4.7.1 Auto Media Sensor Calibration
Auto Media Sensor Calibration automatically establishes the optimum sensing values for the media you are using in the printer.
;Note: Before calibrating, be sure the media sensor is set for the appropriate media type, see Section 4.5.2; also, ensure that the Printhead Carrier Assembly is latched down and the cover is closed.
To automatically calibrate the media sensor:
1.With the desired media loaded, hold the CANCEL button while powering up the printer. Continue to hold the button until the STOP light turns off then release it.
2.Next press the PAUSE button. The printer will feed approximately ten inches of media to calculate the TOF Delta and Low values to be used.
3.Upon completion, one of the following lights will flash five times to denote the result of the auto calibration attempt:
STOP light = Successful calibration. Proceed to Step 4.
ERROR light = Unsuccessful calibration, try again. If the calibration continues to fail proceed to Section 4.7.2.
;Note: If you wish to discard the changes and revert back to the previous calibration simply turn off the printer before Step 4.
4.Now save the changes and resume by pressing the PAUSE + CANCEL buttons simultaneously and briefly. Wait until the STOP light goes off.