American Power Conversion MX28B400 user manual Revision History, Revision Date Description

Page 4

Revision History

Revision

Date

By

Description

990-1809 Rev 1

02 MAR, 2004

BET

Preliminary Release

 

 

 

 

 

 

 

 

 

 

 

 

Table of Figures

 

FIGURE 2.1-1 MX28B-400 +24 VDC POWER PLANT

2

FIGURE 2.1-2 MX28B-400 +24 VDC SYSTEM WIRING DIAGRAM WITH BATTERY LVD

3

FIGURE 3.4-1 BATTERY CABLE CONNECTION LOCATIONS

7

FIGURE 3.4-2 BATTERY TEMPERATURE PROBE INSTALLATION

8

FIGURE 3.5-1 DC GROUND CONNECTION POINT

9

FIGURE 3.6-1 DC DISTRIBUTION (FRONT COVER REMOVED)

10

FIGURE 3.6-2 CIRCUIT BREAKER KITS

11

FIGURE 3.6-3. INSTALLATION OF CIRCUIT BREAKERS

12

FIGURE 3.6-4 STANDARD LUG FOR 1 TO 50A BREAKERS

13

FFIGURE 3.6-5 ADAPTOR AND LUGS FOR 60-100 AMP BREAKERS

14

FIGURE 3.7-1 INTERFACE BOARD

15

FIGURE 3.7-2 OUTPUT RELAY CONNECTIONS

16

FIGURE 3.8-1 EXTERNAL ALARM INPUT DEFINITION

16

FIGURE 3.8-2 EXTERNAL ALARM INPUT CONNECTIONS

16

FIGURE 4.6-1 MENU TOP LINE

24

MX28B400 +24 VDC User’s Manual

Page iv

Image 4
Contents Page Table of Contents Remote Monitoring Revision History Revision Date DescriptionSafety First General PrecautionsIntroduction General Information2 MX28B-400 +24 Vdc System Wiring Diagram with Battery LVD How to Use This Manual Installation Mechanical InstallationUnpacking Equipment Room / LocationAC Power Connections VentilationPlanning the Battery installation Battery ConnectionsConnecting the Cables Battery Temperature Probe Installation 2 Battery Temperature Probe InstallationDC System Grounding DC Power Output Over-Current Protection DC Circuit BreakersBreaker Part Number Adaptor Size Rating Plug-in Circuit Breaker Installation Load Cable Size ConsiderationsCircuit Breaker Connections 1 to 50 Amps Circuit Breaker Connections 60-100 AmpsMonitoring and Relay Output Connections GMT Fuse OptionFront Panel DB9 Connection Smart Cable DB9 ConnectionRJ45 Ethernet Connector Relay Output ConnectionsExternal Alarm Input Connections NO-NC-CRectifier Module Installation Initial Power-Up and CheckoutSystem Parameters Verification/Adjustment Battery Maximum Recharge Rate default = 12AFull System Power Up Technical Description OperationRectifier Management System Status and Alarm Reporting System ManagementSystem Output Capacity System Voltage ControlBattery Management Battery Charging and ProtectionBattery Temperature Compensation DC DistributionBattery/Load Low Voltage Disconnect Controls and IndicatorsFront Panel User Interface Status Alarms System Modules Batt PIN OEM Parameter Locations, Descriptions, and Default ValuesAlarm Item No AlarmsAddress Switzer AvMinor 22.00Batt Max Rechm+ 50 aComp Lknee Comp Method m+Comp TC 00mVFuse 1 Alm Hw Batt C Almm+Hw Batt T Almm+ Hw LVD AlmDisable LVD ResetLamp Test LVD OptionOut-Rly RelayOut-Rly 1 Dly m+ SecRect CL Alm Rect 1 CLRect 1 Curr 24.9Rect Stdby Almm+ Rect 1 StdbyStore Cfg Sys CurrentSys Temp 26.7Sys Voltage Test Maj RlyStatus Alarms Control Unit Menu StructureV e l C o n d L e v e l I r d L e v e l U r t h L e v e l Sysout AP Alias MOD Modrec EM Modules Batt Rect Conv CIR SET-ALM Param MOD Modcir MOD Modlvd MT LVD SET-ALM Param Front Panel LED Indicators Alarm Outputs Output Relays External Alarm Inputs Input RelaysCommand and Monitoring Protocol Remote MonitoringDescription Physical ConnectionsSpecifications AC Input1MRF28H27BV Rectifiers 1MRF28H27BV50 RectifiersDC Output with either Rectifier RectifiersPower Shelf Control Unit PscuEnvironmental MechanicalCompliance APC Worldwide Customer Support Limited Product Warranty