American Power Conversion
MX28B400
user manual
Specs
Install
Alarm Item
Controls and Indicators
Connecting the Cables
Warranty
LVD Reset
RJ45 Ethernet Connector
Battery Management
How to
Page 1
MX28B400
+24 Vdc Power System
With Network Management
User’s Manual
Page 1
Page 2
Image 1
Page 1
Page 2
Contents
Page
Table of Contents
Remote Monitoring
Revision Date Description
Revision History
General Precautions
Safety First
General Information
Introduction
2 MX28B-400 +24 Vdc System Wiring Diagram with Battery LVD
How to Use This Manual
Mechanical Installation
Installation
Unpacking Equipment
Room / Location
Ventilation
AC Power Connections
Planning the Battery installation
Battery Connections
Connecting the Cables
2 Battery Temperature Probe Installation
Battery Temperature Probe Installation
DC System Grounding
DC Circuit Breakers
DC Power Output Over-Current Protection
Breaker Part Number Adaptor Size Rating
Load Cable Size Considerations
Plug-in Circuit Breaker Installation
Circuit Breaker Connections 60-100 Amps
Circuit Breaker Connections 1 to 50 Amps
GMT Fuse Option
Monitoring and Relay Output Connections
Front Panel DB9 Connection
Smart Cable DB9 Connection
Relay Output Connections
RJ45 Ethernet Connector
NO-NC-C
External Alarm Input Connections
Initial Power-Up and Checkout
Rectifier Module Installation
Battery Maximum Recharge Rate default = 12A
System Parameters Verification/Adjustment
Full System Power Up
Technical Description
Operation
Rectifier Management
System Management
System Status and Alarm Reporting
System Output Capacity
System Voltage Control
Battery Charging and Protection
Battery Management
Battery Temperature Compensation
DC Distribution
Battery/Load Low Voltage Disconnect
Controls and Indicators
Front Panel User Interface
Parameter Locations, Descriptions, and Default Values
Status Alarms System Modules Batt PIN OEM
No Alarms
Alarm Item
Address
Switzer Av
22.00
Minor
Batt Max Rechm+
50 a
Comp Method m+
Comp Lknee
Comp TC
00mV
Hw Batt C Almm+
Fuse 1 Alm
Hw Batt T Almm+
Hw LVD Alm
LVD Reset
Disable
Lamp Test
LVD Option
Relay
Out-Rly
Out-Rly 1 Dly m+
Sec
Rect 1 CL
Rect CL Alm
Rect 1 Curr
24.9
Rect 1 Stdby
Rect Stdby Almm+
Store Cfg
Sys Current
26.7
Sys Temp
Sys Voltage
Test Maj Rly
Control Unit Menu Structure
Status Alarms
V e l C o n d L e v e l I r d L e v e l U r t h L e v e l
Sysout AP Alias
MOD Modrec EM Modules Batt Rect Conv CIR SET-ALM Param
MOD Modcir
MOD Modlvd MT LVD SET-ALM Param
Front Panel LED Indicators
External Alarm Inputs Input Relays
Alarm Outputs Output Relays
Remote Monitoring
Command and Monitoring Protocol
Description
Physical Connections
AC Input
Specifications
1MRF28H27BV Rectifiers
1MRF28H27BV50 Rectifiers
Rectifiers
DC Output with either Rectifier
Pscu
Power Shelf Control Unit
Environmental
Mechanical
Compliance
APC Worldwide Customer Support
Limited Product Warranty
Related pages
Displayed information for troubleshooting for Eclipse - Fujitsu Ten CD1000
Laserdisc Player Code List for RCA RCU500
Top
Page
Image
Contents