- INSTALLATION MANUAL -
TAB.5
FAULT | CAUSE | REMEDY |
No voltage on | No power supply | Restore power supply |
Anomalous stop | Blown fuse | Replace fuses |
| Loosened connections | Check connection fitting |
Compressor failure | High and | Ask for skilled assistance |
| switch on | Ask for skilled assistance |
| Clicker on | Ask for skilled assistance |
| Contactor failure | Ask for skilled assistance |
| Compressor thermal relay on |
|
The compressor is working but | Frosted evaporator | Open the door and carry out defrost cycle |
the cabinet is not cooling | No coolant inside the refrigerating | Ask for skilled assistance |
| system | Ask for skilled assistance |
| Delivery solenoid valve failure |
|
Evaporator fans are not working | Fan failure or | Ask for skilled assistance |
| Door micro failure | Ask for skilled assistance |
The cycle cannot start | Wrong cycle programming | Check time and temperature parameters |
AL High Press | High Pressure Switch | Qualified technician required |
AL Room Probe | Room Probe interrupted | Qualified technician required |
AL Evap Probe | Evap Probe interrupted | Qualified technician required |
AL Cond Probe | Cond Probe interrupted | Qualified technician required |
AL Needle Probe | Needle Probe interrupted | If a probe cycle is running, the cycle is |
|
| Qualified technician required |
AL Insert Needle | Needle Probe not inserted | Check the probe inserting cone |
High T Room | Room Temp above set value | If the temperature is not within the specified range, apply |
|
| to a qualified technician |
Low T Room | Room Temp below set value | If the temperature is not within the specified range, apply |
|
| to a qualified technician |
AL BlackOut | No power supply | When power is restored, check the max. temperature |
|
| reached inside the room |
AL Door Open | QC room door open | Close the door |
| Door micro faulty | Qualified technician required |