4.7Calibration Mode – Button Functions
In ‘Calibration’ mode, the buttons allow the printer to adjust to the media being used. Calibration can be performed either automatically or manually, as detailed below.
;Notes: Before calibrating, ensure that the Printhead Carrier Assembly is latched down, that the cover is closed, and that the media sensor has been set for the appropriate media type, see Section 4.5.2.
Printer and cutter faults are disabled during and , but can still occur while printing “test” labels.
If at any time you wish to discard your changes and revert back to the previous calibration simply turn off power to the printer. Also, Factory Defaults can be restored, see Section 5.7
To perform Calibration:
CANCEL (Press and hold during
Calibration Mode
PAUSE |
|
|
|
| |
Auto Media Calibration (See section 4.7.1) | |||||
FEED (PressReleaseand)Feeds one label for “test” | |||||
FEED | ( | Press and | ) | (Until Paused light turns off) | |
Hold |
| ||||
|
| ||||
CANCEL Prints the ‘Test Label’ for “test” | |||||
PAUSE | Saves the current values | ||||
+ | |||||
and resumes Normal Mode | |||||
CANCEL | |||||
|
|
|
|
Media Sensor Calibration(See section 4.7.2)
PAUSE | Analyze for ‘Paper’ | |
FEED Analyze for ‘Backing or ‘Mark’ | ||
CANCEL Analyze ‘Out of Media’ condition | ||
PAUSE | Accepts the current | |
+ | ||
values for “test” | ||
CANCEL | ||
|
30 |
|