MANUAL CYCLES

ƒNEGATIVE FREEZING CYCLE

WITH CORE PROBE: cycle suitable for freezing foodstuffs using a room temperature of about -22[°F]. The cycle is controlled by the core probe.

WITH TIMER: cycle suitable for freezing foodstuffs using a room temperature of about -22[°F]. The cycle is time-controlled.

ƒSOFT POSITIVE CHILLING CYCLE

WITH CORE PROBE: cycle suitable for cooling foodstuffs with thickness lower than 1.5” using a room temperature of about +32[°F]. The cycle is controlled by the core probe. WITH TIMER: cycle suitable for cooling foodstuffs with thickness lower than 1.5” using a room temperature of about +32[°F]. The cycle is time-controlled.

ƒHARD POSITIVE CHILLING CYCLE

WITH CORE PROBE: cycle suitable for cooling foodstuffs with thickness exceeding 1.5” using a room temperature ranging from -22[°F] to +23[°F]. The cycle is controlled by the core probe. WITH TIMER: cycle suitable for cooling foodstuffs with thickness exceeding 1.5” using a room temperature ranging from -22[°F] to +23[°F]. The cycle is time-controlled.

NOTE: At the end of the chilling or freezing cycle the system will automatically switch to the conservation mode (+36°F at the end of the positive chilling and –8°F at the end of the freezing phase).

During the conservation mode, the condenser fan and compressor remain on and the evaporator fans are set to 50%.

Cooling time

 

FOODSTUFF

 

 

SHEET

 

 

MAX. LOAD

 

 

PRODUCT

 

 

QUICK COOLING

 

 

CYCLE

 

 

 

 

 

 

 

 

THICKNESS

 

 

TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRST COURSES

 

 

 

 

 

 

 

Bechamel

 

GN1/1 h60

 

0.21 cuft

 

1.5”

 

70 minutes

 

HARD POSITIVE

 

Meat broth

 

GN1/1 h110

 

0.28 cuft

 

2.7”

 

110 minutes

 

HARD POSITIVE

 

Cannelloni

 

GN1/1 h40

 

9 lbs

 

1.5”

 

40 minutes

 

HARD POSITIVE

 

Vegetable soup

 

GN1/1 h100

 

0.17 cuft

 

2”

 

100 minutes

 

HARD POSITIVE

 

Fresh pasta

 

GN1/1 h40

 

0.5 lbs

 

2”

 

20 minutes

 

NEGATIVE

 

Meat and tomato sauce

 

GN1/1 h60

 

11 lbs

 

2”

 

90 minutes

 

HARD POSITIVE

 

Bean soup

 

GN1/1 h60

 

11 lbs

 

2”

 

100 minutes

 

HARD POSITIVE

 

Fish soup

 

GN1/1 h60

 

9 lbs

 

2”

 

110 minutes

 

HARD POSITIVE

 

 

 

 

 

 

 

MEAT AND

POULTRY

 

 

 

 

 

 

 

Roast pork

 

GN1/1 h60

 

17.7 lbs

 

4”

 

110 minutes

 

HARD POSITIVE

 

Braised beef

 

GN1/1 h60

 

17.7 lbs

 

6”

 

110 minutes

 

HARD POSITIVE

 

Boiler beef

 

GN1/1 h60

 

13.24 lbs

 

6”

 

110 minutes

 

HARD POSITIVE

 

Chicken breast

 

GN1/1 h40

 

11 lbs

 

2”

 

30 minutes

 

SOFT POSITIVE

 

Roast-beef

 

GN1/1 h40

 

9 lbs

 

4”

 

80 minutes

 

HARD POSITIVE

 

 

 

 

 

 

 

FISH

 

 

 

 

 

 

 

 

 

 

Baked grouper

 

GN1/1 h40

 

6.5 lbs

 

2”

 

110 minutes

 

HARD POSITIVE

 

Squill

 

GN1/1 h40

 

4.4 lbs

 

1.2”

 

25 minutes

 

HARD POSITIVE

 

Vacuum-stored mussel

 

GN1/1 h60

 

4.4 lbs

 

max 2.5”

 

20 minutes

 

HARD POSITIVE

 

Fish salad

 

GN1/1 h40

 

8.8 lbs

 

1.5”

 

30 minutes

 

NEGATIVE

 

Boiled polyp

 

GN1/1 h60

 

11 lbs

-

 

 

60 minutes

 

HARD POSITIVE

 

Stewed cuttlefish

 

GN1/1 h60

 

8.8 lbs

 

2”

 

60 minutes

 

HARD POSITIVE

 

 

 

 

 

 

 

VEGETABLES

 

 

 

 

 

 

 

Carrots trifolate

 

GN1/1 h60

 

8.8 lbs

 

2”

 

60 minutes

 

HARD POSITIVE

 

Mushrooms trifolati

 

GN1/1 h60

 

8.8 lbs

 

2”

 

60 minutes

 

HARD POSITIVE

 

Zucchinis trifolate

 

GN1/1 h60

 

6.6 lbs

 

2”

 

90 minutes

 

HARD POSITIVE

 

 

 

 

 

 

 

PASTRY/DESSERT

 

 

 

 

 

 

 

Vanilla / chocolate pudding

 

GN1/1 h60

 

0.21 cuft

 

2”

 

90 minutes

 

SOFT POSITIVE

 

Creme anglaise

 

GN1/1 h60

 

0.1 cuft

 

2”

 

100 minutes

 

SOFT POSITIVE

 

Custard

 

GN1/1 h60

 

0.1 cuft

 

2”

 

100 minutes

 

SOFT POSITIVE

 

Panna cotta (single portion)

 

GN1/1 h40

 

0.1 cuft

 

2.3”

 

60 minutes

 

SOFT POSITIVE

 

Ice-cream

 

GN1/1 h40

 

6.6 lbs

 

2.3”

 

50 minutes

 

SOFT POSITIVE

 

Tiramisù

 

GN1/1 h60

 

11 lbs

 

2”

 

45 minutes

 

SOFT POSITIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

Image 17
Contents 3185550/146127 Page Description of Controls ………………………………………………………………7 Maintenance and Cleaning ……………………………………………………………23Programs .…………………….………………………………………………………………10 Manual Cycles .…………….………………………………………………………………15Dimensions …………………………………………………………………………………42 Installation …………………………………………………………………………………26Refrigerant Material Safety Data SHEET………………………………………40 Information for the Reader Chapter Technical DataGeneral Instructions on Delivery Chapter General InstructionsTab.2 Model Max. output/cycle Capacity Setting UPPosition of Trays Storage Temperatures and TimesMachine Loading Core Probe Tab.3Description of Controls Control Panel Chapter… Core … Time Manual settingPrograms Manual Store Ok or No IFR Chilling Cycle Operation ChapterPrograms Display shows the program number and name Recommended Working CyclesUSER’S Cycle USER’S ProgramsStoring USER’S Programs Keep menu/esc pressed for 5 seconds. The display Delete a USER’S ProgramShows Rename a USER’S ProgramPRE-COOLING Cycle ƒ Negative Freezing Cycle Manual Cyclesƒ Soft Positive Chilling Cycle ƒ Hard Positive Chilling CyclePress enter to confirm your choice. The display shows Negative Freezing Cycle with TimerNegative Freezing Cycle with Core Probe Soft Positive Chilling Cycle with Core Probe Hard Positive Chilling Cycle with Core Probe Soft Positive Chilling Cycle with TimerHard Positive Chilling Cycle with Timer Negative Store Storing CyclesPositive Store Printing DefrostingPress enter to start printing the saved cycles Maintenance and Cleaning Maintenance ChapterCleaning the Cabinet Pict.12STAINLESS-STEEL Maintenance Cleaning the AIR CondenserDIS USE OFFMAX Room Temperature TAB.4 InstallationIntroduction Detail of above data platePict.27 WiringConnection to Condensate Drain TestingLanguage Clock SettingProgressive number ranging from A01 to A30 Alarms and Fault Analysis TAB.5TAB.5 Fault Cause RemedyDescription of Parameters ServiceParameters Print Display shows Changing ParametersUse the keys up and down to display Reset MemoryThis function restores the original parameters Restoring Default ParametersINPUTS/OUTPUTS Printer InstallationMod. BCF44244 / BCB44244 / BC40-4 Electrical Compartment AccessControl and Safety Systems Wiring Diagram PlateProcedure for Rough Dismantling the Appliance DisposalMount the upper bracket Refrigerant Material Safety Data SheetDoor Reversal Installation Manual BCF11514 BC113-14 DimensionsBCF22020 TAB.1a Model AppendixTAB.4 Description Pict.47Comment SE Préparer AU Démarrage ……………………………………………4 Liste DES Références Normatives …………………………………………………3Entretien DU Tableau Électrique …………………………………………………37 Donnees Generales a LA Remise Chapitre Informations Pour LE Lecteur ChapitreDonnées Générales Données TechniquesTab.2 Modéle Rendu max/cycle Capacité Comment SE Préparer AU DémarrageDurée DE Conservation Placement DES RécipientsChargement DE LA Cellule Sonde a Coeur Description DES Commandes Panneau DE Commande ChapitreRéglages manuels Programmes Manuel Conservation… Coeur … Temps Ok ou No Imprimer Regler Horlose Langue Alarme ServiceDegivrage Cycle DE Refroidissement Rapide IFR Fonctionnement ChapitreProgrammes Utilisation DE Programmes Utilisateur Cycles ConseillésCycle Utilisateur Programme Le premier emplacement libre s’afficheEnregistrement Programmes Utilisateur Renommer UN Programme Utilisateur Effacer UN Programme UtilisateurOn affiche Cycle DE PRÉ-REFROIDISSEMENT Temps de refroidissement rapide Cycles ManuelsCycle DE Refroidissement Rapide Negatif À Temps Cycle DE Refroidissement Rapide Negatif Avec Sonde À CoeurNeg Temps Ok Esc Cycle DE Refroidissement Rapide Positif Soft À Temps Cycle DE Refroidissement Rapide Positif Hard À Temps Conservation Positive Cycle DE ConservationAppuyer sur la touche Up pour afficher Conservation NegativeImpression DégivrageManuel D’INSTRUCTION Nettoyage Enceinte Entretien ChapitreNettoyage ET Entretien Entretien Acier Inox Nettoyage DU Condenseur a AIRInterruption D’UTILISATION Mise EN Place Temperature MAX DU Local D’UTILISATIN TAB.4Branchement Electrique Essais Regler HorloseEvacuation DES Eaux DE Condensation Langue Alarmes ET Analyse EN Panne TAB.5Advenue avec le numéro progressif d’alarme de A01 à A30 Panne Cause Solution Description DES Parametres ParametresRegulation Impression Modification DES Parametres Enregistrées en mémoire. On affiche Restore Default ParametresEntrees ET DES Sorties Installation DE L’IMPRIMANTEEntretien DU Tableau Électrique Systémes DE Contrôle ET Témoins Plaquette Schéma ÉlectriqueEcoulement Stockage DES DéchetsFiche Technique DU Refrigerant Inversion PorteManuel D’INSTALLATION Dimensions D’ENCOMBREMENT BCF22020 TAB.1a AnnexesCirculation air min Modèle Quantité air Cfm 79A