Trango Broadband M900S Power Specifications, Mechanical and Environmental Specifications General

Page 52

Auto-Negotiation:

Fully supports IEEE802.3-2002 Sect. 2 Clause 28

Bridging Frame Size:

60 to 1600 bytes

Mngmt Frames:

60 to 1472 bytes (includes PING, TELNET, TFTP, HTTP)

Protection:

Bi-directional transient voltage protection diodes on all data lines

 

compliance with:

 

IEC61000-4-2

(ESD)

 

IEC61000-4-4

(EFT)

 

IEC61000-4-5

(Lightning)

Power Specifications

 

 

Input Voltage:

Input voltage range at unit is 10.5 VDC to 24 VDC max

Power is supplied via the unused pins of the RJ-45 Jack. Power is injected into the Ethernet cable using a junction box (provided).

Current Cons.:

400 mA in transmit and receive modes at max power using 24 V

 

 

standard adapter (8 W) and 10 ft cable from J-BOX to unit

 

Protection:

28 volt Transient Voltage Suppression (TVS) on power input

 

 

Note: Voltages above 28 volts will cause damage to unit.

 

Mechanical and Environmental Specifications

 

General

 

 

Material:

High Temp Polycarbonate radome and diecast metal enclosure

 

Size:

12.5” x 8” x 2.75” including mounting studs

 

Weight:

4 lb

 

Mounting:

2 U-Brackets, all-thread rod, nuts and washers

 

Connectors/Indicators

 

 

RF Output:

Integral internal patch antenna per Part 15C, 15.203

 

 

External RP-SMA-f connector for external antenna

 

FCC Compliance:

The transceiver shall comply with the following:

 

 

FCC Part 15.407

 

 

FCC Part 15.207(a)

 

Operating Temp:

-40º to 60º C

 

Storage:

-40º to 85º C

 

Humidity:

100 % (When sealed properly.)

 

NEMA Rating:

NEMA 4

 

Shock:

Sustain 3 axis drop from 5 feet

 

Standard External Power Supply

 

24 Volt DC Power adapter and J-Box supplied with product.

 

Type:

Linear wallmount transformer

 

Input:

120 VAC

 

Output:

24 VDC +/- 1 V

 

Max current:

1000 mA

 

Connector:

5mm DC Barrel-type Plug

 

Standard External Power-over-Ethernet Junction Box

 

Type:

In-line female-to-female RJ-45 adapter for CAT-5 Ethernet cable

 

Connectors:

 

 

Eth. In:

Shielded RJ-45 Jack

 

DC Input:

5mm DC Barrel-type Jack

 

 

 

Trango Broadband Wireless — User Manual M900S Rev. C

Page 48

Image 52
Contents M900S MHz Wireless Broadband System Table of Contents Table of Figures Warranty Information Firmware Notifications PrefaceFCC Information CanadaIntroduction OverviewAuto-retransmit Feature ARQ SmartPolling & Bandwidth ThrottlingHardware Overview M900S AP and SU Hardware ComponentsConnections and Power Getting StartedRadio Management Concepts CAT-5Switch Settings Browser InterfaceBrowser Interface Login Web Browser System InformationCommand Line Interface Telnet ip address of radioTroubleshooting Configuring the AP’s Subscriber Unit Database Sudb Basic Configuration via Browser InterfaceThis section you will Creating an SU in the SU Database Configure Other Basic AP Parameters Default OpmodeIP Address, Subnet Mask, Gateway Active Channel/PolarizationBasic Configuration via Browser Interface Configure Basic SU Parameters SU Basic SetupLED Summary LED SummaryRF Link Loopback Test Link ControlAdvanced Setup SU Ranging TestOther Key Parameters Site Survey Basic Configuration via CLI Access Point Basic SettingsAP Parameter Description Related CLI Command Set baseid baseidSet defaultopmode on or off Set defaultopmode on time secIpconfig new ip new subnet mask new Set apid apid 00-FF in HEXPower set minmaxdBm Sw 0 onoff default is onOn/off command Sw 3 onoff default is offSubscriber Unit Database Sudb Settings Sw 7 onoff default is onRemarks remarks Sudb add suid prreg device id suid SU IDSubscriber Unit Basic Settings Basic Configuration via CLI SU Parameter Description Related CLI Command Set defaultopmode on or offIpconfig new ip new subnet mask new Set baseid baseidAntenna h v e Sw 0 onoffSw 1 onoff Sw 2 onoffM900S Mounting Hardware Assembly Mounting HardwareAlternative Mounting Cabling and Grounding Considerations Standard Mounting Alternative MountingInstallation Notes Deployment Command survey time antennaSite Selection AP Search and SU Antenna Alignment Example\SU Alignment Using LEDs Rssi Command for Antenna AlignmentAP Search Link Management Commands Collocation and Channel PlanningSu ping su# Su su #Su linktest su# Su testrflink su#ARQ with Selected Repeat and Multirate Feature Radio Management Access Via TCP/IP Su password suid all rw ro new password new passwordManagement SU Management from APLoading Multiple SUs into the Sudb using Dload Command SnmpSU Bandwidth Monitoring Objects for Monitoring and ControlAP Bandwidth Monitoring Snmp Setup Appendix a Command Set Reference Command Radio DescriptionCommand Radio Description Access Su ipconfig suid new IP new Command Radio Description Access Appendix B Specifications Radio Transmit SpecificationsReceiver Specifications Ethernet I/O Specifications Data Input/OutputPower Specifications Mechanical and Environmental Specifications GeneralConnectors/Indicators Standard External Power SupplyIntegrated Antenna M900S-SU and M900S-SU-EXT