FEED GATE LATCH ADJUSTMENT

NOTE: Adjustment is made by tightening or loosening the TENSION ADJUSTMENT NUT with the feed gate in the up position. Spring tension should not exceed 5 lbs to prevent excessive wear on the feed gate latch and striker.

FEED GATE

STRIKER

TENSION

ADJUSTMENT

NUT

SPRING

FEED GATE

LATCH

BALE DOOR

BOLTS

FOR

STRIKER

NOTE: In the event of excessive wear, the feed gate latch STRIKER is removable and replaceable. Striker may be replaced by removing the two (2) striker bolts. Access to the striker bolts can be achieved by removing the front cover from the bale door

2-7

Image 20
Contents Play IT Safe VERNON, AL FAYETTE, AL YERINGTON, NV CLEARFIELD, PAContents Operation EC Declaration of Conformity Stand Clear While Baler is in Operation PRE-OPERATING InstructionsControls ON-OFF Keyed Selector Switch Control DescriptionOperating Instructions Making a Bale To Make a BaleOperating Instructions Bale TIE OFF/BALE Eject For Bale TIE OFF & Bale EjectDiagram Bale TIE OFF/BALE Eject Front View of BalerSide View BaleTIE Slot Cleaning Slot Cleaning Tool Front ViewDecals Decal Placement 460400 Supporting of Platen Periodic Maintenance Annual Filter MaintenanceMonthly Three MonthsPressure Setting Hydraulic System Pressure SettingPressure Setting and Interlock Testing Magnetic Interlock TestingCylinder Rebuilding Cylinder Removal and RebuildingCylinder Removal Feed Gate Latch Adjustment Operating Characteristics Principles of OperationCharts Electrical Requirements VoltagePanel BOX Power Unit Electrical Schematic Hydraulic Schematic 0489Parts List Recommended OilsInstallation General InstallationAnchoring to Concrete PAD Electrical Installation Grounding InstructionsMotor Rotation Applies to Three Phase Units only START-UP Instructions