14. Reliability

MTBF (Mean Time Between Failures) of this product is 10,000 hours.

The estimate of MTBF is based on standard operation of the product within the recommended temperature range and without extreme electronic or mechanical shock.

15. Auto Trigger (Option)

The product has an optional auto trigger setting, which starts barcode reading automatically by using sensor detection. The scanner starts barcode reading after detecting reflection from the surface when the auto trigger is used.

Auto trigger distance: 50 ±10 mm from the edge of the scanner.

Conditions

Moving Speed:

100 ±10 mm/s (the moving direction is not specified)

 

 

Angle:

Skew angle, excluding Pitch Angle and Dead Zone, specified

 

in section 7.3 Pitch, Skew and Tilt.

Environmental Temperature and

Room temperature and humidity

Humidity:

 

 

 

Environmental Illuminance:

500 to 900 lx

 

 

Conditions for the auto trigger:

1. Barcode sheet: OPTOELECTRONICS Test Sheet (white)

 

Background: OPTOELECTRONICS Test Sheet (black)

 

2. Barcode sheet: OPTOELECTRONICS Test Sheet (black)

 

Background: OPTOELECTRONICS Test Sheet (white)

 

 

Figure 28: Auto trigger operation

37

Image 37
Contents OPR Warranty Limited Warranty and DisclaimersDocument History Copyright 2007 Opticon. All rights reservedContents Cable and Connector Table of Figures Serial number diagram Overview AbstractEnvironmental Specifications Physical FeaturesConditions Ambient Light ImmunityParameter Symbol Min Typ Max Unit Electrical SpecificationsRS-232C USB, WedgeLaser Scanning Specifications Optical SpecificationsParameter Specification Laser Scanning Standard Laser Scanning TiltPrint Contrast Signal PCS Technical SpecificationsResolution Symbology Scan Area and ResolutionQuiet Zone Digits Depth of Field mmPitch Pitch, Skew, and Tilt Pitch AngleSkew angle and dead zone Skew Angle and Dead ZonePitch, Skew Angle, Dead Zone Tilt AngleCurvature CurvatureRS-232C Interface Settings and Communication Interface SpecificationsSignal Level U2 settingPin Assignment Signal PinInterface Circuit Character Format Handshaking Menu/CommandCommunication Format HandshakingBUSY/READY Flow Control Time Out Menu/CommandModem CTS, TXD signal timingACK/NAK ACK/NAK Timeout Menu/CommandACK/NAK-No response ACK/NAK no ResponseConnectors USB Interface Specifications SettingsUSB a connector USB-HIDDesktop PC When using external keyboard DOS/V Wedge Interface Specification SettingsDOS/V Keyboard Connector DOS/V Host ConnectorContact Number Signal Name RS-232C Cable Cable and ConnectorUSB Cable Wedge Cable Connector Specification Scanner SidePin No RS-232C WedgeRS-232C Default Default SettingsUSB-HID Default Wedge Default with external keyboardWedge Default without external keyboard Default Settings 1 Readable CodesSymbology Read Transmit Set Others CodeSymbology Read Transmit Calculate Set Others Code Default Setting Default Settings 2 Read Options, Trigger, BuzzerIndividual Packaging Specification Packaging SpecificationsCollective Packaging Specification Serial NumberElectrical Noise DurabilityShock Drop Test without packaging Drop Test with individual packagingStatic Electricity Vibration StrengthDust and Drip Proof Cable Strength Cable Pulling TestAuto Trigger Option ReliabilityTrigger options Auto Trigger Settings Stand OnlyManually AlwaysProduct Safety Laser SafetyRegulatory Compliance EMCTemperature Conditions SafetyShock Foreign MaterialsMechanical drawing Mechanical Drawing