AMCC 9550SX, 9500S Cx/px show status, Cx/px show model, Cx/px show serial, Cx/px show firmware

Page 84

Chapter 2. CLI Syntax Reference

/cx/px show status

This command displays the status of the drive attached to the specified port. (Definitions of the drive statuses are available in the 3ware Serial ATA RAID Controller User Guide.)

Example:

//localhost> /c0/p5 show status /c0/p5 Status = OK

/cx/px show model

This command displays the model of the drive attached to the specified port.

Example:

//localhost> /c0/p5 show model /c0/p5 Model = WDC WD1600BB-00DAA0

/cx/px show serial

This command displays the serial number of the drive attached to the specified port.

Example:

//localhost> /c0/p5 show serial /c0/p5 Serial = WD-WMACK140649

/cx/px show firmware

This command displays the firmware version of the drive attached to the specified port.

Example:

//localhost> /c0/p5 show firmware /c0/p5 Firmware Version = 65.13G65

/cx/px show identify

This command applies only to 9550SX, 9590SE, and 9650SE model controllers that have chassis control hardware (enclosure services) attached.

This command shows whether the LED of the drive attached to the specified port is set to on or off. For details, see “/cx/px set identify=onoff” on page 81.

Example:

//localhost> /c0/p5 show identify /c0/p5 Identify Status = on

78

3ware Serial ATA RAID Controller CLI Guide

Image 84
Contents Command Line Interface 3ware Serial ATA RAID ControllerCopyright Table of Contents 3ware Serial ATA RAID Controller CLI Guide Cx/ux set autoverify=onoff 3ware Serial ATA RAID Controller CLI Guide About this CLI Guide Introduction to the 3ware Command Line Interface Features of the CLISupported Operating Systems TerminologyInstalling the 3ware CLI Installing the 3ware CLI on WindowsTo install 3ware CLI on Windows Permissions Required to Run CLIInstalling the 3ware CLI on Linux and FreeBSD To start CLI, do one of the followingUsing the command interface interactively Working with 3ware CLITo use the CLI interactively Using a single command with output Using an input file to execute a scriptScripting example Outputting the CLI to a Text File ConventionsUnderstanding RAID Levels and Concepts RAID ConceptsAvailable RAID Configurations RAIDRAID 1 Configuration Example RAID 5 Configuration Example RAID 6 Configuration Example RAID 10 Configuration Example Single Disk JbodRAID Configuration Types Possible Configurations Based on Number of DrivesDetermining What RAID Level to Use Hot SpareUsing Drive Capacity Efficiently Drive CapacitySupport for Over 2 Terabytes Common Tasks Mapped to CLI Commands CLI Syntax ReferenceCLI Syntax Reference Syntax Overview Port TasksC1 add type=raid1 disk=0-1 Shell Object Commands Focus ObjectShow ExampleShow ver Show alarms reverse Show diagShow rebuild Show verify Show selftestFlush RescanCommit Controller Object Commands Cx showCx show Cx show attribute attribute Cx show bios Cx show driverCx show model Cx show firmwareCx show serial Cx show pcbCx show pchip Cx show achipCx show numports Cx show numunitsCx show ctlbus Cx show exportjbodCx show spinup Cx show staggerCx show ondegrade Cx show autocarveCx show carvesize Cx show memoryCx show autorebuild Cx show unitstatusCx show allunitstatus Cx show drivestatusCx show all 3JV3MVTASupported RAID Types Supported Stripe Sizes KB Supported Model-Unit Types for ignoreECC Cx rescan noscan Cx commit Cx flushCx show alarms reverse Cx show diag Cx show rebuildRAID-5 Initializing Cx show verify Cx show selftest Setting Up a Rebuild Schedule Cx add rebuild=dddhhdurationSetting Up a Verify Schedule Cx add verify=dddhhdurationSetting Up a Selftest Schedule Cx add selftest=dddhhCx set rebuild=enabledisable1..5 Cx del rebuild=slotidCx del verify=slotid Cx del selftest=slotidCx set verify=enabledisable1..5 Cx set selftest=enabledisable task=UDMASMARTCx set exportjbod=onoff Cx set ondegrade=cacheofffollowCx set spinup=nn Cx set stagger=nn Cx set autocarve=onoffCx set carvesize=1024..2048 Cx set autorebuild=onoff Cx set autodetect=onoff disk=p-pallCx start mediascan Unit Object Commands Cx stop mediascanCx/ux show Cx/ux show status Cx/ux show rebuildstatusCx/ux show verifystatus Cx/ux show initializestatus Cx/ux show nameCx/ux show serial Cx/ux show qpolicyCx/ux show storsave Cx/ux show identifyCx/ux show autoverify Cx/ux show cacheCx/ux show volumes Cx/ux show ignoreECCCx/ux show all Cx/ux remove noscan quiet Cx/ux del noscan quiet Cx/ux start rebuild disk=pp-p...ignoreECCCx/ux start verify Cx/ux pause rebuildCx/ux resume rebuild Supported RAID Logical Unit Types for VerificationCx/ux stop verify Cx/ux flushCx/ux set autoverify=onoff Cx/ux set cache=onoff quietCx/ux set identify=onoff Cx/ux set ignoreECC=onoffSupported RAID Types for Caching Cx/ux set name=string Cx/ux set qpolicy=onoffCx/ux set storsave=protectbalanceperform quiet Example 3ware Serial ATA RAID Controller CLI Guide Valid Migration Paths Supported Stripe Sizes Migration Process Example of splitting a mirror Example of capacity expansion Example of migrate output Port Object Commands Cx/px showCx/px show status Cx/px show modelCx/px show serial Cx/px show firmwareCx/px show ncq Cx/px show lspeedCx/px show capacity Cx/px show smartCx/px show all Cx/px remove noscan quiet Cx/px set identify=onoffBBU Object Commands Cx/bbu showCx/bbu show attribute attribute Cx/bbu show statusCx/bbu show batinst Cx/bbu show lasttestCx/bbu show volt Cx/bbu show tempCx/bbu show bootloader Cx/bbu show serialCx/bbu show fw Cx/bbu show pcbCx/bbu enable Cx/bbu disable quietCx/bbu test quiet Enclosure Object Commands Ex showEx show attribute attribute Ex show controllersEx show slots Ex show fansEx show temp Ex show allEx/slotx show Ex/slotx show identifyEx/slotx set identify=onoff Help Commands Help with specific commandsEx/fanx show Ex/tempx showAttribute attribute Help with attributes HelpHelp update Help showHelp flush Help rescanHelp focus Help /cxHelp /cx/ux Help /cx/pxCommand Logging Return CodeHelp /ex/fanx Help /ex/tempxIf you type