Chapter 4 Troubleshooting the Installation
|
|
| Troubleshooting an AC Power Subsystem |
|
Table | ||||
Table | ||||
|
|
|
|
|
LED Label |
| Color | Function | |
|
|
|
|
|
OUTPUT OK |
| Green | PEM is operating normally in a | |
|
|
| condition. | |
|
|
|
|
|
INPUT OK |
| Green | DC power is present at the PEM input and | |
|
|
| within the specified limits. | |
|
|
|
|
|
OUTPUT FAIL |
| Amber | Indicates a failure in the PEM. | |
|
|
|
|
|
The following conditions must exist for an AC PEM to operate normally:
•The PEM is fully seated in its bay and the ejector levers are secured.
•
•The power switch on the PEM is switched on.
•The green LEDs labeled OUTPUT OK and INPUT OK on the PEM are on.
To help isolate a problem with an
Step 1 If the OUTPUT OK LED is off, verify that the power supply is fully seated in its bay, the ejector levers are flush with the power supply faceplate, and the captive screws are secured.
•If the OUTPUT OK LED is on, go to Step 6.
•If the OUTPUT OK LED remains off, go to Step 2
Step 2 Check the AC power source.
•Check the AC power cord from the power source to the router.
–Verify that the power cord is seated securely in the PDU and the AC outlet.
–Verify that the power cord is not worn or damaged. If the insulation appears cracked or broken, or the plugs appear loose, replace the power cord with a new power cord.
•Verify that the AC power source circuit breaker is on and has not tripped, and that the circuit breaker has the proper current rating.
|
| Cisco XR 12404 Router Installation Guide |
|
|
|
|
| ||
|
|
| ||
|
|
|