Socket Mobile GFK0121E manual Changing the Prom

Page 14

2

Changing the PROM

New features can be added to upgrade a Hand-held Monitor by replacing its PROM as described below.

Caution

To prevent possible damage to the Hand-held Monitor, this operation should be performed in an area equipped with suitable electrostatic discharge protection.

1.If the HHM is connected to AC power, disconnect it.

2.Remove the HHM battery pack as described on the previous page.

3.On the front of the Hand-held Monitor, remove the two Phillips-head screws located near the 7 and HOME keys.

4.Gently raise the keyboard up from the bottom to release the lip between the keyboard and the display.

5.Once this lip is free, open the keyboard to the right, as illustrated below. It is not necessary to remove the ribbon connector.

Install PROM with notch to right as shown

GENIUS

mon

 

Hand Held Monitor

 

 

cfg

GE Fanuc

 

6.Remove the old PROM. If you don't have a PROM extraction tool, a small screwdriv- er can be used instead, carefully working from side to side.

2-4

Hand-held Monitor User's Guide ± June 1994

GFK-0121E

Image 14
Contents GE Fanuc Automation GFL±002 Content of this Manual Related PublicationsPreface Contents Chapter Introduction Hand-held Monitor Description HHM KeypadHHM Display KeyswitchAccessories HHM Compatibility HHM Specifications Optional AccessoriesCharging the Battery Pack for AC Operation Selecting 120 VAC or 230 VACUsing the 230VAC Power Adapter InstructionsCharging the Battery Pack Battery OperationLow Battery Power Replacing the Battery PackChanging the Prom Conductive mat Permanent Installation Configuring a Permanently-installed HHMHHM Installation Instructions CutoutInstalling the D-Shell HHM Connector SERInstalling a Separate Hand-held Monitor Connector Mounting the HHM ConnectorMaking the Bus Connections Chapter Getting Started Setting the HHM Baud Rate Powerup Error MessagesDisplaying the Home Menu Main HHM ScreensConfiguring the Hand-held Monitor Changing the HHM Device NumberEnabling/Disabling Automatic Shutoff Changing the HHM Display LanguageSelecting the Host CPU Enabling/Disabling the Ability to Clear Faults Enabling/Disabling the Ability to Force I/O CircuitsTesting the Keypad Testing Operation of the Hand-held MonitorTesting the Internal Electronics Testing the Display ScreenChapter Device Configuration Overview Online Configuration Online or Offline ConfigurationStarting Configuration Offline ConfigurationDisplaying the Configuration Menus Completing the Program Block ID Screens To Set the I/O Map for a Remote I/O ScannerConfiguration Notes Configuring the Remote DropConfiguring Block Features ConfiguringGenius BlocksCopying a Configuration Configuration InstructionsSelect a PLC Reference Address Configure Additional FeaturesChange the Bus Address Configure Data Addresses and Lengths Configuring Individual Field Control ModulesDisable the I/O Scan Assign I/O References for the Module Configuring Module FeaturesAdd Modules and Assign References Chapter Monitoring the Bus and its Devices Displaying Information About Bus Devices Selecting Another DeviceSwitching a Dual Bus Monitoring the Bus StatusMaking the Block Active Monitoring a Genius BlockMonitor Block Display for Discrete I/O and Input Blocks Block ReferencesMonitor Block Display for Discrete Relay OutputBlocks Monitor Block Display for Analog BlocksPreset Outputs Monitor Block Display for a High-speed Counter BlockMonitor Block Display for a PowerTRACBlock Calculated DataBasic Monitor/Control Display Format Forcing an Input or Output DiagnosticsClearing Circuit Faults Forcing an Analog, RTD, or Thermocouple Value Selecting a Memory Type or Address Monitor/Control Reference Displays for a PowerTRAC BlockPowerTRAC Data Sequence PowerTRAC Extra Calculated Data Lpio Screens PowerTRAC Status Inputs ScreensPowerTRAC Calculated Data Screens PowerTRAC Control Outputs ScreensMonitoring/Controlling Remote Drop Data Displaying Other CircuitsForcing a Circuit Displaying and Clearing Remote Drop FaultsClearing Faults Displaying Another Reference Changing the Display ModeMonitoring/Controlling Field Control Data Returning to the Previous MenuDisplaying Field Control Faults Clearing Field Control FaultsPulse Test Error Messages Pulse Testing Outputs on Discrete Genius BlocksClearing Pulse Test Faults Executing a Pulse TestChapter Reading CPU Memory General InstructionsSeries 90 PLC Enter or Change the Memory Location Series Six PLCEnter or Change the PLC Type Series Five PLC DataChanging the Data Format Changing the Selected AddressChapter Error Messages Powerup Error MessagesOperating Error Messages Configuration Error MessagesIndex Index-2 Index-3 Index-4