AMCC 9650SE, 9550SX, 9500S, 9590SE manual Supported Stripe Sizes KB

Page 47

Controller Object Commands

stripe=Stripe consists of the stripe size to be used. The following table illustrates the supported and applicable stripes on unit types and controller models. Stripe size units are in K (kilobytes). If no stripe size is specified, 64K is used by default, if applicable. If you need to change the stripe size after the unit is created, you can do so my migrating the unit.

Table 7: Supported Stripe Sizes (KB)

Model

R0

R1

R5

R6

R10

JBOD

Spare

R50

Single

 

 

 

 

 

 

 

 

 

 

7K/8K

64

N/A

64

N/S

64

N/A

N/A

N/S

N/S

 

 

 

 

 

 

 

 

 

 

 

128

 

 

 

128

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

256

 

 

 

256

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

512

 

 

 

512

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1024

 

 

 

1024

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9000a

16

N/A

16

N/S

16

N/A

N/A

16

N/A

 

64

 

64

 

64

 

 

64

 

 

 

 

 

 

 

 

 

 

 

 

256

 

256

 

256

 

 

256

 

 

 

 

 

 

 

 

 

 

 

9650SE

16

N/A

16

 

16

N/A

N/A

16

N/A

 

 

 

 

 

 

 

 

 

 

 

64

 

64

64

64

 

 

64

 

 

 

 

 

 

 

 

 

 

 

 

256

 

256

 

256

 

 

256

 

 

 

 

 

 

 

 

 

 

 

a. Models 9500S, 9550SX, and 9590SE

group=345678 indicates the number of disks per group for a RAID 50 type. (This attribute can only be used when type=raid50.) Recall that a RAID 50 is a multi-tier array. At the bottom-most layer, N number of disks per group are used to form the RAID 5 layer. These RAID 5 arrays are then integrated into a RAID 0. This attribute allows you to specify the number of disks in the RAID 5 level. Valid values are 3, 4, 5, 6, 7, and 8.

Note that a sufficient number of disks are required for a given pattern or disk group. For example, given 6 disks, specifying 3 will create two RAID 5 arrays. With 12 disks, specifying 3 will create four RAID 5 arrays under the RAID 0 level. With only 6 disks a grouping of 6 is not allowed, as you would basically be creating a RAID 5.

The default RAID 50 grouping varies, based on number of disks. For 6 and 9 disks, default grouping is 3. For 8 disks, the default grouping is 4. For 10 disks, the default grouping is 5, and for 12 disks, the disks can be grouped into groups of 3, 4, or 6 drives (the group of 4 drives is set by default as it provides the best of net capacity and performance). For 15 disks, the disks can be

www.3ware.com

41

Image 47
Contents 3ware Serial ATA RAID Controller Command Line InterfaceCopyright Table of Contents 3ware Serial ATA RAID Controller CLI Guide Cx/ux set autoverify=onoff 3ware Serial ATA RAID Controller CLI Guide About this CLI Guide Features of the CLI Introduction to the 3ware Command Line InterfaceTerminology Supported Operating SystemsPermissions Required to Run CLI Installing the 3ware CLIInstalling the 3ware CLI on Windows To install 3ware CLI on WindowsTo start CLI, do one of the following Installing the 3ware CLI on Linux and FreeBSDTo use the CLI interactively Using the command interface interactivelyWorking with 3ware CLI Scripting example Using a single command with outputUsing an input file to execute a script Conventions Outputting the CLI to a Text FileRAID Concepts Understanding RAID Levels and ConceptsRAID Available RAID ConfigurationsRAID 1 Configuration Example RAID 5 Configuration Example RAID 6 Configuration Example RAID 10 Configuration Example Jbod Single DiskHot Spare RAID Configuration TypesPossible Configurations Based on Number of Drives Determining What RAID Level to UseDrive Capacity Using Drive Capacity EfficientlySupport for Over 2 Terabytes CLI Syntax Reference Common Tasks Mapped to CLI CommandsCLI Syntax Reference Port Tasks Syntax OverviewC1 add type=raid1 disk=0-1 Focus Object Shell Object CommandsExample ShowShow ver Show rebuild Show alarms reverseShow diag Show selftest Show verifyCommit FlushRescan Cx show Controller Object CommandsCx show Cx show attribute attribute Cx show firmware Cx show biosCx show driver Cx show modelCx show achip Cx show serialCx show pcb Cx show pchipCx show exportjbod Cx show numportsCx show numunits Cx show ctlbusCx show autocarve Cx show spinupCx show stagger Cx show ondegradeCx show memory Cx show carvesizeCx show unitstatus Cx show autorebuild Cx show drivestatus Cx show allunitstatus3JV3MVTA Cx show allSupported RAID Types Supported Stripe Sizes KB Supported Model-Unit Types for ignoreECC Cx rescan noscan Cx flush Cx commitCx show alarms reverse Cx show rebuild Cx show diagRAID-5 Initializing Cx show verify Cx show selftest Cx add rebuild=dddhhduration Setting Up a Rebuild ScheduleCx add verify=dddhhduration Setting Up a Verify ScheduleCx add selftest=dddhh Setting Up a Selftest ScheduleCx del selftest=slotid Cx set rebuild=enabledisable1..5Cx del rebuild=slotid Cx del verify=slotidCx set selftest=enabledisable task=UDMASMART Cx set verify=enabledisable1..5Cx set spinup=nn Cx set exportjbod=onoffCx set ondegrade=cacheofffollow Cx set carvesize=1024..2048 Cx set stagger=nnCx set autocarve=onoff Cx set autodetect=onoff disk=p-pall Cx set autorebuild=onoffCx start mediascan Cx stop mediascan Unit Object CommandsCx/ux show Cx/ux show verifystatus Cx/ux show statusCx/ux show rebuildstatus Cx/ux show qpolicy Cx/ux show initializestatusCx/ux show name Cx/ux show serialCx/ux show cache Cx/ux show storsaveCx/ux show identify Cx/ux show autoverifyCx/ux show all Cx/ux show volumesCx/ux show ignoreECC Cx/ux remove noscan quiet Cx/ux start rebuild disk=pp-p...ignoreECC Cx/ux del noscan quietSupported RAID Logical Unit Types for Verification Cx/ux start verifyCx/ux pause rebuild Cx/ux resume rebuildCx/ux set cache=onoff quiet Cx/ux stop verifyCx/ux flush Cx/ux set autoverify=onoffSupported RAID Types for Caching Cx/ux set identify=onoffCx/ux set ignoreECC=onoff Cx/ux set storsave=protectbalanceperform quiet Cx/ux set name=stringCx/ux set qpolicy=onoff Example 3ware Serial ATA RAID Controller CLI Guide Valid Migration Paths Supported Stripe Sizes Example of capacity expansion Migration ProcessExample of splitting a mirror Example of migrate output Cx/px show Port Object CommandsCx/px show firmware Cx/px show statusCx/px show model Cx/px show serialCx/px show smart Cx/px show ncqCx/px show lspeed Cx/px show capacityCx/px show all Cx/px set identify=onoff Cx/px remove noscan quietCx/bbu show BBU Object CommandsCx/bbu show status Cx/bbu show attribute attributeCx/bbu show temp Cx/bbu show batinstCx/bbu show lasttest Cx/bbu show voltCx/bbu show pcb Cx/bbu show bootloaderCx/bbu show serial Cx/bbu show fwCx/bbu test quiet Cx/bbu enableCx/bbu disable quiet Ex show Enclosure Object CommandsEx show controllers Ex show attribute attributeEx show all Ex show slotsEx show fans Ex show tempEx/slotx set identify=onoff Ex/slotx showEx/slotx show identify Ex/tempx show Help CommandsHelp with specific commands Ex/fanx showAttribute attribute Help Help with attributesHelp rescan Help updateHelp show Help flushHelp /cx/px Help focusHelp /cx Help /cx/uxHelp /ex/tempx Command LoggingReturn Code Help /ex/fanxIf you type