Opticon
OPR 2001
Specifications Manual
10.3. Default Settings 2: Read Options, Trigger, Buzzer
Item | Default Setting | |
|
|
|
Setting the number of characters | Fixed length OFF all codes | |
|
|
|
Read mode | Single read | |
|
|
|
Multiple read reset time | 500 ms | |
|
|
|
500 ms | ||
|
|
|
Multiple columns read | Disabled | |
|
|
|
| Default option | Read 1 times, redundancy = 0 |
| ([X0] setting) |
|
|
|
|
| Other options | Read n times, redundancy = n+1 |
| ([X1 .. X3] setting) | for following symbologies and lengths: |
| ([BS .. BW] setting) | ● Code39 with length <= 5 |
Redundancy |
| ● MSI/Plessey with length <= 4 |
| ● IATA,Industrial 2of5, Interleaved 2of5 | |
|
| with length <= 8 |
|
| ● Matrix 2of5 (& Chin.Post), Scode |
|
| with length <= 8 |
|
| ● Codabar (NW7) with all lengths |
|
| ● |
|
|
|
Trigger switch | Enabled | |
|
| |
Trigger repeat | Disable trigger repeat | |
|
| |
Auto trigger | Disable auto trigger | |
|
| |
Margin check | Margin check normal | |
|
| |
Buzzer duration | 50 ms | |
|
| |
Buzzer tone | 3 kHz (single tone) | |
|
| |
Buzzer loudness | Loud (Maximum) | |
|
| |
Buzzer timing | Buzzer before transmission | |
|
| |
Startup buzzer | Enable startup buzzer | |
|
| |
Indicator duration | 200 ms | |
|
|
|
33