Trango Broadband M900S Preface, FCC Information, Warranty Information Firmware Notifications

Page 4

Preface

Preface

This manual covers basic configuration and installation of the M900S Wireless Broadband System and applies to the following radio part numbers:

M900S-AP

900 MHz Access Point

M900S-SU

900 MHz Subscriber Unit with integrated antenna and connector for external antenna

M900S-SU-EXT

900 MHz Subscriber Unit with connector for external antenna (no integrated antenna)

FCC Information

This device complies with Part 15 of FCC Rules and Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and radiates radio-frequency energy; if not installed and used in accordance with these instructions, the unit may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in any particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one of more of the following measures:

1)Reorient the antenna.

2)Increase the separation between the affected equipment and the unit.

3)Connect the affected equipment to a power outlet on a different circuit from that which the receiver is connected to.

4)Consult the dealer and/or experienced radio/TV technician for help.

FCC ID: NCYM900S

Canada:

IMPORTANT NOTE: Intentional or unintentional changes or modifications must not be made unless under the express consent of the party responsible for compliance. Any such modifications could void the user’s authority to operate the equipment and will void the manufacturer’s warranty. To comply with FCC RF exposure requirements, the following antenna installation and device operating configurations must be satisfied. The antenna for this unit must be fixed and mounted on an outdoor permanent structure with a separation distance of at least two meters from all persons. Furthermore, it must not be co-located or operated in conjunction with any other antenna or transmitter.

Warranty Information

Radios from Trango Broadband Wireless are warranted from one year from date of purchase. Please see www.trangobroadband.com for a complete description of warranty coverage and limitations.

Firmware Notifications

To receive email notifications regarding firmware upgrades and product announcements, register at http://www.trangobroadband.com/mailinglist/mailingListAdd.aspx

Trango Broadband Wireless — M900S User Manual Rev. C

page iv

Image 4
Contents M900S MHz Wireless Broadband System Table of Contents Table of Figures Warranty Information Firmware Notifications PrefaceFCC Information CanadaIntroduction OverviewAuto-retransmit Feature ARQ SmartPolling & Bandwidth ThrottlingHardware Overview M900S AP and SU Hardware ComponentsConnections and Power Getting StartedRadio Management Concepts CAT-5Switch Settings Browser InterfaceBrowser Interface Login Web Browser System InformationCommand Line Interface Telnet ip address of radioTroubleshooting Configuring the AP’s Subscriber Unit Database Sudb Basic Configuration via Browser InterfaceThis section you will Creating an SU in the SU Database Configure Other Basic AP Parameters Default OpmodeIP Address, Subnet Mask, Gateway Active Channel/PolarizationBasic Configuration via Browser Interface Configure Basic SU Parameters SU Basic SetupLED Summary LED SummaryRF Link Loopback Test Link ControlAdvanced Setup SU Ranging TestOther Key Parameters Site Survey Basic Configuration via CLI Access Point Basic SettingsAP Parameter Description Related CLI Command Set baseid baseidSet defaultopmode on or off Set defaultopmode on time secIpconfig new ip new subnet mask new Set apid apid 00-FF in HEXPower set minmaxdBm Sw 0 onoff default is onOn/off command Sw 3 onoff default is offSubscriber Unit Database Sudb Settings Sw 7 onoff default is onRemarks remarks Sudb add suid prreg device id suid SU IDSubscriber Unit Basic Settings Basic Configuration via CLI SU Parameter Description Related CLI Command Set defaultopmode on or offIpconfig new ip new subnet mask new Set baseid baseidAntenna h v e Sw 0 onoffSw 1 onoff Sw 2 onoffM900S Mounting Hardware Assembly Mounting HardwareAlternative Mounting Cabling and Grounding Considerations Standard Mounting Alternative MountingInstallation Notes Deployment Command survey time antennaSite Selection AP Search and SU Antenna Alignment Example\SU Alignment Using LEDs Rssi Command for Antenna AlignmentAP Search Link Management Commands Collocation and Channel PlanningSu ping su# Su su #Su linktest su# Su testrflink su#ARQ with Selected Repeat and Multirate Feature Radio Management Access Via TCP/IP Su password suid all rw ro new password new passwordManagement SU Management from APLoading Multiple SUs into the Sudb using Dload Command SnmpSU Bandwidth Monitoring Objects for Monitoring and ControlAP Bandwidth Monitoring Snmp Setup Appendix a Command Set Reference Command Radio DescriptionCommand Radio Description Access Su ipconfig suid new IP new Command Radio Description Access Appendix B Specifications Radio Transmit SpecificationsReceiver Specifications Ethernet I/O Specifications Data Input/OutputPower Specifications Mechanical and Environmental Specifications GeneralConnectors/Indicators Standard External Power SupplyIntegrated Antenna M900S-SU and M900S-SU-EXT