Fully supports | ||
Bridging Frame Size: | 60 to 1600 bytes | |
Mngmt Frames: | 60 to 1472 bytes (includes PING, TELNET, TFTP, HTTP) | |
Protection: | ||
| compliance with: | |
| (ESD) | |
| (EFT) | |
| (Lightning) | |
Power Specifications |
|
|
Input Voltage: | Input voltage range at unit is 10.5 VDC to 24 VDC max |
Power is supplied via the unused pins of the
Current Cons.: | 400 mA in transmit and receive modes at max power using 24 V |
|
| standard adapter (8 W) and 10 ft cable from |
|
Protection: | 28 volt Transient Voltage Suppression (TVS) on power input |
|
| Note: Voltages above 28 volts will cause damage to unit. |
|
Mechanical and Environmental Specifications |
| |
General |
|
|
Material: | High Temp Polycarbonate radome and diecast metal enclosure |
|
Size: | 12.5” x 8” x 2.75” including mounting studs |
|
Weight: | 4 lb |
|
Mounting: | 2 |
|
Connectors/Indicators |
|
|
RF Output: | Integral internal patch antenna per Part 15C, 15.203 |
|
| External |
|
FCC Compliance: | The transceiver shall comply with the following: |
|
| FCC Part 15.407 |
|
| FCC Part 15.207(a) |
|
Operating Temp: |
| |
Storage: |
| |
Humidity: | 100 % (When sealed properly.) |
|
NEMA Rating: | NEMA 4 |
|
Shock: | Sustain 3 axis drop from 5 feet |
|
Standard External Power Supply |
| |
24 Volt DC Power adapter and |
| |
Type: | Linear wallmount transformer |
|
Input: | 120 VAC |
|
Output: | 24 VDC +/- 1 V |
|
Max current: | 1000 mA |
|
Connector: | 5mm DC |
|
Standard External |
| |
Type: |
| |
Connectors: |
|
|
Eth. In: | Shielded |
|
DC Input: | 5mm DC |
|
|
| |
Trango Broadband Wireless — User Manual M900S Rev. C | Page 48 |