Socket Mobile GFK0121E manual Index-2

Page 62

Index

for analog, RTD, or Thermocouple block, 5-10

Different Baud error, 7-2

Different Block Types error, 7-2

Dimensions, 1-5

Display, 1-5

special characters, 1-3testing, 3-7

Duplicate Block Number error, 7-2

Duplicate I/O References error, 7-2

E

EEPROM failure, 3-7

EEPROM Failure error, 7-2

Error messages, during HHM test, 3-7

F

Failed switch diagnostic, 5-9

Fault clearing

configuring HHM to enable fault clear- ing, 3-6

from Block/Bus Status screen, 5-3on analog, RTD, or Thermocouple

block, 5-10

on discrete, relay or High-speed Count- er block, 5-9

on remote drop, 5-14 , 5-16

Features, 1-1

Feedback Error diagnostic, 5-10

Field Control products, compatibility with HHM versions, 1-4

Field Processor, configuration overview, 4-7

ForcingI/O

configuring HHM to perform, 3-6on analog, RTD, or Thermocouple

block, 5-10

on Monitor/Control Reference screen, 5-9

on remote drop, 5-14 , 5-15viewing present status, 5-4

viewing present status of analog circuit, 5-5

viewing present status of circuit on RTD or Thermocouple block, 5-5

Function Disabled error, 7-2

G

Genius blocks

compatibility with HHM versions, 1-4I/O type, 5-4

monitoring with HHM, 5-4

H

Hardware setup, 2-1

High-speed Counter blocks, Monitor block screen, 5-6

High-speed Counter Block Inputs, display, 5-6presets, display, 5-6

Humidity, 1-5

I

I/O forced status, 5-4

I/O scanning, for Field Processor, disable, 4-8

I/O type, 5-4

Input Shorted diagnostic, 5-10

Installation, instructions, 2-6 , 2-7

Installed HHM, configuration sugges- tions, 2-6

Internal Fault diagnostic, 5-10

Invalid Block Configuration error, 7-2

K

Key=Monitor error, 7-2

Keypad, 1-1 , 1-2testing operation, 3-7

Keys, 1-3 , 1-5

Keyswitch, 1-1positions, 1-3

L

Languages, 1-1 , 1-5 , 3-5

Index-2

GFK-0121E

Image 62
Contents GE Fanuc Automation GFL±002 Content of this Manual Related PublicationsPreface Contents Chapter Introduction Hand-held Monitor Description HHM KeypadHHM Display KeyswitchAccessories HHM Compatibility HHM Specifications Optional AccessoriesCharging the Battery Pack for AC Operation Selecting 120 VAC or 230 VACUsing the 230VAC Power Adapter InstructionsCharging the Battery Pack Battery OperationLow Battery Power Replacing the Battery PackChanging the Prom Conductive mat Permanent Installation Configuring a Permanently-installed HHMHHM Installation Instructions CutoutInstalling the D-Shell HHM Connector SERInstalling a Separate Hand-held Monitor Connector Mounting the HHM ConnectorMaking the Bus Connections Chapter Getting Started Setting the HHM Baud Rate Powerup Error MessagesDisplaying the Home Menu Main HHM ScreensConfiguring the Hand-held Monitor Changing the HHM Device NumberEnabling/Disabling Automatic Shutoff Changing the HHM Display LanguageSelecting the Host CPU Enabling/Disabling the Ability to Clear Faults Enabling/Disabling the Ability to Force I/O CircuitsTesting the Keypad Testing Operation of the Hand-held MonitorTesting the Internal Electronics Testing the Display ScreenChapter Device Configuration Overview Online Configuration Online or Offline ConfigurationStarting Configuration Offline ConfigurationDisplaying the Configuration Menus Completing the Program Block ID Screens To Set the I/O Map for a Remote I/O ScannerConfiguration Notes Configuring the Remote DropConfiguring Block Features ConfiguringGenius BlocksCopying a Configuration Configuration InstructionsSelect a PLC Reference Address Configure Additional FeaturesChange the Bus Address Configure Data Addresses and Lengths Configuring Individual Field Control ModulesDisable the I/O Scan Assign I/O References for the Module Configuring Module FeaturesAdd Modules and Assign References Chapter Monitoring the Bus and its Devices Displaying Information About Bus Devices Selecting Another DeviceSwitching a Dual Bus Monitoring the Bus StatusMaking the Block Active Monitoring a Genius BlockMonitor Block Display for Discrete I/O and Input Blocks Block ReferencesMonitor Block Display for Discrete Relay OutputBlocks Monitor Block Display for Analog BlocksPreset Outputs Monitor Block Display for a High-speed Counter BlockMonitor Block Display for a PowerTRACBlock Calculated DataBasic Monitor/Control Display Format Forcing an Input or Output DiagnosticsClearing Circuit Faults Forcing an Analog, RTD, or Thermocouple Value Selecting a Memory Type or Address Monitor/Control Reference Displays for a PowerTRAC BlockPowerTRAC Data Sequence PowerTRAC Extra Calculated Data Lpio Screens PowerTRAC Status Inputs ScreensPowerTRAC Calculated Data Screens PowerTRAC Control Outputs ScreensMonitoring/Controlling Remote Drop Data Displaying Other CircuitsForcing a Circuit Displaying and Clearing Remote Drop FaultsClearing Faults Displaying Another Reference Changing the Display ModeMonitoring/Controlling Field Control Data Returning to the Previous MenuDisplaying Field Control Faults Clearing Field Control FaultsPulse Test Error Messages Pulse Testing Outputs on Discrete Genius BlocksClearing Pulse Test Faults Executing a Pulse TestChapter Reading CPU Memory General InstructionsSeries 90 PLC Enter or Change the Memory Location Series Six PLCEnter or Change the PLC Type Series Five PLC DataChanging the Data Format Changing the Selected AddressChapter Error Messages Powerup Error MessagesOperating Error Messages Configuration Error MessagesIndex Index-2 Index-3 Index-4