- INSTALLATION MANUAL -
INPUTS/OUTPUTS
Press menu/esc to select the desired menu
Use the keys up and down to display
Inputs/Outputs
Esc
Press enter to gain access to the mode for displaying inputs and outputs The display shows
Use the keys up and down to scroll the data to display
Room 21°F
Probe 59°F
Food 93°F External 90°F
Evap. 14°F
Cond. 70°F
C D FE FC L R A 1 0 0 1 1 0 0
DI1 | DI2 | FAN |
0 | 1 | 80 |
Room: Room air temperature
Probe: Core temperature – see core probe section
Food: under surface probe – see core probe section
External: over surface probe – see core probe section
Evaporator and Condenser temperature values
Outputs state | C | Compressor | R | Door resistance | ||
1 | = relay activated | D | Defrost | A | Alarm | |
FE | Evaporator fan | DI1 | Inputs state micro | |||
0 | = relay | |||||
FC | Condenser fan | DI2 | Inputs state thermostat | |||
Digital inputs state and evaporator | L | Sterilization | FAN | Evaporator fan speed | ||
|
|
|
| |||
fan speed |
|
|
|
|
Press menu/esc to exit
PRINTER INSTALLATION
The printer is not supplied as standard equipment .
Should you purchase the printer, please follow the installation instructions to install.
37