GS ^ n1 n2 n3
[Function] | Executing the macro | ||
[Code] | <1D>H<5E>H<n1><n2><n3> | ||
[Range] | 0 | n1 | 255 |
| 0 | n2 | 255 |
| 0 | n3 | 1 |
[Outline] | Executing contents defined in macro. |
| n1 : The number of times of macro execution |
| n2 : Waiting time on macro execution |
| Waiting time of n2 ⋅ 100 msec is given for every execution. |
| n3 : Macro execution mode |
| n3=0 Continuous execution: |
| The Macro is executed “n1” times continuously at the |
| time interval specified by “n2”. |
| n3=1 Execution by FEED Switch: |
| After waiting for the time specified by “n2”, the |
| ARARM LED flickers and the FEED switch is waiting to |
| be pressed. When it is pressed, the macro is executed |
| once. This action is repeated “n1” times. |
[Caution] | • When this command is received while in macro definition, |
| suspension of macro definition is indicated. At this time, the |
| defined content is cleared. |
| • No execution takes place when the macro is held undefined |
| or n1=0. |
| • While in macro execution with n3=1, paper feed with the FEED |
| switch is not available. |
[Default] | The initial value is not defined. |
[See Also] | GS : |
[Sample Program] | Refer to Sample Program and Print Results for GS: on page 62. |