Appendix A Technical Specifications
Compliance Information
Table | Electromagnetic Emissions Requirements (continued) |
| |
|
|
|
|
Country |
| Standard Requirements | Class: Up to 1 GHz |
|
|
|
|
ETSI |
| EN | B |
|
|
| (Noncentral office) |
|
|
|
|
1. Up to 40 GHz
Table | Immunity Tests |
| |
|
|
| |
Test Type or Specification | Applies to | Class/Level/Criteria | |
|
|
| |
Electrostatic Discharge | System/enclosure | Level 4/8KV contact, 15KV air/B | |
|
| ||
|
|
| |
Radiated Immunity | System/enclosure | Level 3/10V/m/A | |
| 1KHz 80% AM | ||
ENV50140:1993 |
| (80MHz - 1 GHz) | |
|
|
|
|
Fast Transients |
| AC power lines | Level 4/4KV 2.5 kHz Rep Freq/B |
DC lines | Level 4/4KV 2.5 kHz Rep Freq/B | ||
|
| ||
|
| Signal lines | Level 4/1KV 5kHz Rep Freq/A |
|
|
| Level 4/2 KV 5kHz Rep Freq/B |
|
|
|
|
Surge Immunity |
| AC power line | Class 4/2KV/B |
2 ohms |
| ||
|
| AC power line | Class 4/4KV/B |
|
| 12 ohms | |
|
|
| |
|
| DC power line | Class 4/500V/B |
|
| DC Power line | Class 4/500V/B |
|
|
| |
|
| Signal lines 2 ohms | Indoor: 500V |
|
|
| |
|
|
| Outdoor: 4KV/R |
|
|
|
|
| Cisco XR 12404 Router Installation Guide |
|