Chapter 2. CLI Syntax Reference

For operating systems that support units larger than 2TB, there is no need to set the policy to on unless you want the operating system to have multiple smaller volumes.

If you use a 32-bit operating system, it is recommended that you keep the policy on unless you know that your operating system supports disks that are larger than 2 TB.

When the autocarve policy is off, all newly created units will consist of one single volume.

Example:

//localhost> /c0 show autocarve /c0 Auto-Carving Policy = on

/cx show carvesize

This feature only applies to 9000 series controllers.

This command shows the maximum size of the volumes that will be created if the autocarve policy is set to on. The carvesize can be set between 1024 GB and 2048 GB. Default carvesize is 2048 GB (2 TB). For more information see, “/cx show autocarve” above.

Example:

//localhost> /c0 show carvesize /c0 Auto-Carving Size = 2000 GB

/cx show memory

This command reports the size of the memory installed on the controller.

Note: The 9500S controllers ship with 128 MBytes of cache, yet only 112MB shows as memory installed. The other 16 MB is reserved for use by the controller.

Example:

//localhost> /c0 show memory /c0 Memory Installed = 112MB

36

3ware Serial ATA RAID Controller CLI Guide

Image 42
Contents Command Line Interface 3ware Serial ATA RAID ControllerCopyright Table of Contents 3ware Serial ATA RAID Controller CLI Guide Cx/ux set autoverify=onoff 3ware Serial ATA RAID Controller CLI Guide About this CLI Guide Introduction to the 3ware Command Line Interface Features of the CLISupported Operating Systems TerminologyTo install 3ware CLI on Windows Installing the 3ware CLIInstalling the 3ware CLI on Windows Permissions Required to Run CLIInstalling the 3ware CLI on Linux and FreeBSD To start CLI, do one of the followingUsing the command interface interactively Working with 3ware CLITo use the CLI interactively Using a single command with output Using an input file to execute a scriptScripting example Outputting the CLI to a Text File ConventionsUnderstanding RAID Levels and Concepts RAID ConceptsAvailable RAID Configurations RAIDRAID 1 Configuration Example RAID 5 Configuration Example RAID 6 Configuration Example RAID 10 Configuration Example Single Disk JbodDetermining What RAID Level to Use RAID Configuration TypesPossible Configurations Based on Number of Drives Hot SpareUsing Drive Capacity Efficiently Drive CapacitySupport for Over 2 Terabytes Common Tasks Mapped to CLI Commands CLI Syntax ReferenceCLI Syntax Reference Syntax Overview Port TasksC1 add type=raid1 disk=0-1 Shell Object Commands Focus ObjectShow ExampleShow ver Show alarms reverse Show diagShow rebuild Show verify Show selftestFlush RescanCommit Controller Object Commands Cx showCx show Cx show attribute attribute Cx show model Cx show biosCx show driver Cx show firmware Cx show pchip Cx show serial Cx show pcb Cx show achipCx show ctlbus Cx show numportsCx show numunits Cx show exportjbodCx show ondegrade Cx show spinupCx show stagger Cx show autocarveCx show carvesize Cx show memoryCx show autorebuild Cx show unitstatusCx show allunitstatus Cx show drivestatusCx show all 3JV3MVTASupported RAID Types Supported Stripe Sizes KB Supported Model-Unit Types for ignoreECC Cx rescan noscan Cx commit Cx flushCx show alarms reverse Cx show diag Cx show rebuildRAID-5 Initializing Cx show verify Cx show selftest Setting Up a Rebuild Schedule Cx add rebuild=dddhhdurationSetting Up a Verify Schedule Cx add verify=dddhhdurationSetting Up a Selftest Schedule Cx add selftest=dddhhCx del verify=slotid Cx set rebuild=enabledisable1..5Cx del rebuild=slotid Cx del selftest=slotidCx set verify=enabledisable1..5 Cx set selftest=enabledisable task=UDMASMARTCx set exportjbod=onoff Cx set ondegrade=cacheofffollowCx set spinup=nn Cx set stagger=nn Cx set autocarve=onoffCx set carvesize=1024..2048 Cx set autorebuild=onoff Cx set autodetect=onoff disk=p-pallCx start mediascan Unit Object Commands Cx stop mediascanCx/ux show Cx/ux show status Cx/ux show rebuildstatusCx/ux show verifystatus Cx/ux show serial Cx/ux show initializestatusCx/ux show name Cx/ux show qpolicyCx/ux show autoverify Cx/ux show storsaveCx/ux show identify Cx/ux show cacheCx/ux show volumes Cx/ux show ignoreECCCx/ux show all Cx/ux remove noscan quiet Cx/ux del noscan quiet Cx/ux start rebuild disk=pp-p...ignoreECCCx/ux resume rebuild Cx/ux start verifyCx/ux pause rebuild Supported RAID Logical Unit Types for VerificationCx/ux set autoverify=onoff Cx/ux stop verifyCx/ux flush Cx/ux set cache=onoff quietCx/ux set identify=onoff Cx/ux set ignoreECC=onoffSupported RAID Types for Caching Cx/ux set name=string Cx/ux set qpolicy=onoffCx/ux set storsave=protectbalanceperform quiet Example 3ware Serial ATA RAID Controller CLI Guide Valid Migration Paths Supported Stripe Sizes Migration Process Example of splitting a mirrorExample of capacity expansion Example of migrate output Port Object Commands Cx/px showCx/px show serial Cx/px show statusCx/px show model Cx/px show firmwareCx/px show capacity Cx/px show ncqCx/px show lspeed Cx/px show smartCx/px show all Cx/px remove noscan quiet Cx/px set identify=onoffBBU Object Commands Cx/bbu showCx/bbu show attribute attribute Cx/bbu show statusCx/bbu show volt Cx/bbu show batinstCx/bbu show lasttest Cx/bbu show tempCx/bbu show fw Cx/bbu show bootloaderCx/bbu show serial Cx/bbu show pcbCx/bbu enable Cx/bbu disable quietCx/bbu test quiet Enclosure Object Commands Ex showEx show attribute attribute Ex show controllersEx show temp Ex show slotsEx show fans Ex show allEx/slotx show Ex/slotx show identifyEx/slotx set identify=onoff Ex/fanx show Help CommandsHelp with specific commands Ex/tempx showAttribute attribute Help with attributes HelpHelp flush Help updateHelp show Help rescanHelp /cx/ux Help focusHelp /cx Help /cx/pxHelp /ex/fanx Command LoggingReturn Code Help /ex/tempxIf you type