American Dynamics ADCC0300, ADCC0200 manual Appendix B Monitor Arming Commands

Page 47

Keyboard Installation and Operation

Appendix B: Monitor Arming Commands

Monitors are armed for alarm call up with codes that specify the following three parameters:

1.The display method (single, dual, or block monitors).

2.The queuing method (sequence or hold).

3.The clearance method (instant, auto, or manual).

To arm a monitor with an ADCC0300 keyboard:

1.Call the monitor to be armed.

2.Enter the monitor arming code number (see table).

3.Press the FUNCTION () key, press the F1 () key.

A keyboard operator can also program any monitor armed for instant or auto clearance, for clearance via manual override. Manual override is enabled or disabled after the arming code is programmed. If enabled, an "A" will appear after the three-letter acronym for the arming code that appears on the monitor status line.

When using the AD1024 matrix switcher/controller system, monitors can be armed through S3 system setup software with a PC interface, or through the AD1024 embedded software with an ADCC0300 keyboard. Following is a table of monitor arming codes and the commands that enable the codes.

Monitor Arming Code

Monitor Acronym

Command Sequence

 

 

 

Display Arming Status

see entries below

300, FUNCTION, F1

Single, Sequence, Instant

SSI

301, FUNCTION, F1

 

 

 

Single, Sequence, Auto

SSA

302, FUNCTION, F1

Single, Sequence, Manual

SSM

303, FUNCTION, F1

Single, Hold, Instant

SHI

304, FUNCTION, F1

Single, Hold, Auto

SHA

305, FUNCTION, F1

Single, Hold, Manual

SHM

306, FUNCTION, F1

Block, Sequence, Instant

BSI

307, FUNCTION, F1

Block, Sequence, Auto

BSA

308, FUNCTION, F1

Block, Sequence, Manual

BSM

309, FUNCTION, F1

Block, Hold, Instant

BHI

310, FUNCTION, F1

Block, Hold, Auto

BHA

311, FUNCTION, F1

Block, Hold, Manual

BHM

312, FUNCTION, F1

Dual, Hold, Instant

DHI/DSI*

313, FUNCTION, F1

Dual, Sequence, Instant

 

 

Dual, Hold, Auto

DHA/DSA*

314, FUNCTION, F1

Dual, Sequence, Auto

 

 

Dual, Hold, Manual

DHM/DSM*

315, FUNCTION, F1

Dual, Sequence, Manual

 

 

Disarm Monitor

 

316, FUNCTION, F1

Enable Monitor Override

 

317, FUNCTION, F1

Disable Monitor Override

 

318, FUNCTION, F1

*In dual display applications, the first three-letter acronym is displayed on the hold monitor. The second three-letter acronym is displayed on the sequence monitor.

39

Image 47
Contents ControlCenterTM Copyright EU Conformance Statement Electrical SafetyRadio Frequency Emissions ImmunityDéclaration de conformité UE Émission de fréquences radioSécurité électrique ImmunitéEU-Konformitätserklärung FunkfrequenzemissionenElektrische Sicherheit ImmunitätDichiarazione di conformità UE Emissioni in radiofrequenzaSicurezza elettrica ImmunitàDeclaración de conformidad de la UE Emisión de radiofrecuenciaSeguridad eléctrica InmunidadConformiteitsverklaring van de fabrikant Radiofrequentie-emissieElektrische veiligheid ImmuniteitAbout the ADCC0200 and ADCC0300 Keyboard Programming with the ADCC0200/ADCC0300 Keyboards About the ADCC0200 and ADCC0300 Keyboard Key FeaturesADCC0200 and ADCC0300 Keyboard Overview Joystick Page RS485 RS232 Feature Quick ReferenceStandard Matrix Operations RS232 RS485 Matrix Menu OperationsDome Operations DirectSet Feature MP-KMI Keyboard Matrix Interface Connection and SetupAncillary Equipment Installation Precautions Keyboard Installation and Operation Terminating/Biasing the RS485 Network Default settingMultiple Keyboards on an RS485 Network Multiple Keyboards on an RS232 Network Logging Off from the System Basic Operations Operate Mode ADCC0200 and ADCC0300User Numbers and Passcodes Logging On to the SystemS01 M000 C0000 Keyboard DisplaySelecting Monitors Calling a Camera to View on a MonitorS01 M013 C0000 S01 M013 C0032 Controlling a Camera’s Pan, Tilt and ZoomAuto Iris Controlling Camera FocusControlling the Camera Iris Controlling Camera FlipS01 M001 C0001 Calling PresetsAuto Focus Dome Camera DirectSet Running PatternsStepping through a Tour Running ToursHolding a Tour Restarting a Tour on HoldS01 M013 Calling Salvos RS232 onlyReversing a Tour Stopping a TourAuxiliaries Acknowledging AlarmsCalling Views RS485 only S03 M0001 C0001 Setting the Keyboard Display ContrastEnabling or Disabling the Keyboard Sounder Viewing Satellite SitesR0021 S01 M013 C0001 Cancel VCR/DVR modeOperating a VCR or Digital Recorder Locking and Unlocking a Camera RS232 onlyInitiating F1 Key Commands RS232 only Telemetry Enable/Disable RS485 onlyS01 M0001 C0001 Entering Program Mode RS232 onlyExiting Program Mode RS232 only Programming with the ADCC0200/ADCC0300 KeyboardsMatrix Menu Navigating Dome Camera Menus Dome Menu FunctionsDefining Patterns RS485 only Setting PresetsProgramming Dome Patterns Clearing Patterns RS232 only Initiating F2 Key Commands RS232 onlyClearing Patterns RS485 only Defining Patterns RS232 onlySetting the Number of Keyboard Retries Installer FunctionsEntering the Special Configuration Menu Setting the Keyboard AddressSetting the Baud Rate Setting the Network Timeout PeriodDisabling/Enabling the Sounder Selecting RS485 or RS232 modeTo Reset the Keyboard to its Factory Defaults Selecting Auto Repeat or Make/Break Keypress Mode 1234 Enter Passcode Setting the Passcode Program Lock FunctionAppendix a ADCC0200/ADCC0300 VCR Reprogramming Label Key Default CommandFollowing text should initially be shown on the teminal Monitor Arming Code Monitor Acronym Command Sequence Appendix B Monitor Arming CommandsProblem Check List Appendix C TroubleshootingAppendix D Specifications Index Keyboard Installation and Operation ADCC0200 and ADCC0300 Keyboard Installation and Operation ADCC0200 and ADCC0300 Keyboard Installation and Operation Please visit our website for more information