nTier700 BlueScale Firmware
BlueScale2.6.0.7
This release improves the overall reliability of the nTier700.
Resolved Issues
The File Migrator installation files have been added to system disk on the the
Note: As of BlueScale 2.7.1.7, File Migrator is no longer included with the nTier700.
Known Issue
Problem | Workaround | |
|
| |
When RAIDs are rebuilding, the | If you need to determine the status of the RAID rebuild, do | |
Bluescale progress screen does not | one of the following: | |
update to reflect the actual progress, | | Monitor the BlueScale messages. The rebuild is complete |
even when the process is nearly |
| when you see a message similar to this: |
complete. |
| Raid <raid name> in Enclosure <Enclosure #> |
Note: This issue is resolved in BlueScale |
| |
| Chassis <Chassis #> Hba <Hba #> Expander | |
2.7.1.7. |
| <Expander #> changed state from <previous |
|
| state> to OK |
| | Use the Windows command line to determine the status. |
| 1. Connect to the Windows desktop. | |
| 2. Select Start > Accessories > Command Prompt to open a | |
|
| command prompt window. |
| 3. Type the following command: | |
|
| %ntiercurrent%\adaptec\arcconf.exe getstatus |
|
| <ctrl #> |
|
| where <ctrl #> is the number of the RAID controller on |
|
| which the RAID was being rebuilt (either 1 or 2). |
| 4. Repeat Step 2 until the status returned is “None.” | |
|
|
|
16
Release Notes | 90990019 |