MGE UPS Systems 2000, 3000 VA user manual Connection modules, Fault tolerant, Hot swap Install

Page 7

1.2 Connection modules

Fault tolerant

1

1. Presentation

1 Socket for connection to AC-power source.

2 Outlets for direct connection to protected equipment.

3 Manual bypass switch.

4 Input terminal block with cable clamp.

2

5 Output terminal block with cable clamp.

Hot swap

Install

Different types of sockets available on Fault tolerant and Hot swap

connection modules:

3

 

AC input cord

Outlet sockets

Power cords to

 

 

 

 

equipment

1

USE

DIN plug,

4

USE outlets (16A)

 

 

2.5m cable,

 

 

 

 

 

 

 

 

 

 

IEC320C20 cable

 

 

 

 

 

 

 

 

 

5

DIN

DIN plug,

4

DIN outlets (16A)

 

 

 

2.5m cable,

 

 

 

2

 

IEC320C20 cable

 

 

 

 

BS

BS plug,

4

BS outlets (13A)

 

 

 

2.5m cable,

 

 

 

 

 

IEC320C20 cable

 

 

 

 

 

 

 

 

 

 

IEC

IEC320C20 plug

4

IEC320C13 outlets

2 x

 

 

(not supplied)

(10A) protected by

IEC320C13 plug,

 

 

 

10A circuit breaker

2.5m cable,

 

 

 

and 1 IEC320C20

IEC320C13 plug

 

 

 

outlet (16A)

 

 

 

 

 

 

 

 

NEMA

NEMA plug,

4

NEMA outlets

 

 

 

2.5m cable,

(15A / 250V)

 

3

 

IEC320C20 cable

 

 

 

 

 

 

 

 

 

 

SWITZERLAND

Swiss plug,

4

IEC320C13 outlets

2 x

 

 

2.5m cable,

(10A) protected by

IEC320C13 plug,

 

 

IEC320C20 cable

10A circuit breaker

2.5m cable,

5

 

 

and 1 IEC320C20

IEC320C13 plug

 

 

outlet (16A)

 

 

 

 

 

 

 

 

 

 

4

AUSTRALIA

AUSTRALIAN plug,

4 AUSTRALIAN

 

 

2.5m cable,

outlets (16A)

 

 

 

IEC320C20 cable

 

 

 

 

 

 

 

 

 

51033211EN/AC - Page 7

Image 7
Contents Pulsar EXtreme Introduction Foreword Using this documentPictograms Contents Glossary Index Failure of AC input power and operation on battery powerRack model PresentationPulsar EXtreme range Tower modelOutput terminal block with cable clamp Fault tolerantHot swap Install Connection modulesBack Options Battery extensions for UPS backup times of 66 minutesCLA Control panel Alarms Battery Load RemainingCD ROM with Solution Pac and UPS Driver softwares InstallationUnpacking and checks Rack model Rack mounting diagram with rails Installation of the rack versionConnection to the RS 232 communications port optional Installation of the communications-card optionTwo screws Securing and connecting the connection modulesConnection to the AC-power source Securing the connection modulesHot swap Always connect the earthing wire firstConnection of equipment to a terminal block Power and equipment connections Operation ON-LINE operating modeBargraph indications Start-upFailure of AC input power and operation on battery power On / OFF conditions tab Personalizable function Default settingPersonalization FunctionBy-pass tab Battery tabPersonalizable function Default setting Options Output tabShutdown Connected equipment is no longer supplied with powerTroubleshooting Maintenance26 51033211EN/AC Fault-tolerant connection module UPS replacementConnected equipment is again protected by the UPS Hot-swap and Install connection modules Press button 24 and wait 20 seconds Check that LED 21 is on Packing UPS recycling at the end of service lifeEnvironment This product has been designed to respect the environmentGlossary AppendicesStart on battery power InstallON-LINE mode Sleep modeIndex Battery34 51033211EN/AC