Primary Features and Pages of the Browser Interface:

Navigation Column: Each page features a navigation column that runs along the left-hand side of the page. The model number of the radio is listed at the top of the navigation column. On the bottom of the navigation column is the current status of the radio including its Base ID, current Opmode, channel, antenna selection, and frequency.

The navigation column also features links to each of the following pages:

System Information: This page shows most of the basic configuration parameters of the radio. It is the first page shown after login.

Configuration: The essential parameters, such as Base ID, IP, Subnet, gateway, channel, and antenna polarization, are set here.

Advanced Setup: The advanced RF parameters, such as transmit power, receiver threshold control, and channel center frequencies, are set here.

Site Survey: With Opmode “Off” the user can conduct a spectrum analysis using this page.

Subscriber Database: This is the page for defining which SUs can associate to the AP.

Link Control: This page shows which SUs are associated. This page also provides several tools for evaluating the quality of the wireless link.

Command Console: From this page, the user can run any console command that is not interactive (i.e. ipconfig) or time sensitive (su linktest). For a complete list of console commands, type "help" or “?” in the entry field.

Logout: This link will end the current browser session with the radio.

Help: The Browser Interface features useful Help pages that explain all listed parameters. To access the Help pages click on the Help link.

Command Line Interface

Although most radio functions can be managed via the browser interface, the command line interface (CLI) provides slightly more functionality, and is usually the management tool of choice for experienced users. The CLI can be accessed through Telnet.

Telnet

Open a command prompt (DOS) session on your PC. Open a Telnet session by typing:

telnet [ip address of radio]

All Trango radios are pre-configured at the factory with a default IP address of 192.168.100.100. The factory default password is trango. Once you connect to the radio you will be greeted with the current hardware and firmware information and prompted for a password. Type in the read-write (RW) password and press enter.

Example:

C:>telnet 192.168.100.100

Welcome to Trango Broadband Wireless M900S-AP 1p0H8005D04030101 Password:

#>

To terminate a CLI session (Telnet or Serial) type the command logout.

Note: Type help or ? for a listing of all the CLI commands. Type help <command>, for the syntax of a particular command.

Trango Broadband Wireless — User Manual M900S Rev. C

Page 8

Image 12
Contents M900S MHz Wireless Broadband System Table of Contents Table of Figures Warranty Information Firmware Notifications PrefaceFCC Information CanadaIntroduction OverviewAuto-retransmit Feature ARQ SmartPolling & Bandwidth ThrottlingHardware Overview M900S AP and SU Hardware ComponentsConnections and Power Getting StartedRadio Management Concepts CAT-5Switch Settings Browser InterfaceBrowser Interface Login Web Browser System InformationCommand Line Interface Telnet ip address of radioTroubleshooting Basic Configuration via Browser Interface Configuring the AP’s Subscriber Unit Database SudbThis section you will Creating an SU in the SU Database Configure Other Basic AP Parameters Default OpmodeIP Address, Subnet Mask, Gateway Active Channel/PolarizationBasic Configuration via Browser Interface Configure Basic SU Parameters SU Basic SetupLED Summary LED SummaryRF Link Loopback Test Link ControlAdvanced Setup SU Ranging TestOther Key Parameters Site Survey Basic Configuration via CLI Access Point Basic SettingsAP Parameter Description Related CLI Command Set baseid baseidSet defaultopmode on or off Set defaultopmode on time secIpconfig new ip new subnet mask new Set apid apid 00-FF in HEXPower set minmaxdBm Sw 0 onoff default is onOn/off command Sw 3 onoff default is offSubscriber Unit Database Sudb Settings Sw 7 onoff default is onRemarks remarks Sudb add suid prreg device id suid SU IDSubscriber Unit Basic Settings Basic Configuration via CLI SU Parameter Description Related CLI Command Set defaultopmode on or offIpconfig new ip new subnet mask new Set baseid baseidAntenna h v e Sw 0 onoffSw 1 onoff Sw 2 onoffM900S Mounting Hardware Assembly Mounting HardwareAlternative Mounting Cabling and Grounding Considerations Standard Mounting Alternative MountingInstallation Notes Command survey time antenna DeploymentSite Selection AP Search and SU Antenna Alignment Example\Rssi Command for Antenna Alignment SU Alignment Using LEDsAP Search Link Management Commands Collocation and Channel PlanningSu ping su# Su su #Su linktest su# Su testrflink su#ARQ with Selected Repeat and Multirate Feature Radio Management Access Via TCP/IP Su password suid all rw ro new password new passwordManagement SU Management from APLoading Multiple SUs into the Sudb using Dload Command SnmpObjects for Monitoring and Control SU Bandwidth MonitoringAP Bandwidth Monitoring Snmp Setup Appendix a Command Set Reference Command Radio DescriptionCommand Radio Description Access Su ipconfig suid new IP new Command Radio Description Access Appendix B Specifications Radio Transmit SpecificationsReceiver Specifications Ethernet I/O Specifications Data Input/OutputPower Specifications Mechanical and Environmental Specifications GeneralConnectors/Indicators Standard External Power SupplyIntegrated Antenna M900S-SU and M900S-SU-EXT