Opticon
OPR 2001
Specifications Manual
13.3.Vibration Strength
No malfunction occurred after the following vibration test.
Vibration Test: Increase the frequency of the vibration from 10 Hz to 100 Hz with accelerated velocity 19.6m/s2 (2G) for 60 minutes in
13.4.Static Electricity
Air discharge: | 10 kV Max. (No malfunction) |
| 15 kV Max. (No destruction) |
Measurement environment: | Use electrostatic testing device compliant with IEC |
Discharge resistance: | 330 Ω |
Capacitor charging: | 150 pF |
13.5.Dust and Drip Proof
IEC IP42
13.6.Cable Strength
13.6.1.Cable Pulling Test
No malfunction occurred after the following pulling test.
Pulling test: Fix the scanner and pull the cable with the force of 2.5 kg (24.5N) for 1 second. Repeat 20 times.
13.6.2.Cable Tail Bending Test
No malfunction occurred after the following bending test.
Bending test: Fix the scanner and attach a weight of 500 grams (4.9N); swing the cable back and forth at an angle of 90°. Repeat it 1,000,000 times.
Figure 27: Cable tail bending test
36