AMCC 9550SX, 9500S, 9590SE, 9650SE manual Supported Model-Unit Types for ignoreECC

Page 48

Chapter 2. CLI Syntax Reference

grouped into groups of 3 or 5 drives. For 16 disks, the disks can be grouped into groups of 4 or 8 drives.

noscan attribute instructs CLI not to notify the operating system of the creation of the new unit. By default CLI will inform the operating system. One application of this feature is to prevent the operating system from creating block special devices such as /dev/sdb and /dev/sdc as some implementations might create naming fragmentation and a moving target.

nocache attribute instructs CLI to disable the write cache on the newly created unit. Enabling write cache increases write performance at the cost of potential data loss in case of sudden power loss (unless a BBU or UPS is installed). By default the cache is enabled. To avoid the possibility of data loss in the event of a sudden power loss, it is recommended not to set nocache unless there is a BBU (battery backup unit) or UPS (uninterruptible power supply) installed.

autoverify attribute enables the autoverify attribute on the unit that is to be created. For more details on this feature, see “/cx/ux set autoverify=onoff” on page 68. This feature is not supported on model 7000/8000. On model 9000, the JBOD autoverify attribute is not persistent (does not survive reboots).

noqpolicy attribute instructs CLI to disable the qpolicy (drive queuing) on the newly created unit. The default is for the qpolicy to be on (in other words, noqpolicy is not specified). For a spare unit, specifying noqpolicy has no effect and the default remains. If the spare unit becomes a true unit, it would adopt the qpolicy of the “new” unit. For JBOD, the qpolicy cannot be set during unit creation, and specifying noqpolicy returns an error. For more about drive queuing, see “/cx/ux show qpolicy” on page 62 and “/cx/ux set qpolicy=onoff” on page 70.

ignoreECC attribute enables the ignoreECC/OverwriteECC attribute on the unit that is to be created. For more details on this feature, see “/cx/ux set ignoreECC=onoff” on page 69. The following table illustrates the supported Model-Unit Types. This table only applies to setting this feature at unit creation time. IgnoreECC only applies to redundant units. For the 7/8000 series, this setting is only applicable during rebuild; it is not applicable during creation.

Table 8: Supported Model-Unit Types for ignoreECC

Model

R-0

R-1

R-5

R-6

R-10

R-50

Single

JBOD

Spare

 

 

 

 

 

 

 

 

 

 

7K/8K

No

No

No

N/A

No

No

No

No

No

 

 

 

 

 

 

 

 

 

 

9000a

No

Yes

Yes

N/A

Yes

Yes

No

No

No

9650SE

No

Yes

Yes

Yes

Yes

Yes

No

No

No

 

 

 

 

 

 

 

 

 

 

a. Models 9500S, 9550SX, and 9590SE

42

3ware Serial ATA RAID Controller CLI Guide

Image 48
Contents Command Line Interface 3ware Serial ATA RAID ControllerCopyright Table of Contents 3ware Serial ATA RAID Controller CLI Guide Cx/ux set autoverify=onoff 3ware Serial ATA RAID Controller CLI Guide About this CLI Guide Introduction to the 3ware Command Line Interface Features of the CLISupported Operating Systems TerminologyInstalling the 3ware CLI Installing the 3ware CLI on WindowsTo install 3ware CLI on Windows Permissions Required to Run CLIInstalling the 3ware CLI on Linux and FreeBSD To start CLI, do one of the followingUsing the command interface interactively Working with 3ware CLITo use the CLI interactively Using a single command with output Using an input file to execute a scriptScripting example Outputting the CLI to a Text File ConventionsUnderstanding RAID Levels and Concepts RAID ConceptsAvailable RAID Configurations RAIDRAID 1 Configuration Example RAID 5 Configuration Example RAID 6 Configuration Example RAID 10 Configuration Example Single Disk JbodRAID Configuration Types Possible Configurations Based on Number of DrivesDetermining What RAID Level to Use Hot SpareUsing Drive Capacity Efficiently Drive CapacitySupport for Over 2 Terabytes Common Tasks Mapped to CLI Commands CLI Syntax ReferenceCLI Syntax Reference Syntax Overview Port TasksC1 add type=raid1 disk=0-1 Shell Object Commands Focus ObjectShow ExampleShow ver Show alarms reverse Show diagShow rebuild Show verify Show selftestFlush RescanCommit Controller Object Commands Cx showCx show Cx show attribute attribute Cx show bios Cx show driverCx show model Cx show firmwareCx show serial Cx show pcbCx show pchip Cx show achipCx show numports Cx show numunitsCx show ctlbus Cx show exportjbodCx show spinup Cx show staggerCx show ondegrade Cx show autocarveCx show carvesize Cx show memoryCx show autorebuild Cx show unitstatusCx show allunitstatus Cx show drivestatusCx show all 3JV3MVTASupported RAID Types Supported Stripe Sizes KB Supported Model-Unit Types for ignoreECC Cx rescan noscan Cx commit Cx flushCx show alarms reverse Cx show diag Cx show rebuildRAID-5 Initializing Cx show verify Cx show selftest Setting Up a Rebuild Schedule Cx add rebuild=dddhhdurationSetting Up a Verify Schedule Cx add verify=dddhhdurationSetting Up a Selftest Schedule Cx add selftest=dddhhCx set rebuild=enabledisable1..5 Cx del rebuild=slotidCx del verify=slotid Cx del selftest=slotidCx set verify=enabledisable1..5 Cx set selftest=enabledisable task=UDMASMARTCx set exportjbod=onoff Cx set ondegrade=cacheofffollowCx set spinup=nn Cx set stagger=nn Cx set autocarve=onoffCx set carvesize=1024..2048 Cx set autorebuild=onoff Cx set autodetect=onoff disk=p-pallCx start mediascan Unit Object Commands Cx stop mediascanCx/ux show Cx/ux show status Cx/ux show rebuildstatusCx/ux show verifystatus Cx/ux show initializestatus Cx/ux show nameCx/ux show serial Cx/ux show qpolicyCx/ux show storsave Cx/ux show identifyCx/ux show autoverify Cx/ux show cacheCx/ux show volumes Cx/ux show ignoreECCCx/ux show all Cx/ux remove noscan quiet Cx/ux del noscan quiet Cx/ux start rebuild disk=pp-p...ignoreECCCx/ux start verify Cx/ux pause rebuildCx/ux resume rebuild Supported RAID Logical Unit Types for VerificationCx/ux stop verify Cx/ux flushCx/ux set autoverify=onoff Cx/ux set cache=onoff quietCx/ux set identify=onoff Cx/ux set ignoreECC=onoffSupported RAID Types for Caching Cx/ux set name=string Cx/ux set qpolicy=onoffCx/ux set storsave=protectbalanceperform quiet Example 3ware Serial ATA RAID Controller CLI Guide Valid Migration Paths Supported Stripe Sizes Migration Process Example of splitting a mirrorExample of capacity expansion Example of migrate output Port Object Commands Cx/px showCx/px show status Cx/px show modelCx/px show serial Cx/px show firmwareCx/px show ncq Cx/px show lspeedCx/px show capacity Cx/px show smartCx/px show all Cx/px remove noscan quiet Cx/px set identify=onoffBBU Object Commands Cx/bbu showCx/bbu show attribute attribute Cx/bbu show statusCx/bbu show batinst Cx/bbu show lasttestCx/bbu show volt Cx/bbu show tempCx/bbu show bootloader Cx/bbu show serialCx/bbu show fw Cx/bbu show pcbCx/bbu enable Cx/bbu disable quietCx/bbu test quiet Enclosure Object Commands Ex showEx show attribute attribute Ex show controllersEx show slots Ex show fansEx show temp Ex show allEx/slotx show Ex/slotx show identifyEx/slotx set identify=onoff Help Commands Help with specific commandsEx/fanx show Ex/tempx showAttribute attribute Help with attributes HelpHelp update Help showHelp flush Help rescanHelp focus Help /cxHelp /cx/ux Help /cx/pxCommand Logging Return CodeHelp /ex/fanx Help /ex/tempxIf you type