Rotel RB-1070 Placement, AC Power Input, Power Switch and Power Indicator, Protection Circuitry

Page 6

RB-1070Stereo Power Amplifier

Placement

The RB-1070 generates heat as part of its nor- mal operation. The heat sinks and ventilation openings in the amplifier are designed to dissipate this heat. The ventilation slots in the top cover must be open. There should be 10 cm (4 inches) of clearance around the chas- sis, and reasonable airflow through the in- stallation location, to prevent the amplifier from overheating.

Likewise, remember the weight of the ampli- fier when you select an installation location. Make sure that the shelf or cabinet can sup- port its considerable bulk. Again, use com- mon sense.

AC Power and Control

AC Power Input

Because of its high power rating, the RB-1070 can draw considerable current. Therefore, it should be plugged directly into a 2-pin po- larized wall outlet. Do not use an extension cord. A heavy duty multi-tap power outlet strip may be used if it (and the wall outlet) is rated to handle the current demanded by the RB-1070 and all the other components con- nected to it.

Be sure the power switch on the front panel of the RB-1070 is turned off (in the out posi- tion). Then, connect the supplied power cord to the AC power outlet.

Your RB-1070 is configured at the factory for the proper AC line voltage in the country where you purchased it (either 115 volts AC or 230 volts AC with a line frequency of either 50 Hz or 60 Hz). The AC line configuration is noted on a decal on the back panel.

Note: Should you move your RB-1070 amplifier to another country, it is possible to reconfigure your amplifier for use on a different line voltage. Do not attempt to perform this conversion yourself. Opening the enclosure of the RB-1070 exposes you to dangerous voltages. Consult a qualified service person or the Rotel factory service department for information.

6

If you are going to be away from home for an extended period of time such as a month- long vacation, it is a sensible precaution to unplug your amplifier (as well as other au- dio and video components) while you are away.

Power Switch and Power Indicator

The power switch is located on the front panel of your amplifier. To turn the amplifier on, push the switch in. The LED indicator above the switch will light, indicating that the amplifier is turned on. To turn the amplifier off, push the button again and return it to the out po- sition.

Trigger ON/OFF

Mode Selector

The Amplifier provides the option for manual or automatic power on/off operation. These modes are selectable using a toggle switch on the back panel.

With the switch in the +12V TRIGGER ON position, the amplifier is turned on automati- cally when a 12V trigger signal is present at the 3.5 mm Jack of TRIGGER IN on the rear panel. The amplifier will go into standby mode if the +12V signal is not present. The front panel POWER SWITCH overrides this function. It must be ON for the +12V trigger to work. Turning the switch OFF cuts power to the amplifier, regardless of whether or not a trigger signal is present.

12V Trigger Input and Output

The jack labeled IN is for connecting the 3.5mm Plug/Cable carrying a +12 volt trig- ger signal to turn the amplifier on and off. To use this feature the toggle switch must be set to the ON position. This input accepts any control signal (AC or DC) ranging from 3 volts to 30 volts.

The jack labeled OUT is for connecting an- other 3.5mm plug/cable to provide a 12V trigger signal to other components. The 12V output signal is available whenever a +12 volt trigger signal is applied to the IN connector.

Protection Circuitry

The RB-1070 features a thermal protection cir- cuit that protects the amplifier against potential damage in the event of extreme or faulty operating conditions. Unlike many designs, the RB-1070’s protection circuit is indepen- dent of the audio signal and has no impact on sonic performance. Instead, the protection circuit monitors the temperature of the output devices and shuts down the amplifier if tem- peratures exceed safe limits.

Most likely, you will never see this protection circuitry in action. However, should a faulty condition arise, the amplifier will stop play- ing and the LED indicator on the front panel will light up.

If this happens, turn the amplifier off, let it cool down for several minutes, and attempt to iden- tify and correct the problem that caused the protection circuitry to engage. When you turn the amplifier back on, the protection circuit will automatically reset and the indicator LED should go out.

In most cases, the protection circuitry activates because of a fault condition such as shorted speaker wires, or inadequate ventilation lead- ing to an overheating condition. In very rare cases, highly reactive or extremely low im- pedance speaker loads could cause the pro- tection circuit to engage.

If the protection circuitry triggers repeatedly and you are unable to isolate and correct the faulty condition, contact your authorized Rotel dealer for assistance in troubleshooting.

Input Signal Connection

[See Figure 2 for normal stereo wir-

ing illustration.]

The RB-1070 has conventional RCA type in- put connectors, the type found on nearly all audio equipment.

Note: To prevent loud noises that neither you nor your speakers will appreciate, make sure the amplifier is turned off when you make any signal connections.

Select a high quality pair of audio intercon- nect cables. Connect the left channel output of your preamp to the left channel input on the RB-1070. Connect the right channel output of your preamp to the right channel input.

Image 6
Contents RB-1070 RB-1070 Stereo Power Amplifier English Preamplifier Few Precautions About Rotel Getting StartedPower Switch and Power Indicator PlacementAC Power Input Trigger ON/OFF Mode SelectorSpeaker Selection Speaker Wire SelectionResetting Jumpers Polarity and PhasingFuse Replacement TroubleshootingSpecificationsFront Panel Power Indicator Is Not Lit Protection Indicator Is LitUn mot sur Rotel Préliminaire Alimentation et commutateur généralPrises d’entrée Dépannage Raccordement des enceintes en mode stéréoRaccordement des enceintes en mode ponté Raccordement des câbles d’entréeAbsence de son Remplacement du fusibleFiche technique Diodes de protection alluméesNetzeingang Netzschalter Bedienelemente und AnschlüsseEinige Vorsichtsmaßnahmen Aufstellung des Gerätes Trigger ON/OFF SchalterEinige Vorsichtsmaßnahmen Die Firma RotelNetzspannung und Bedienung Aufstellung des GerätesEingänge LautsprecherUmstecken der Jumper Siehe Anschlußdiagramm und Jumperpositionen in AbbildungAnschließen der Lautsprecher bei Stereobetrieb Anschließen eines VorverstärkersAustauschen der Sicherung Bei StörungenDie Betriebsanzeige leuchtet nicht Kein TonIndice Alcune Parole Sulla RotelPer Cominciare Selezione Dei Diffusori Ingresso e uscita del trigger da +12VCircuito di Protezione Scelta Dei CaviRicerca Dei Guasti Caratteristiche Contenido Algunas Precauciones Acerca de RotelPara Empezar ColocaciónMarcha Conmutador e IndicadorLuminoso de Puesta en Circuitería de ProtecciónConexión de las Cajas Acústicas Funcionamiento en Modo Monofónico PuenteadoProblemas y Posibles Soluciones Características Técnicas Inhoud Wij van Rotel Het aansluiten op het lichtnet en de bediening Luidsprekers De luidsprekerverbindingen De lichtnet-indicator werkt nietTechnische gegevens Het vervangen van de zekeringUSA