Opticon
OPR 2001
Specifications Manual
7.3.3.Tilt Angle
Scanning performance is guaranteed when γ ≤ ±20°
Figure 6: Tilt angle
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
Distance:
Label:
Angles:
Curvature:
70 mm from the front edge of the scanner
Pitch, Skew Angle, Dead Zone
PCS = 0.9, Resolution = 0.25 mm, Symbology =
Tilt Angle
PCS = 0.9, Resolution = 0.26 mm, Symbology =
Pitch angle: Skew angle: β = +15°, Tilt angle: γ = 0°
Tilt angle: Pitch angle: α = 0°, Skew angle: β = +15°
Skew angle, Dead zone: Pitch angle: α = 0°, Tilt angle: γ = 0°
R = ∞
16