (Male without the No.9 pin) adapter (1), warranty card (1) and this operating instruction manual (1).
This monitor will sync with any IBM or compatible system equipped with VGA or greater graphics capability. Although this monitor will sync to other platforms running at horizontal frequencies between 30 and 70 kHz (Multiscan 100sf), 30 and 80kHz (Multiscan 200sf), including Macintosh and Power Macintosh system, a cable adapter is required. Please consult your dealer for advice on which adapter is suitable for your needs.
Step 1: With the computer switched off, attach the video signal cable to the video output.
IBM or compatible |
|
computer | to video output |
| HD15 - HD15 adapter may |
Apple computer | be required∗ |
| to video output |
| Macintosh adapter (not supplied) |
∗For the customers using IBM PC or IBM compatible system which is not compatible with DDC2AB and DDC2B+
This monitor uses a No.9 pin in the video signal connector for DDC2AB and DDC2B+ compatibility.
Some PC systems which are not compatible with either DDC2AB or DDC2B+ may not accept the No.9 pin. If you are not sure whether your PC system accepts the No.9 pin or not, use the HD15 (Female) - HD15 (Male without the No.9 pin) adapter (supplied). Make sure that the male side (without the No.9 pin) is connected to the computer.
Step 2: With the monitor switched off, attach the power
cord to the monitor and the other end to a power outlet.
Power cord (supplied)
to a power outlet
Step 3: Turn on the monitor and computer.
Step 4: If necessary, adjust the user controls according to your personal preference.
The installation of your Multiscan 100sf/200sf is complete. Enjoy your monitor.
1)VGA is a trademark of IBM Corporation.
2)VESA is a trademark of the
3)Macintosh is a trademark of Apple Computer Inc.
4)Windows® is a registered trademark of Microsoft Corporation in the United States and other countries.
Using Your Monitor
Preset and User Modes
The Multiscan 100sf/200sf has factory preset modes for the 7 most popular industry standards for true “plug and play” capability. For less common modes, the Multiscan 100sf/200sf ’s Digital Multiscan Technology will perform all of the complex adjustments necessary to ensure a high quality picture for any timing between
30 and 70Ê kHz (Multiscan 100sf ), 30 and 80Ê kHz (Multiscan 200sf ).
CPD-100SFT
No. | Resolution | Horizontal | Vertical | Graphic mode | ||
| (dots × lines) | frequency | frequency |
| ||
1 | 640 × 480 | 31.5 kHz | 60 Hz | VGA Graphic 1) | ||
2 | 800 × 600 | 46.9 kHz | 75 Hz | VESA 2) | ||
3 | 800 × 600 | 53.7 kHz | 85 Hz | VESA2) | ||
4 | 832 × 624 | 49.7 kHz | 75 Hz | Macintosh | ||
|
|
|
|
| 16” Color 3) | |
5 | 1024 | × 768 | 60.0 kHz | 75 Hz | VESA 2) | |
6 | 1024 | × 768 | 68.7 kHz | 85 Hz | VESA 2) | |
7 | 1280 | × 1024 | 64.0 kHz | 60 Hz | VESA 2) | |
|
|
|
| |||
|
|
|
|
| ||
No. | Resolution | Horizontal | Vertical | Graphic mode | ||
(dots ×lines) | frequency | frequency | ||||
|
| |||||
1 | 640 × 480 | 31.5 kHz | 60 Hz | VGA Graphic 1) | ||
2 | 800 × 600 | 46.9 kHz | 75 Hz | VESA 2) | ||
3 | 800 × 600 | 53.7 kHz | 85 Hz | VESA2) | ||
4 | 832 × 624 | 49.7 kHz | 75 Hz | Macintosh | ||
|
|
|
|
| 16” Color 3) | |
5 | 1024 | × 768 | 60.0 kHz | 75 Hz | VESA 2) | |
6 | 1024 | × 768 | 60.2 kHz | 75 Hz | Macintosh | |
|
|
|
|
| 19” Color 3) | |
7 | 1024 | × 768 | 68.7 kHz | 85 Hz | VESA 2) | |
8 | 1152 | × 870 | 68.7 kHz | 75 Hz | Macintosh | |
|
|
|
|
| 21” Color 3) | |
9 | 1280 | × 1024 | 80.0 kHz | 75 Hz | VESA 2) |
For the customers using the Windows® 4) 95
Install the new model information of the Sony computer display from “Windows 95 Monitor Information Disk” into your PC. (To install the file, refer to the attached “About the Windows 95 Monitor Information Disk/File”).
This monitor complies with “VESA DDC,” the standards of Plug&Play. If your PC/graphic board complies with DDC, select “Plug and Play Monitor (VESA DDC)” or this monitor’s model name
Recommended horizontal timing conditions
Horizontal sync width should be: >1.0 µsec.
Horizontal blanking width should be: >3.6 µsec. (Multiscan 100sf)/ >3.0 µsec. (Multiscan 200sf)
Vertical sync width should be: < 560 µsec.
Note