Chapter 2 PrinterOparetion
5 System Maintenance Mode
∗1 Native
Normally ‘NativeON’ is used. See the Command Reference for details.
∗2 Feed amount
See the Command Reference for details.
∗3 Command code
Normally ‘CmndSTD’ is used. See the Command Reference for details.
∗4 For adjustable sensor, the voltage setting must be done each time ‘AJSensOF’ is changed to ‘AJSensON, and vice versa.
∗5 Voltage setting
In the voltage setting, adjust the paper gap and black line adjustment controls so that the voltages of both ‘PE’ and ‘BL’ displayed on the LCD screen can read 3.0V to 3.3V.
1.Set the liner (glassine paper) only that has been removed from the label. (For th eblack line paper, position the black line so that it does not come to the paper sensor.)
2.Set each level to 3.0V to 3.3V with the controls.
Paper gap sensor adjustment control
Black line sensor adjustment control
28