Opticon
OPR 2001
Specifications Manual
13.Durability
13.1.Electrical Noise
No malfunction occurred when sinusoidal electrical noise (10Hz
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS: | 0.9 |
Resolution: | 0.25 mm |
Symbology: | |
Quiet Zone: | 10 mm |
N/W Ratio: | 1:2.5 |
Distance: | 90 mm |
Angle: | α = 0° β = 15° γ = 0° |
Curvature: | R = ∞ |
Power Supply Voltage: | 5.0 V |
13.2.Shock
13.2.1.Drop Test (without packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor three times on each of 5 sides.
Figure 26: Drop test
13.2.2.Drop Test (with individual packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor on each of one corner, three edges, and six sides (10 drop tests in total).
35