Rotel RB-1070 TroubleshootingSpecifications, Front Panel Power Indicator Is Not Lit, No Sound

Page 8

RB-1070Stereo Power Amplifier

8

TroubleshootingSpecifications

Most difficulties in audio systems are the re- sult of poor or wrong connections, or improper control settings. If you encounter problems, isolate the area of the difficulty, check the con- trol settings, determine the cause of the fault and make the necessary changes. If you are unable to get sound from the RB-1070, refer to the suggestions for the following conditions:

Front Panel Power Indicator Is Not Lit

No main power to the RB-1070. Check the front panel power switch. Make sure that it is set to the on position. Check AC power con- nections at the amplifier and the AC outlet.

Fuse Replacement

If everything checks out correctly and you still cannot get the amplifier to turn on, the inter- nal power fuse may have blown. If you be- lieve this has happened, contact your autho- rized Rotel dealer for information on where to take your amplifier to get the fuse replaced.

No Sound

If the amp is getting AC power, but is pro- ducing no sound, check the Protection indi- cator on the front panel. If it is lit, see below. If not, check all of your connections and control settings on associated components.

Protection Indicator Is Lit

The front panel indicator lights when the RB-1070 protection circuits have shut off the amplifier. Typically, this occurs only when the ventilation openings are blocked, when there is faulty speaker wiring, or after a period of extreme use. Turn off the system and wait for the amp to cool. Then push the front panel power switch in and out to reset the protec- tion devices. If the problem is not corrected or reoccurs, there is a problem with the sys- tem or the amplifier itself.

Continuous Power Output (20-20 kHz, < 0.03%) Bridged Mono Power Output (20-20 kHz, < 0.1%) Total Harmonic Distortion (20Hz-20kHz, 8 ohms) Intermodulation Distortion (60 Hz : 7 kHz, 4:1) Frequency Response (+0.5 dB, -3 dB)

Damping Factor (20-20,000 Hz, 8 ohms) Speaker Impedance

Signal to Noise Ratio (IHF A network) Input Impedance/Sensitivity Power Requirements

Power Consumption

Dimensions (W x H x D)

Weight (net)

All specifications are accurate at the time of printing.

Rotel reserves the right to make improvements without notice.

130 watts/ch into 8 ohms

330 watts/ch into 4 ohms

<0.03%

<0.03% 4Hz-100kHz 500

4 ohms minimum

120 dB

33 k Ohms/1.0 volt

115 Volts, 60 Hz (U.S. version)

230 Volts, 50 Hz (European version)

400 Watts

430 x 121 x 350 mm

1615/16 x 43/4 x 133/4 in

11.9 kg, 26.25 lb.

Image 8
Contents RB-1070 RB-1070 Stereo Power Amplifier English Preamplifier Few Precautions About Rotel Getting StartedPlacement AC Power InputPower Switch and Power Indicator Trigger ON/OFF Mode SelectorSpeaker Wire Selection Resetting JumpersSpeaker Selection Polarity and PhasingTroubleshootingSpecifications Front Panel Power Indicator Is Not LitFuse Replacement Protection Indicator Is LitUn mot sur Rotel Préliminaire Alimentation et commutateur généralPrises d’entrée Raccordement des enceintes en mode stéréo Raccordement des enceintes en mode pontéDépannage Raccordement des câbles d’entréeRemplacement du fusible Fiche techniqueAbsence de son Diodes de protection alluméesBedienelemente und Anschlüsse Einige Vorsichtsmaßnahmen Aufstellung des GerätesNetzeingang Netzschalter Trigger ON/OFF SchalterDie Firma Rotel Netzspannung und BedienungEinige Vorsichtsmaßnahmen Aufstellung des GerätesEingänge LautsprecherSiehe Anschlußdiagramm und Jumperpositionen in Abbildung Anschließen der Lautsprecher bei StereobetriebUmstecken der Jumper Anschließen eines VorverstärkersBei Störungen Die Betriebsanzeige leuchtet nichtAustauschen der Sicherung Kein TonIndice Alcune Parole Sulla RotelPer Cominciare Ingresso e uscita del trigger da +12V Circuito di ProtezioneSelezione Dei Diffusori Scelta Dei CaviRicerca Dei Guasti Caratteristiche Contenido Acerca de Rotel Para EmpezarAlgunas Precauciones ColocaciónConmutador e Indicador Luminoso de Puesta enMarcha Circuitería de ProtecciónConexión de las Cajas Acústicas Funcionamiento en Modo Monofónico PuenteadoProblemas y Posibles Soluciones Características Técnicas Inhoud Wij van Rotel Het aansluiten op het lichtnet en de bediening Luidsprekers De lichtnet-indicator werkt niet Technische gegevensDe luidsprekerverbindingen Het vervangen van de zekeringUSA