AMCC 9550SX, 9500S, 9590SE, 9650SE manual Cx show

Page 36

Chapter 2. CLI Syntax Reference

/cx set autorebuild=onoff

(9550SX, 9590SE, 9650SE)

/cx

set

autodetect=onoff disk=<p:-p>all

only)

/cx

set

verify=enabledisable1..5

(9000

/cx set selftest=enabledisable [task=UDMASMART](9000 only)

/cx flush

/cx update fw=filename_with_path [force] (9000 only)

/cx commit

(Windows only. Also known as shutdown)

/cx start mediascan

(7000/8000 only)

/cx

stop mediascan

(7000/8000 only)

/cx

rescan [noscan]

(Does not import non-JBOD on 7000/8000

 

models.

 

/cx show

This command shows summary information on the specified controller /cx.

This information is organized into a report containing two to three parts:

A Unit summary listing all present units

A Port summary section listing of all ports and disks attached to them.

A BBU summary section listing, if a BBU is installed on the controller.

The Unit summary section lists all present unit and specifies their unit number, unit type (such as RAID 5), unit status (such as INITIALIZING), %R (percent completion of rebuilding), % V/I/M (percent completion of verifying, initializing, or migrating), stripe size, size (usable capacity) in gigabytes or terabytes, and the auto-verify policy status (on/off)

Possible unit statuses include OK, RECOVERY, INOPERABLE, UNKNOWN, DEGRADED, INITIALIZING, INIT-PAUSED, VERIFYING, VERIFY-PAUSED, REBUILDING, REBUILD-PAUSED, MIGRATING, and MIGRATE-PAUSED. Definitions of the unit statuses are available in the 3ware Serial ATA RAID Controller User Guide.

Note: If an asterisk (*) appears next to the status of a unit, there is an error on one of the drives in the unit. This feature provides a diagnostic capability for potential problem drives. The error may not be a repeated error, and may be caused by an ECC error, SMART failure, or a device error. Rescanning the controller will clear the drive error status if the condition no longer exists.

The Port summary section lists all present ports and specifies the port number, disk status, unit affiliation, size (in gigabytes) and blocks (512 bytes), and the serial number assigned by the disk vendor.

The BBU summary lists details about the BBU, if one is installed. It includes a few important attributes such as hours left (in which the current BBU can

30

3ware Serial ATA RAID Controller CLI Guide

Image 36
Contents Command Line Interface 3ware Serial ATA RAID ControllerCopyright Table of Contents 3ware Serial ATA RAID Controller CLI Guide Cx/ux set autoverify=onoff 3ware Serial ATA RAID Controller CLI Guide About this CLI Guide Introduction to the 3ware Command Line Interface Features of the CLISupported Operating Systems TerminologyInstalling the 3ware CLI Installing the 3ware CLI on WindowsTo install 3ware CLI on Windows Permissions Required to Run CLIInstalling the 3ware CLI on Linux and FreeBSD To start CLI, do one of the followingUsing the command interface interactively Working with 3ware CLITo use the CLI interactively Using a single command with output Using an input file to execute a scriptScripting example Outputting the CLI to a Text File ConventionsUnderstanding RAID Levels and Concepts RAID ConceptsAvailable RAID Configurations RAIDRAID 1 Configuration Example RAID 5 Configuration Example RAID 6 Configuration Example RAID 10 Configuration Example Single Disk JbodRAID Configuration Types Possible Configurations Based on Number of DrivesDetermining What RAID Level to Use Hot SpareUsing Drive Capacity Efficiently Drive CapacitySupport for Over 2 Terabytes Common Tasks Mapped to CLI Commands CLI Syntax ReferenceCLI Syntax Reference Syntax Overview Port TasksC1 add type=raid1 disk=0-1 Shell Object Commands Focus ObjectShow ExampleShow ver Show alarms reverse Show diagShow rebuild Show verify Show selftestFlush RescanCommit Controller Object Commands Cx showCx show Cx show attribute attribute Cx show bios Cx show driverCx show model Cx show firmwareCx show serial Cx show pcbCx show pchip Cx show achipCx show numports Cx show numunitsCx show ctlbus Cx show exportjbodCx show spinup Cx show staggerCx show ondegrade Cx show autocarveCx show carvesize Cx show memoryCx show autorebuild Cx show unitstatusCx show allunitstatus Cx show drivestatusCx show all 3JV3MVTASupported RAID Types Supported Stripe Sizes KB Supported Model-Unit Types for ignoreECC Cx rescan noscan Cx commit Cx flushCx show alarms reverse Cx show diag Cx show rebuildRAID-5 Initializing Cx show verify Cx show selftest Setting Up a Rebuild Schedule Cx add rebuild=dddhhdurationSetting Up a Verify Schedule Cx add verify=dddhhdurationSetting Up a Selftest Schedule Cx add selftest=dddhhCx set rebuild=enabledisable1..5 Cx del rebuild=slotidCx del verify=slotid Cx del selftest=slotidCx set verify=enabledisable1..5 Cx set selftest=enabledisable task=UDMASMARTCx set exportjbod=onoff Cx set ondegrade=cacheofffollowCx set spinup=nn Cx set stagger=nn Cx set autocarve=onoffCx set carvesize=1024..2048 Cx set autorebuild=onoff Cx set autodetect=onoff disk=p-pallCx start mediascan Unit Object Commands Cx stop mediascanCx/ux show Cx/ux show status Cx/ux show rebuildstatusCx/ux show verifystatus Cx/ux show initializestatus Cx/ux show nameCx/ux show serial Cx/ux show qpolicyCx/ux show storsave Cx/ux show identifyCx/ux show autoverify Cx/ux show cacheCx/ux show volumes Cx/ux show ignoreECCCx/ux show all Cx/ux remove noscan quiet Cx/ux del noscan quiet Cx/ux start rebuild disk=pp-p...ignoreECCCx/ux start verify Cx/ux pause rebuildCx/ux resume rebuild Supported RAID Logical Unit Types for VerificationCx/ux stop verify Cx/ux flushCx/ux set autoverify=onoff Cx/ux set cache=onoff quietCx/ux set identify=onoff Cx/ux set ignoreECC=onoffSupported RAID Types for Caching Cx/ux set name=string Cx/ux set qpolicy=onoffCx/ux set storsave=protectbalanceperform quiet Example 3ware Serial ATA RAID Controller CLI Guide Valid Migration Paths Supported Stripe Sizes Migration Process Example of splitting a mirrorExample of capacity expansion Example of migrate output Port Object Commands Cx/px showCx/px show status Cx/px show modelCx/px show serial Cx/px show firmwareCx/px show ncq Cx/px show lspeedCx/px show capacity Cx/px show smartCx/px show all Cx/px remove noscan quiet Cx/px set identify=onoffBBU Object Commands Cx/bbu showCx/bbu show attribute attribute Cx/bbu show statusCx/bbu show batinst Cx/bbu show lasttestCx/bbu show volt Cx/bbu show tempCx/bbu show bootloader Cx/bbu show serialCx/bbu show fw Cx/bbu show pcbCx/bbu enable Cx/bbu disable quietCx/bbu test quiet Enclosure Object Commands Ex showEx show attribute attribute Ex show controllersEx show slots Ex show fansEx show temp Ex show allEx/slotx show Ex/slotx show identifyEx/slotx set identify=onoff Help Commands Help with specific commandsEx/fanx show Ex/tempx showAttribute attribute Help with attributes HelpHelp update Help showHelp flush Help rescanHelp focus Help /cxHelp /cx/ux Help /cx/pxCommand Logging Return CodeHelp /ex/fanx Help /ex/tempxIf you type