American Dynamics Appendix a ADCC0200/ADCC0300 VCR Reprogramming, Label Key Default Command

Page 45

Keyboard Installation and Operation

Appendix A: ADCC0200/ADCC0300 VCR Reprogramming

The ability to reprogram the RS232 commands, that are sent out when the unit is in RS485 mode with Direct Control enabled, has been added. The default commands are those applicable to the Direct Control and are shown in the second and third columns below:

Label

Key

Default Command

 

 

 

PLA

Play

<STX>FPL<ETX>

REV

Reverse

<STX>RPL<ETX>

 

 

 

PAU

Pause

<STX>PAU<ETX>

REW

Rewind

<STX>REW<ETX>

FWD

Fast Forward

<STX>FWD<ETX>

REC

Record

<STX>REC<ETX>

STP

Stop

<STX>STO<ETX>

DZM

Digital Zoom

<STX>SEA<ETX>

MEN

Menu

<STX>MEN<ETX>

INC

Increment

<STX>ISP<ETX>

DEC

Decrement

<STX>DSP<ETX>

ENT

Enter

<STX>ENT<ETX>

JLT

Joystick Left

<STX>ARL<ETX>

JRT

Joystick Right

<STX>ARR<ETX>

JUP

Joystick Up

<STX>ARU<ETX>

JDN

Joystick Down

<STX>ARD<ETX>

SLO

-

0x64

FST

-

0x14

PAR

Parity Change

8N1

In order to reprogram these commands, the SEARCH () key must be pressed within 5 seconds of entering the

Special Config menu (achieved by simultaneously pressing the SHIFT and CLEAR keys) following a reset. Note that they may only be reprogrammed if the keyboard is configured for RS485 mode with Direct Control enabled.

Once the above key sequence has been pressed, the reprogramming takes place using a terminal or emulator attached to the RS232 port of the keyboard (as shown below). The baud rate will be whatever was configured on the keyboard for RS232 mode (see Setting the Baud Rate on page 34).

37

Image 45
Contents ControlCenterTM Copyright Radio Frequency Emissions Electrical SafetyImmunity EU Conformance StatementSécurité électrique Émission de fréquences radioImmunité Déclaration de conformité UEElektrische Sicherheit FunkfrequenzemissionenImmunität EU-KonformitätserklärungSicurezza elettrica Emissioni in radiofrequenzaImmunità Dichiarazione di conformità UESeguridad eléctrica Emisión de radiofrecuenciaInmunidad Declaración de conformidad de la UEElektrische veiligheid Radiofrequentie-emissieImmuniteit Conformiteitsverklaring van de fabrikantAbout the ADCC0200 and ADCC0300 Keyboard Programming with the ADCC0200/ADCC0300 Keyboards About the ADCC0200 and ADCC0300 Keyboard Key FeaturesADCC0200 and ADCC0300 Keyboard Overview Joystick Page Feature Quick Reference Standard Matrix OperationsRS485 RS232 RS232 RS485 Matrix Menu OperationsDome Operations DirectSet Feature Connection and Setup Ancillary EquipmentMP-KMI Keyboard Matrix Interface Installation Precautions Keyboard Installation and Operation Default setting Multiple Keyboards on an RS485 NetworkTerminating/Biasing the RS485 Network Multiple Keyboards on an RS232 Network User Numbers and Passcodes Basic Operations Operate Mode ADCC0200 and ADCC0300Logging On to the System Logging Off from the SystemSelecting Monitors Keyboard DisplayCalling a Camera to View on a Monitor S01 M000 C0000S01 M013 C0000 S01 M013 C0032 Controlling a Camera’s Pan, Tilt and ZoomControlling the Camera Iris Controlling Camera FocusControlling Camera Flip Auto IrisCalling Presets Auto FocusS01 M001 C0001 Dome Camera DirectSet Running PatternsHolding a Tour Running ToursRestarting a Tour on Hold Stepping through a TourReversing a Tour Calling Salvos RS232 onlyStopping a Tour S01 M013Acknowledging Alarms Calling Views RS485 onlyAuxiliaries Enabling or Disabling the Keyboard Sounder Setting the Keyboard Display ContrastViewing Satellite Sites S03 M0001 C0001Operating a VCR or Digital Recorder Cancel VCR/DVR modeLocking and Unlocking a Camera RS232 only R0021 S01 M013 C0001Initiating F1 Key Commands RS232 only Telemetry Enable/Disable RS485 onlyExiting Program Mode RS232 only Entering Program Mode RS232 onlyProgramming with the ADCC0200/ADCC0300 Keyboards S01 M0001 C0001Matrix Menu Navigating Dome Camera Menus Dome Menu FunctionsSetting Presets Programming Dome PatternsDefining Patterns RS485 only Clearing Patterns RS485 only Initiating F2 Key Commands RS232 onlyDefining Patterns RS232 only Clearing Patterns RS232 onlyEntering the Special Configuration Menu Installer FunctionsSetting the Keyboard Address Setting the Number of Keyboard Retries Setting the Baud Rate Setting the Network Timeout PeriodTo Reset the Keyboard to its Factory Defaults Selecting RS485 or RS232 modeSelecting Auto Repeat or Make/Break Keypress Mode Disabling/Enabling the Sounder1234 Enter Passcode Setting the Passcode Program Lock FunctionAppendix a ADCC0200/ADCC0300 VCR Reprogramming Label Key Default CommandFollowing text should initially be shown on the teminal Monitor Arming Code Monitor Acronym Command Sequence Appendix B Monitor Arming CommandsProblem Check List Appendix C TroubleshootingAppendix D Specifications Index Keyboard Installation and Operation ADCC0200 and ADCC0300 Keyboard Installation and Operation ADCC0200 and ADCC0300 Keyboard Installation and Operation Please visit our website for more information